Disposable monopolar electrosurgery handpiece (pencil) KIRKY – 3-pin Valleylab-type connector for electrodes Ø 2.4 mm, CUT/COAG buttons, blade electrode and 3.20 m cable, sterile – Box of 50 units (Ref. 30549)

203,30 €

Single-use monopolar electrosurgery handpiece (pencil), model KIRKY (ref. 30549), with 3-pin Valleylab-type connector and “click” buttons for cut (CUT) and coagulation (COAG). Accepts electrodes of Ø 2.4 mm and includes a blade electrode and a 3.20 m cable. Sterile presentation in a box of 50 units. Compatible with Diatermo MB mono-bipolar diathermy units (80, 120, 122, 132, 160, 200, 240, 300, 380, 400) and with most electrosurgical units on the market: Valleylab, Erbe, Conmed, Bovie, Martin, Eschmann, among others. Class II B medical device. For large orders, you can request a quote.

Sales unit: caja de 50
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM30549

You will also find it in

Description

1. Product Presentation

The KIRKY handpiece (ref. 30549, SKU Cahnos GM30549) is the single-use monopolar electrosurgery pencil that your operating theatre team needs to achieve clean cuts and reliable haemostasis in every procedure. Presented in a box of 50 sterile, ready-to-use units, it is the ideal supply solution for hospitals, clinics, ambulatory surgery centres, dermatology practices and purchasing groups seeking safety, stock turnover and an optimised cost per procedure.

2. Technical explanation

In a monopolar electrosurgery system, the high-frequency current generated by the electrosurgical unit travels through the pencil cable to the active electrode, concentrating at the point of contact with the tissue to produce the desired surgical effect (cut or coagulation), with return through the patient’s neutral plate (dispersive electrode). This KIRKY handpiece incorporates two buttons with a “click” system that allow the cut (CUT) and coagulation (COAG) functions to be selected and activated directly from the operating field, without having to release the instrument. It is supplied with a blade electrode and a 3.20 m cable. As it is a sterile single-use product, it eliminates the risks of cross-contamination and the costs associated with cleaning and re-sterilising reusable instruments.

3. Technical Specifications

Characteristic Specification
Manufacturer GIMA
Manufacturer reference 30549
SKU Cahnos GM30549
Product type Single-use monopolar electrosurgery handpiece (pencil)
Number of pins / connector 3 pins, Valleylab-type connector
Supported electrode diameter Ø 2.4 mm
Actuation “Click” buttons for CUT (cut) and COAG (coagulation)
Included electrode Blade electrode
Cable length 3.20 m
Sterility Sterile, single-use
Sales unit Box of 50 units (box of 50 pcs)
Device type Medical device (Medical device)
Device class II B
CND K0201010501
GMDN 44681
EAN 8033003264188

Compatibility

3-pin Valleylab-type connector, compatible with all Diatermo MB mono-bipolar diathermy units (80, 120, 122, 132, 160, 200, 240, 300, 380, 400) and with most electrosurgical units on the market: Aspen Lab, ES Generator, EMC Statome, Danieli, Braun, Berchtold, Ohmeda, Ritter, Conmed, Eschmann, Bovie, Martin, Kontron, Bard, Birtcher 771, Cobi, Valleylab, Led, Erbe.

4. Equivalences and Cross-References

No official equivalence table validated by the manufacturer has been found in reliable sources that would allow a 1:1 substitution with handpieces from other brands. Compatibility is based on the 3-pin Valleylab-type connection standard, the electrode shaft diameter (Ø 2.4 mm) and the button activation system. Within the ecosystem, this MB Kirky handpiece (30549) is the pencil included in the MB 120T TOUCH diathermy unit (ref. 30706) and shares a platform with the single-use ROCKER handpiece (ref. 30544), as well as with the MB waterproof footswitch (ref. 30577). To validate substitutions in mixed equipment fleets or tenders, please consult our technical-commercial department.

Available references

Reference Description Sales unit
GM30549 Single-use KIRKY MB handpiece – Sterile, with CUT/COAG buttons, 3-pin Valleylab-type connector, blade electrode and 3.20 m cable Box of 50 units

5. Selection tips and variants of interest

Check that your electrosurgical unit has a 3-pin Valleylab-type monopolar socket: this handpiece fits directly into Diatermo MB mono-bipolar units and most generators on the market with this connection standard. Also confirm the active electrode diameter (Ø 2.4 mm); this pencil is supplied with a blade electrode so you can start working immediately. If you prefer a rocker activation, the range offers the ROCKER handpiece (ref. 30544); if your unit uses a 1-pin (4 mm) connection for Diatermo 50, 80, 106 and 108, please consult the single-use Kirky handpieces (ref. 30517) or the autoclavable ones (refs. 30515 and 30519). As it is a sterile single-use product, do not re-sterilise or reuse the units and respect the integrity of the packaging until the time of the procedure. For institutional volumes, operating theatre supplies or tenders, contact our technical-commercial team for special conditions and product documentation.

Additional information

Manufacturer reference

30549

Product type

Single-use monopolar electrosurgery handpiece (pencil)

Connection type

3 pins, Valleylab-type connector

Electrode diameter

Ø 2.4 mm

Actuation

'Click' buttons for CUT (cut) and COAG (coagulation)

Included electrode

Blade electrode

Cable length

3.20 m

Sterility

Sterile, single-use

Presentation

Box of 50 units

Device type

Medical device (Medical device)

CND code

K0201010501

GMDN code

44681

EAN

8033003264188

Compatibility

Diatermo MB (80, 120, 122, 132, 160, 200, 240, 300, 380, 400) and most electrosurgical units on the market: Valleylab, Erbe, Conmed, Bovie, Martin, Eschmann, among others

Presentacion

Box of 50

Tipo dispositivo

Medical device

Clase sanitaria

II b

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityMultilingüe PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesDownload PDF

Reviews

There are no reviews yet.

Be the first to review “Disposable monopolar electrosurgery handpiece (pencil) KIRKY – 3-pin Valleylab-type connector for electrodes Ø 2.4 mm, CUT/COAG buttons, blade electrode and 3.20 m cable, sterile – Box of 50 units (Ref. 30549)”

Your email address will not be published. Required fields are marked *