Description
1. Commercial Introduction
The disposable electrosurgery electrode Ref. F4050/TEF is the reference consumable when a long blade with non-stick performance is needed for open surgery and minor surgery procedures. Its 150 mm Teflon (PTFE)-coated blade glides over tissue without dragging carbonised eschar, reduces interruptions to clean the tip and maintains stable performance throughout the procedure. Each box includes 24 sterile single-use units, ready to open at the time of surgery: a safe solution that eliminates the risk of cross-contamination and the costs of re-sterilisation. Available from clinical stock for hospitals, clinics, ambulatory major surgery centres and minor surgery practices.
2. Technical explanation of the equipment and procedure
The F4050/TEF acts as the active electrode of a monopolar electrosurgery system: the radiofrequency current generated by the electrosurgical unit (ESU) travels to the blade tip, where it concentrates on the cutting edge to cut tissue or coagulate small vessels with precise control, returning through the neutral (dispersive) plate placed on the patient. Depending on the selected waveform, the predominant effect will be cutting, coagulation or mixed.
- Teflon (PTFE) coating: non-stick effect that minimises carbonisation and adherence of slough to the tip, reduces surgical smoke and extends electrode performance without frequent cleaning.
- 150 mm blade: long reach for working in deep surgical fields with stability and precision.
- 2.38 mm (3/32″) shaft with hexagonal anti-rotation lock: universal fixation standard, compatible with virtually all pencils and electrosurgical units on the market (Valleylab type and compatible).
- Sterile single-use: sterilised with ethylene oxide (EO), latex-free, ready to use in each procedure.
3. Technical Specifications
| Specification | Detail |
| Reference / SKU | F4050/TEF |
| Product type | Disposable monopolar electrosurgery electrode |
| Length | 150 mm |
| Coating | Non-stick Teflon (PTFE) |
| Tip type | Integrated blade |
| Electrode material | Surgical grade stainless steel |
| Shaft diameter | 2.38 mm (3/32″) — universal standard |
| Fixation system | Hexagonal anti-rotation lock |
| Compatibility | Handpieces with universal 2.38 mm (3/32″) connection, Valleylab type and compatible (Valleylab, ConMed, Bovie, Erbe) |
| Use | Disposable, single-use |
| Sterility | Sterilised with ethylene oxide (EO), individually heat-sealed packaging |
| Latex | Latex-free |
| Presentation | Box of 24 units |
| Shelf life / storage | 4 years from date of manufacture · 0–50 °C · relative humidity 20–80 % |
| Classification | Medical device class IIb · CE marking (Directive 93/42/EEC, notified body 2797) |
Variants of the same family (Teflon coating, 2.38 mm shaft, box of 24 units):
| Reference | Length | Shape |
| F4044/TEF | 70 mm | Sphere Ø 4 mm |
| F4046/TEF | 70 mm | Blade |
| F4048/TEF | 70 mm | Needle |
| F4050/TEF | 150 mm | Blade (this product) |
| F4050S/TEF | 150 mm (sleeve 145 mm) | Blade with insulating sleeve |
| F4052/TEF | 150 mm | Needle |
| F4053/TEF | 100 mm | Blade |
| F4067/TEF | 150 mm | Sphere Ø 4 mm |
| F4050/16TEF | 165 mm | Blade |
4. Equivalences and Cross-References
The reference F4050/TEF belongs to the family of disposable electrodes with Teflon coating and 2.38 mm shaft. No official cross-reference table from the manufacturer validating an exact 1:1 equivalence with other brands has been found in public sources. The following rows are functional comparisons verified against official manufacturer catalogues and the GUDID/FDA regulatory database, and should be treated as comparable at category level, not interchangeable 1:1 without validation from the technical department.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Avicenna Surgical (United Kingdom) | Single Use Blade Electrode, Non-Stick Teflon Coated, 152 mm (6″), hexagonal lock | AVBE010 (pack of 10) | Comparable by category (not interchangeable 1:1) | Same non-stick Teflon (PTFE)-coated blade and same fixation system with hexagonal lock; very similar length (152 mm vs 150 mm). The exact reference and presentation differ (pack of 10 vs box of 24). Code and attributes verified on the manufacturer’s official website. |
| Bovie / Aspen Surgical (USA) | Resistick II™ Coated Extended Blade Electrode, PTFE-coated extended blade, 6″ (15.24 cm) | ES04T (box of 12) | Comparable by category (not interchangeable 1:1) | Disposable sterile extended blade electrode with non-stick PTFE coating and standard 3/32″ (≈2.3–2.38 mm) shaft; very similar length (152.4 mm vs 150 mm). The exact reference, fixation system and presentation differ (box of 12 vs 24). Code and attributes verified in GUDID/FDA (class II, sterile) and in the manufacturer’s catalogue. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Before any substitution, check field by field: blade length (150 mm), coating (Teflon/PTFE), material (stainless steel), shaft diameter (2.38 mm / 3/32″), fixation system (hexagonal lock), sterility and presentation. The third-party codes cited have been verified in public sources and correspond to electrodes of the same category, not certified 1:1 equivalents.
5. Selection tips and variants of interest
The 150 mm blade of the F4050/TEF is indicated when a long electrode is needed for cutting and dissection in open surgery, general surgery, dermatology and minor surgery, with great reach in deep fields. If you need to protect adjacent tissues in delicate areas, the F4050S/TEF reference offers the same blade with a 145 mm insulating sleeve; if even more reach is required, the F4050/16TEF (165 mm) extends the working radius. For more superficial access, the F4053/TEF (100 mm) and F4046/TEF (70 mm) references complete the blade range. The Teflon family is completed with needles (F4048/TEF of 70 mm and F4052/TEF of 150 mm) for precision dissection and pinpoint haemostasis, and with spheres (F4044/TEF of 70 mm and F4067/TEF of 150 mm) for contact coagulation of large surfaces. Always verify that your pencil accepts a 2.38 mm (3/32″) shaft with hexagonal locking: the electrosurgical handpieces from Valleylab, ConMed, Bovie, Erbe and compatible ones accept it. This is a sterile single-use product: do not re-sterilize or reuse. For institutional volumes or tenders, consult our technical-commercial department.