Description
1. Introduction
We offer you the evoline electrode handles (HF pencil) from REGER Medizintechnik GmbH (Germany), the reusable grip on which the active electrodes of your high-frequency (HF) surgery system are mounted. With integrated cable and 2 buttons (cut and coagulation), this handle eliminates intermediate connections, simplifies assembly in the operating theatre and guarantees stable transmission of current to the electrode. Its reusable design withstands up to 300 re-sterilisation cycles, reducing the cost per procedure compared with disposable pencils. It is the ideal choice for operating theatres, major ambulatory surgery, minor surgery clinics, gynaecology, dermatology and colposcopy.
2. Technical explanation
In monopolar electrosurgery, the electrosurgical generator (ESU) sends high-frequency current through the electrode handle to the active electrode, which concentrates the current density at the tip to cut, coagulate or combine both effects; the circuit is closed through the dispersive neutral plate. This evoline handle secures the electrode in the housing for shafts of Ø 4 and 2.4 mm and distributes the energy through the integrated cable, whose connector adapts directly to each generator according to the reference chosen. The hexagonal anti-twist protection (hexagon anti-twist protection) of the Ø 4 and 2.4 mm shafts prevents accidental rotation of the tip during the surgical procedure, ensuring a stable and safe orientation of the electrode at all times. The 2 buttons allow alternating between cutting and coagulation without releasing the grip, and its reusable construction maintains consistent cutting and coagulation performance cycle after cycle.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Brand / Manufacturer | REGER Medizintechnik GmbH (Germany) |
| Product type | evoline electrode handle (HF pencil) with integrated cable |
| System | High-frequency (HF) monopolar electrosurgery |
| Compatible shaft diameter | 4 mm and 2.4 mm |
| Buttons | 2 (cut and coagulation) |
| Fixation system | Hexagonal anti-twist protection |
| Type of use | Reusable |
| Re-sterilisation | Up to 300 cycles |
| Maximum voltage (Umax) | 4.3 kVp |
| Integrated cable lengths | 3 m and 5 m (depending on reference) |
| Units per pack | 1 |
| Commercialisation | Under quotation |
Manufacturer’s specifications
| Characteristic | Value |
|---|---|
| Maximum voltage (Umax) | 4.3 kVp |
Available references
| REGER reference | Length | Connection to the generator | Shaft | Units per pack | Compatible with |
|---|---|---|---|---|---|
| 92746 | 3 m | Erbe, Storz | 4 mm | 1 | Erbe, Storz |
| 92747 | 5 m | Erbe, Storz | 4 mm | 1 | Erbe, Storz |
| 92752 | 3 m | Erbe T-Serie | 4 mm | 1 | Erbe T-Serie |
| 92741 | 3 m | Martin, Berchtold, Integra | 4 mm | 1 | Martin, Berchtold, Integra |
| 92743 | 5 m | Martin, Berchtold, Integra | 4 mm | 1 | Martin, Berchtold, Integra |
| 92740 | 3 m | Valleylab, Int. Models 3 Pin | 4 mm | 1 | Valleylab, Int. Models 3 Pin |
| 92745 | 5 m | Valleylab, Int. Models 3 Pin | 4 mm | 1 | Valleylab, Int. Models 3 Pin |
| 92750 | 3 m | Erbe, Storz | 2.4 mm | 1 | Erbe, Storz |
| 92751 | 5 m | Erbe, Storz | 2.4 mm | 1 | Erbe, Storz |
| 92749 | 3 m | Martin, Berchtold, Integra | 2.4 mm | 1 | Martin, Berchtold, Integra |
| 92748 | 5 m | Martin, Berchtold, Integra | 2.4 mm | 1 | Martin, Berchtold, Integra |
| 92742 | 3 m | Valleylab, Int. Models 3 Pin | 2.4 mm | 1 | Valleylab, Int. Models 3 Pin |
| 92744 | 5 m | Valleylab, Int. Models 3 Pin | 2.4 mm | 1 | Valleylab, Int. Models 3 Pin |
4. Equivalences and Cross-References
References 92746, 92747, 92752, 92741, 92743, 92740, 92745, 92750, 92751, 92749, 92748, 92742 and 92744 are the original catalogue designations of REGER Medizintechnik for evoline electrode handles with integrated cable; at Cahnos they are marketed under the family RGR-MANGO-EVOLINE (base SKU) with the RGR- prefix per reference. A manufacturer-validated 1:1 equivalence table with handles of other brands is not available; reusable electrode handles from other manufacturers (with a 4 mm or 2.38 mm / 3/32″ shaft) may be comparable by category, but must be validated field by field (shaft diameter, generator connector and fixation system) before any substitution. Within the same HF electrosurgery system from REGER, the complementary families are available: PREMIUM electrode handles with detachable cable (base SKU RGR-MANGO-PREMIUM), PREMIUM handles with integrated cable (RGR-MANGO-PREMIUM-INTEGRADO) and handles without buttons (RGR-MANGO-SIN-BOTONES), as well as the full range of reusable electrodes – loop, ball, needle, blade, spatula, lancet and conisation – that fit onto these shafts.
5. Selection tips and variants of interest
Select the reference according to the shaft diameter of your electrodes (4 mm or 2.4 mm) and the connection of your generator. For Ø 4 mm shafts: refs. 92746 and 92747 (Erbe, Storz; 3 and 5 m), 92752 (Erbe T-Serie; 3 m), 92741 and 92743 (Martin, Berchtold, Integra; 3 and 5 m) and 92740 and 92745 (Valleylab 3 Pin; 3 and 5 m). For Ø 2.4 mm shafts: refs. 92750 and 92751 (Erbe, Storz), 92749 and 92748 (Martin, Berchtold, Integra) and 92742 and 92744 (Valleylab 3 Pin), in lengths of 3 and 5 m. Choose the 5 m length if the generator is far from the operating table, or the 3 m length for more contained cable management. After each use, subject the handle to sterilisation following the recommended cycle (up to 300 re-sterilisations) and periodically inspect the integrated cable and connection points. For B2B conditions, tenders or volume configurations, consult your technical-commercial advisor at Cahnos.





Reviews
There are no reviews yet.