Description
1. Product Presentation
The reusable electrosurgery electrode Ref. F4045/20 is the active tip your operating theatre needs for reliable, reproducible and precise coagulation in every procedure. Its Ø4 mm sphere concentrates high-frequency energy on a rounded surface that allows working on soft tissue, small vessels and bleeding beds with control, less carbonisation and reduced lateral thermal damage compared with needle or blade tips. The 20º angle facilitates haemostasis in lateral accesses and irregularly shaped fields without straining the surgeon’s wrist, while the 156 mm length offers a wide reach in deep surgical fields.
Being reusable and autoclavable, the same electrode can be used for multiple sterilisation cycles with consistent performance, significantly reducing the cost per procedure in hospitals, private clinics, minor surgery practices and ambulatory surgery centres. It is supplied in a box of 5 units, the ideal refill format for equipping the electrosurgery cart and keeping the operating theatre stock always available.
2. Technical explanation of the equipment and procedure
In a monopolar electrosurgery system, the electrosurgical generator (ESU) sends high-frequency current through the pencil (electrosurgical unit) to the active electrode, which concentrates the energy at the point of contact with the tissue; the circuit is closed via the neutral (dispersive) plate placed on the patient. Depending on the tip geometry, the predominant effect is cutting, coagulation or mixed.
The sphere (ball) tip of Ø4 mm is designed for contact coagulation, desiccation and controlled fulguration: its rounded shape distributes the current over a larger surface and by contact, achieving effective haemostasis of small vessels and bleeding beds with reduced lateral thermal damage. It is the classic configuration for cauterising delicate surfaces, dermatological surgery, minor bleeding and haemostasis touch-ups at the end of the procedure. The 20º angle of this variant allows the sphere to be oriented towards the exact bleeding point in lateral accesses without forcing the hand position, improving ergonomics and control of the surgical manoeuvre.
The electrode is mounted on a Ø2.38 mm (3/32″) shaft, the industry standard diameter for pencil electrodes, ensuring compatibility with virtually all handpieces, pencils and electrosurgical units with universal housing, without the need for adapters. Its stainless steel construction with insulating anti-shock handle allows sterilisation in an autoclave and reuse for numerous cycles, provided the protocols of the sterilisation department are followed.
3. Technical Specifications
| Characteristic | Specification |
|---|---|
| Reference / SKU | F4045/20 (Cahnos distribution code within the reusable Ø4 mm sphere family) |
| Product type | Reusable monopolar electrosurgery electrode, angled ball tip |
| Tip shape | Sphere (ball / sphere) |
| Ball diameter | Ø4 mm |
| Total length | 156 mm |
| Working angle | 20º (angled tip for lateral accesses) |
| Shaft diameter | 2.38 mm (3/32″) — universal standard |
| Material | Stainless steel (tip) · anti-shock insulation on handle |
| Type of use | Reusable · autoclavable |
| Sterilisation | Autoclave (multiple cycles) |
| Compatibility | Pencils and electrosurgical units with universal 2.38 mm (3/32″) housing |
| Latex | Latex-free |
| Presentation | Box of 5 units (non-sterile) |
The universal 2.38 mm (3/32″) connection allows its use interchangeably with push-button, foot-switch and reusable pencils with standard housing, both those included in the electrosurgery catalogue and most equipment on the market (Valleylab, ConMed, Bovie, Erbe and compatible), without the need for adapters.
Variants of the same reusable sphere tip family (shaft 2.38 mm / 3/32″):
| Reference | Length | Tip | Angle |
|---|---|---|---|
| F4045 | 156 mm | Sphere Ø4 mm | Straight (0°) |
| F4045/10 | 156 mm | Sphere Ø4 mm | 10° |
| F4045/20 (this product) | 156 mm | Sphere Ø4 mm | 20° |
| F4045/30 | 156 mm | Sphere Ø4 mm | 30° |
| F4045/40 | 156 mm | Sphere Ø4 mm | 40° |
| F4068 | 70 mm | Sphere Ø4 mm | Straight (0°) |
| F4064 | 150 mm | Sphere Ø2.5 mm | Straight (0°) |
4. Equivalences and Cross-References
The reference F4045/20 is a Cahnos distribution code within the reusable Ø4 mm sphere family. No equivalence table validated by the manufacturer that cross-references this exact configuration (Ø4 mm sphere + 156 mm + 20º angle + 2.38 mm shaft + reusable) with identical 1:1 codes from other brands has been found in public sources, regulatory databases (GUDID/FDA, EUDAMED) or official catalogues. The following rows are functional comparisons verified against the official catalogue of each cited manufacturer and the GUDID/FDA database, and should be treated as comparable at category level, not interchangeable 1:1 without validation by the technical department.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Bovie / Aspen Surgical (USA) | Reusable angled ball electrode, 3/32″ shaft | A831 | Comparable by category (not interchangeable 1:1) | Reusable ball electrode with standard 3/32″ (2.3 mm) shaft and angled geometry, the closest option in concept to the 20º neck; non-sterile packaging ready for 5–25 autoclave cycles. It matches in category, material and shaft diameter; the sphere diameter and total length differ. Code and attributes verified in Bovie’s official catalogue and authorised distribution. |
| Bovie / Aspen Surgical (USA) | Reusable ball electrode, 3/32″ shaft | A832M | Comparable by category (not interchangeable 1:1) | Reusable monopolar ball-tip electrode with standard 3/32″ (2.3–2.4 mm) shaft, non-sterile packaging ready for autoclave sterilisation (5–25 cycles). It matches in category, material and shaft diameter; the exact sphere diameter, geometry (straight vs 20º) and total length differ. Code and attributes verified in GUDID/FDA (model A832M, Aspen Surgical Products, Inc.; UDI 00840113234585). |
| Bovie / Aspen Surgical (USA) | Reusable 3 mm ball electrode with extended shaft | ES06R | Comparable by category (not interchangeable 1:1) | Reusable monopolar ball electrode with standard 3/32″ (2.36 mm) shaft and extended length for deep fields. It matches in category, material, shaft and spherical tip philosophy; the sphere diameter (Ø3 mm vs Ø4 mm), geometry (straight vs 20º) and presentation differ. Code and attributes verified in GUDID/FDA (model ES06R, Aspen Surgical Products, Inc.; UDI 00840113235018). |
| Gima (Italy) | Autoclavable straight sphere Ø3 mm electrode, Ø2.4 mm shaft | 30510 / 30530 | Comparable by category (not interchangeable 1:1) | Autoclavable stainless steel sphere electrode (up to 20 cycles) with Ø2.4 mm shaft, for monopolar handpieces from the Gima range. It matches in category, material and tip philosophy; the sphere diameter (Ø3 mm vs Ø4 mm), length, straight geometry vs 20º and nominal shaft diameter (2.4 mm vs 2.38 mm) differ. Codes and attributes verified in Gima’s official catalogue. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Before any substitution, check field by field: sphere diameter (Ø4 mm), total length (156 mm), working angle (20º), shaft diameter (2.38 mm / 3/32″), autoclave sterilisation capacity and regulatory classification of the actual product. Other homologous families on the market that should be evaluated with technical data sheet or IFU in hand are the reusable ball electrodes from Medtronic / Valleylab (Covidien), those from the ConMed Hyfrecator range (e.g. 7-222-A) and the autoclavable spherical tips from other European manufacturers with a 2.4 mm shaft.
5. Selection tips and variants of interest
Choose the tip geometry according to the desired effect and surgical access: the Ø4 mm sphere with a 20º angle (F4045/20) is the contact coagulation and haemostasis option with a smooth lateral orientation, ideal for medium-access fields and haemostasis touch-ups at the end of the procedure. If you prefer a straight approach with the same reach, reference F4045 offers the Ø4 mm sphere in 156 mm without an angle; for intermediate angles, F4045/10 (10º) is available and, for greater inclination, F4045/30 (30º) and F4045/40 (40º).
If you need the same coagulation surface in a short format, the same family offers the Ø4 mm sphere in 70 mm (F4068), and the Ø2.5 mm sphere in 150 mm (F4064) provides finer, precision coagulation for delicate surfaces. For cutting and dissection, the reusable 2.38 mm shaft family is completed with blades F4060 (69 mm), F4053R (100 mm), F4062 (curved blade, 150 mm) and F4065 (153 mm), and with needles F4084 (Ø0.75 mm, 69 mm), F4063 (Ø0.78 mm, 152 mm), F4066 (Ø1.30 mm, 152 mm) and F4061 (angled round needle 20º, 100 mm).
Always verify that your pencil accepts a 2.38 mm (3/32″) shaft: virtually all electrosurgical pencils on the market (Valleylab, ConMed, Bovie, Erbe and compatible) accept it, both button and foot pedal types. As a reusable product, follow your centre’s internal cleaning, disinfection and sterilisation protocols, record the number of cycles and remove the electrode at any sign of deterioration of the tip or insulation. As complementary accessories, the sterile tip cleaner F7520 and the sterile sheath F4545 are recommended. For institutional volumes, hospital supply agreements or validation of equivalents from other manufacturers, contact the technical-commercial team at Cahnos.





Reviews