We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable monopolar electrosurgery electrode, 70 mm needle with non-stick Teflon (PTFE) coating, universal shaft 2.38 mm (3/32″), sterile — Ref. F4048/TEF · Box of 24 units

103,20 €

Disposable monopolar electrosurgery electrode with a 70 mm needle tip and non-stick Teflon (PTFE) coating: precision cutting and coagulation with minimal carbonisation and without tissue adhering to the tip. Manufactured in AISI stainless steel, fitted with a universal shaft of 2.38 mm (3/32″) compatible with virtually all pencils and electrosurgical units on the market (Valleylab-type connector and compatible), without the need for adapters. Sterilised by ethylene oxide, single-use and latex-free, indicated for precision dissection, dermatology, minor surgery and spot haemostasis. Ref. F4048/TEF · Price per box of 24 units with individual heat-sealed packaging.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
F4048/TEF

Description

1. Commercial Introduction

The disposable electrosurgery electrode Ref. F4048/TEF is the reference consumable when high-precision cutting and coagulation with minimal tissue adhesion are required. Its 70 mm Teflon (PTFE)-coated needle glides cleanly over the surgical bed, reduces charred eschar formation and avoids interruptions to clean the tip during the procedure. It is supplied in a box of 24 units, single-use, sterile and with individual heat-sealed packaging: the most hygienic and cost-effective solution for hospitals, clinics, day surgery centres and minor surgery practices, with stock available for immediate B2B supply.

2. Technical explanation and operation

In a monopolar electrosurgery system, the electrosurgical generator (ESU) sends high-frequency current through the pencil to the active electrode —this F4048/TEF needle—, which concentrates the energy at the point of minimal contact with the tissue; the circuit is closed via the neutral (dispersive) plate placed on the patient. Depending on the selected waveform, the predominant effect is cutting, coagulation or mixed.

  • Needle tip: maximum energy concentration for fine incisions, precise dissection and pinpoint haemostasis of small vessels, with minimal lateral thermal injury.
  • Teflon (PTFE) coating: anti-adherent effect that minimises adhesion of slough and carbonisation, maintains conductivity and extends tip performance without frequent cleaning.
  • Shaft of 2.38 mm (3/32″) with anti-rotation hex lock: universal fixing standard, compatible with virtually all pencils and electrosurgical units on the market (Valleylab type and compatible), without the need for adapters.
  • Disposable and sterile: sterilised by ethylene oxide (EO), single-use, eliminates the risk of cross-contamination and the costs of cleaning and re-sterilisation.

3. Technical Specifications

Specification Detail
Reference / SKU F4048/TEF
Product type Disposable monopolar electrosurgery electrode
Length 70 mm
Coating Non-stick Teflon (PTFE)
Tip type Needle
Electrode material AISI stainless steel with Teflon (PTFE) coating
Shaft diameter 2.38 mm (3/32″) — universal standard
Fixation system Universal 2.38 mm (3/32″) receptacle with hexagonal anti-rotation lock
Compatibility Pencils and electrosurgical scalpels with 2.38 mm (3/32″) receptacle, Valleylab, ConMed, Bovie, Erbe and compatible types
Use Disposable, single-use
Sterility Sterile, individually heat-sealed packaging
Sterilisation Ethylene oxide (EO)
Latex Latex-free
Presentation Box of 24 units
Shelf life / storage 4 years from date of manufacture · 0–50 °C · relative humidity 20–80 %
Classification Electrosurgery medical device, class IIb · CE marking (Directive 93/42/EEC, notified body 2797)

Variants of the same family (Teflon coating, 2.38 mm shaft):

Reference Length Shape
F4044/TEF 70 mm Sphere Ø 4 mm
F4046/TEF 70 mm Blade
F4046S/TEF 70 mm (65 mm sleeve) Blade with insulating sleeve
F4048/TEF (this product) 70 mm Needle
F4048S/TEF 70 mm (65 mm sleeve) Needle with insulating sleeve
F4050/TEF 150 mm Blade
F4050S/TEF 150 mm (sleeve 145 mm) Blade with insulating sleeve
F4052/TEF 150 mm Needle
F4053/TEF 100 mm Blade
F4053S/TEF 100 mm (95 mm sleeve) Blade with insulating sleeve
F4067/TEF 150 mm Sphere Ø 4 mm

Note: verify that your pencil accepts a shaft of 2.38 mm (3/32″); virtually all electrosurgical units on the market (Valleylab, ConMed, Bovie, Erbe and compatible) accept it.

4. Equivalences and Cross-References

No official cross-reference table from the manufacturer has been found in public sources that validates an exact 1:1 equivalence of this electrode with those of other brands. The following rows are functional comparisons verified against official manufacturer catalogues, authorised distribution and the GUDID/FDA regulatory database, and should be treated as comparable at category level, not interchangeable 1:1 without validation by the technical department.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Prima Medical (United Kingdom) NonStick needle electrode, PTFE-coated, 70 mm needle PMS 2922 (pack of 10) Comparable by category (not interchangeable 1:1) Same needle length (70 mm) and anti-adherent PTFE (non-stick) coating; they differ in presentation (pack of 10 vs. box of 24) and manufacturer. Code and attributes verified in the official Prima Medical catalogue (distributed by Eurosurgical and Balmer Medical).
Prima Medical (United Kingdom) NonStick needle electrode with shielded tip, PTFE-coated, 70 mm needle PMS 2972 (pack of 10) Comparable by category (not interchangeable 1:1) Same 70 mm needle with anti-adherent PTFE coating; incorporates tip insulation, equivalent to a short sleeve. They differ in insulation, presentation (pack of 10) and manufacturer. Code and attributes verified in the official Prima Medical catalogue.
Bovie / Aspen Surgical (USA) Resistick II™ Coated Standard Needle Electrode, standard PTFE-coated needle, 2.75″ (6.98 cm) ES02T (box of 12) Comparable by category (not interchangeable 1:1) Virtually identical length (69.8 mm vs. 70 mm), standard straight needle with anti-adherent PTFE coating type Resistick II and standard 3/32″ (≈2.3 mm) shaft; they differ in presentation (box of 12 vs. 24) and manufacturer. Code and attributes verified in GUDID/FDA (Class II, sterile) and the manufacturer’s website.
Bovie / Aspen Surgical (USA) Resistick II™ Coated Extended Needle Electrode, PTFE-coated extended needle, 4″ (10.16 cm) ES56T (box of 12) Comparable by category (not interchangeable 1:1) Same anti-adherent PTFE coating and single-use needle concept with standard 3/32″ shaft; they differ in needle length (101.6 mm vs. 70 mm) and presentation (box of 12 vs. 24). Code and attributes verified in GUDID/FDA (Class II, sterile) and the manufacturer’s catalogue.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Before any substitution, check field by field: needle length (70 mm), coating (Teflon/PTFE), material (AISI stainless steel), shaft diameter (2.38 mm / 3/32″), fixing system (anti-rotation hex lock), sterility and presentation. The third-party codes cited have been verified in public sources and correspond to electrodes of the same category, not certified 1:1 equivalents. As homologous families in the sector for functional comparison purposes (without a validated official table) are the NonStick from Prima Medical, the Resistick II line from Aspen Surgical / Bovie and the needle electrodes from Medtronic (Valleylab) and ConMed; always verify material, coating and dimensions in the manufacturer’s data sheet before substituting.

5. Selection tips and variants of interest

The 70 mm needle of the F4048/TEF is indicated for precision dissection, fine incisions and pinpoint haemostasis in open surgery, dermatology, minor surgery and medium-depth surgical fields. If you need to protect adjacent tissues in delicate approaches, the reference F4048S/TEF offers the same 70 mm needle with Teflon coating and 65 mm insulating sleeve; if greater reach is required while retaining the coating, the F4048S/TEF100 (100 mm) and F4052/TEF (150 mm) extend the working radius. For cutting, the Teflon family is completed by the blades F4046/TEF (70 mm), F4053/TEF (100 mm) and F4050/TEF (150 mm), also available with insulating sleeve (F4046S/TEF, F4053S/TEF and F4050S/TEF); for contact coagulation, with the balls F4044/TEF (70 mm) and F4067/TEF (150 mm). If maximum tip durability is a priority, the version F4048/TU provides tungsten coating. Always verify that your pencil accepts a 2.38 mm (3/32″) shaft with hex lock: virtually all electrosurgical units from Valleylab, ConMed, Bovie, Erbe and compatible accept it. This is a single-use product: do not re-sterilise or reuse. For institutional volumes, supply agreements or tenders, consult our technical-commercial department.

Additional information

Product type

Disposable monopolar electrosurgery electrode

Coating

Non-stick Teflon (PTFE)

Tip shape

Needle

Material

AISI stainless steel

Shaft diameter

2.38 mm (3/32")

Fixation system

Universal 2.38 mm receptacle with hexagonal anti-rotation lock

Compatibility

Pencils and electrosurgical scalpels with 2.38 mm (3/32") receptacle, Valleylab, ConMed, Bovie, Erbe type and compatible

Use

Disposable, single-use

Sterility

Sterile, individual packaging

Presentation

Box of 24 units

Classification

Class IIb · CE marking (Directive 93/42/EEC, notified body 2797)

Sterilisation

Ethylene oxide (EO), individual heat-sealed packaging

Shelf life

4 years from the date of manufacture

Longitud

7 cm

Latex

Latex-free

Reviews

There are no reviews yet.

Be the first to review “Disposable monopolar electrosurgery electrode, 70 mm needle with non-stick Teflon (PTFE) coating, universal shaft 2.38 mm (3/32″), sterile — Ref. F4048/TEF · Box of 24 units”