Disposable monopolar electrosurgery electrode with 70 mm needle tip in AISI stainless steel (Ø 0.65 mm), universal 2.38 mm (3/32″) shaft with anti-rotation hexagonal lock — Ref. F4048 · Box of 24 sterile units

29,50 €

Disposable monopolar electrosurgery electrode with 70 mm needle tip in medical-grade stainless steel: it concentrates radiofrequency current at a minimal point of contact for cutting, fine dissection and precision haemostasis, with minimal lateral thermal damage. Mounted on a universal 2.38 mm (3/32″) shaft with anti-rotation hexagonal lock, it is compatible with the vast majority of pencils and electrosurgical units on the market (Valleylab-type connector and compatible). Sterilised by ethylene oxide, single-use, latex-free and with anti-shock insulating handle (HIPS). Ref. F4048 · SKU 0565070 — price per box of 24 units with individual heat-sealed packaging.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
0565070

Description

1. Commercial Introduction

The disposable monopolar electrosurgery electrode Ref. F4048 is the consumable of choice when high-precision cutting and coagulation is required with a short, manageable reach. Its 70 mm needle tip in AISI stainless steel concentrates radiofrequency energy at a minimal contact point, allowing fine incisions, precise dissection and targeted haemostasis with the best cost per procedure.

Each box includes 24 sterile single-use units, ready to open at the time of surgery: a safe solution that eliminates the risk of cross-contamination and the costs of cleaning and re-sterilisation. Immediate stock available for hospitals, clinics, ambulatory major surgery centres and minor surgery clinics, with B2B supply throughout Spain.

2. Technical explanation and operation

The F4048 electrode acts as the active electrode of a monopolar electrosurgery system: the high-frequency current generated by the electrosurgical unit (ESU) travels through the pencil to the needle tip and concentrates at a minimal contact point, producing the desired surgical effect—cutting, coagulation or mixed—and returning through the neutral (dispersive) plate placed on the patient.

  • Needle tip Ø 0.65 mm: maximum energy concentration for fine incisions, precision dissection and targeted haemostasis of small vessels, with minimal lateral thermal injury.
  • AISI stainless steel: reliable electrical conductivity and consistent performance throughout the procedure.
  • 70 mm length (±3%): contained reach, with great control and stability, ideal for ambulatory procedures and superficial approaches.
  • 2.38 mm (3/32″) shaft with hexagonal anti-rotation lock: universal fixing standard, compatible with the vast majority of pencils and electrosurgical units on the market (Valleylab type and compatible), without the need for adapters.
  • Anti-shock insulating handle (HIPS): insulates and protects the professional during surgical practice.
  • Sterile single-use: sterilised by ethylene oxide (EO) and latex-free, eliminates the risk of cross-contamination.

3. Technical Specifications

Disposable electrosurgery electrode manufactured from medical-grade stainless steel with an integrated needle tip, guaranteeing optimal and consistent performance in every use.

Specification Detail
Reference / SKU F4048 · 0565070
Product type Disposable active electrode for monopolar electrosurgery
Tip shape Precision needle
Needle diameter 0.65 mm
Total length 70 mm (±3%)
Electrode material AISI stainless steel
Shaft diameter 2.38 mm (3/32″) — universal connection
Locking system Hexagonal anti-rotation
Insulation / handle HIPS (high-impact polystyrene, anti-shock protection)
Compatibility Handpieces with universal connection 2.38 mm (3/32″), Valleylab type and compatible
Sterilisation Ethylene oxide (EO)
Sterility Sterile, individually heat-sealed paper/polyethylene package
Presentation Box of 24 units
Use Single-use medical device
Latex Latex-free
Shelf life / storage 4 years from date of manufacture · 0–50 °C · HR 20–80 %
Regulatory classification Medical device Class IIb · CE marking (Notified Body 2797) · Directive 93/42/EEC

Variants of the same family (stainless steel, 2.38 mm shaft, box of 24 units)

Reference Tip shape Tip size Length Insulation
F4046 Blade (knife) Thickness 0.50 mm · width 2.3 mm 70 mm HIPS
F4053 Blade (knife) Thickness 0.50 mm · width 2.3 mm 100 mm HIPS
F4050 Blade (knife) Thickness 0.50 mm · width 2.3 mm 153 mm HIPS
F4048 (this product) Needle Ø 0.65 mm 70 mm HIPS
F4052 Needle Ø 0.75 mm 152 mm HIPS
F4049 Ball (sphere) Ø 2 mm 54 mm PE
F4044 Ball (sphere) Ø 4 mm 70 mm HIPS · PE
F4067 Ball (sphere) Ø 4 mm 156 mm HIPS · PE
F4067/5 Ball (sphere) Ø 5 mm 157 mm HIPS · PE

Compatibility note: verify that your pencil accepts a 2.38 mm (3/32″) shaft with hexagonal lock; the vast majority of electrosurgical units on the market (Valleylab, ConMed, Bovie, Erbe and compatible) accept it.

4. Equivalences and Cross-References

The reference F4048 is verified in the manufacturer’s official public catalogue (sterile disposable stainless steel electrode, 70 mm needle, box of 24 units). No official cross-reference table from the manufacturer has been found in public sources that validates an exact 1:1 equivalence with other brands. The following rows are functional comparisons verified against official catalogues and the GUDID/FDA regulatory database, and should be treated as comparable at category level, not interchangeable 1:1 without validation from the technical department.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Bovie / Aspen Surgical (USA) Bovie® Needle Electrode, standard stainless steel needle, single-use and sterile ES02 (needle 2 3/4″ / 7 cm ≈ 70 mm, shaft 3/32″ / 2.3 mm, box of 25) Comparable by category (not interchangeable 1:1) Sterile disposable needle electrode with universal 3/32″ (2.3–2.38 mm) shaft and handle with grip insulation (safety grip); length practically identical (7 cm vs 7 cm). Differ: presentation (25 units vs 24). Code and attributes verified on Aspen Surgical’s official website and GUDID/FDA.
Medtronic / Valleylab (USA) Valleylab™ stainless steel electrode, needle configuration, single-use and sterile E1552 (needle 7.2 cm / 2.84″, shaft 3/32″, box of 150) Comparable by category (not interchangeable 1:1) Single-use stainless steel monopolar needle electrode with standard 3/32″ (2.38 mm) shaft and 2.8 cm active tip; length very similar (7.2 cm vs 7 cm). Differ: exact length and presentation (box of 150 vs 24). Code and attributes verified on Medtronic’s official website and GUDID/FDA (Covidien LP).
ConMed (USA) Needle Electrode with Extended Insulation, Hex Hub (needle with extended insulation and hexagonal hub) 138105 (box of 40) Comparable by category (not interchangeable 1:1) Single-use stainless steel needle electrode, sterile, with hexagonal hub and 3/32″ (2.38 mm) shaft; incorporates extended shaft insulation. Differ: length, insulation and presentation (40 units vs 24). Code and attributes verified in authorised distribution and GUDID/FDA (ConMed Corporation).

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Before any substitution, check field by field: total length (70 mm), needle diameter (0.65 mm), shaft diameter (2.38 mm / 3/32″), fixation system (hexagonal lock), material (AISI stainless steel), sterility and presentation. The third-party codes cited have been verified in public sources and correspond to electrodes of the same category, not to certified 1:1 equivalents.

5. Selection tips and variants of interest

The F4048 needle tip is indicated for precision dissection, fine incisions and targeted haemostasis in superficial-field procedures: dermatological surgery, minor surgery, biopsies and open surgery with reduced access, with great control thanks to its 70 mm length.

  • Cost per procedure: if no non-stick effect is required, this stainless steel reference is the series option; if you prefer non-stick, the same 70 mm needle is available with Teflon coating (F4048/TEF) or titanium coating (F4048T), and with insulating tungsten sleeve (F4048/TU, 65 mm).
  • Protection of adjacent tissues: the F4048/S version (69 mm) incorporates an insulating sleeve for delicate access.
  • Greater reach: the long stainless steel series offers the F4052 needle (152 mm); the blades F4046 (70 mm), F4053 (100 mm) and F4050 (153 mm) and the ball electrodes F4044 (Ø 4 mm) and F4067 (Ø 4 mm) complete the range for cutting and coagulation of surfaces.

Always verify that your pencil or electrosurgical unit accepts a 2.38 mm (3/32″) shaft: the vast majority of Valleylab, ConMed, Bovie, Erbe and compatible equipment accepts it. This is a single-use product: do not re-sterilise or reuse. For institutional volumes, supply agreements or tenders, consult our technical-commercial department.

Additional information

Reference

F4048

Product type

Disposable active electrode for monopolar electrosurgery

Tip shape

Precision needle

Needle diameter

0.65 mm

Total length

70 mm (±3%)

Material

AISI stainless steel

Locking system

Hexagonal anti-rotation

Handle insulation

HIPS (high-impact polystyrene, anti-shock protection)

Compatibility

Handpieces with universal connection 2.38 mm (3/32"), Valleylab type and compatible

Sterilisation

Ethylene oxide (EO)

Sterility

Sterile, individually heat-sealed paper/polyethylene package

Presentation

Box of 24 units

Use

Single-use medical device

Shelf life

4 years from the date of manufacture

Storage

0–50 °C · relative humidity 20–80 %

Regulatory classification

Medical device Class IIb · CE marking (Notified Body 2797) · Directive 93/42/EEC

Manufacturer reference

F4048

Electrode material

AISI stainless steel

Shaft diameter

2.38 mm (3/32") — universal connection

Fixation system

Hexagonal anti-rotation lock

Latex

Latex-free

Reviews

There are no reviews yet.

Be the first to review “Disposable monopolar electrosurgery electrode with 70 mm needle tip in AISI stainless steel (Ø 0.65 mm), universal 2.38 mm (3/32″) shaft with anti-rotation hexagonal lock — Ref. F4048 · Box of 24 sterile units”

Your email address will not be published. Required fields are marked *