Description
1. Product Presentation
The FIAB F4390/5-75 kit brings together in a single box everything the operating theatre needs for monopolar electrosurgery with hands-free activation: the disposable foot-pedal pencil F4390/5 and the sterile tip cleaner F7520. A complete solution for open surgery that ensures clean cutting, reliable haemostasis and consistent electrode performance throughout the procedure.
Each box contains 50 sterile individual units, ready to open at the time of use. It is the ideal consumption format for hospitals, private clinics, ambulatory surgery centres and purchasing groups seeking the best balance between safety, stock rotation and cost per procedure. Manufactured by FIAB SpA (Vicchio, Florence, Italy), with the reliability of one of Europe’s leading manufacturers of electrosurgery accessories.
2. Technical explanation of the equipment and procedure
The foot-pedal electrosurgery pencil is a monopolar device: the radiofrequency current generated by the electrosurgical unit (ESU) travels through the cable to the active electrode, the F4046 blade, and concentrates at the point of contact with the tissue, producing the desired surgical effect (cut, coagulation or mixed). The circuit is completed through the neutral (dispersive) plate placed on the patient.
Foot-pedal activation frees the surgeon’s hands, allowing cut and coagulation to be controlled with the foot without releasing the instrument or taking the eyes off the operative field, ideal for prolonged manoeuvres and precision dissections. The blade electrode is removable, with a 2.38 mm (3/32″) shaft, the standard diameter compatible with most pencils in the sector and with the F404x range of replacement electrodes. The 500 cm cable provides maximum reach over the operating table, and the 3.2 mm monopolar plug connector fits the standard socket of most generators on the market.
The kit also includes the F7520 tip cleaner: a foam pad with an abrasive surface and adhesive backing that attaches to the drape or Mayo table to remove carbonised eschar from the electrode during the procedure, thus maintaining the effectiveness of cutting and coagulation without unnecessarily raising the generator power. As a sterile single-use product, it eliminates the risk of cross-contamination and the costs of cleaning and re-sterilisation.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F4390/5-75 |
| Packaging | Box of 50 individual units |
| Units per box (web) | 50 |
F4390/5 pencil
| Characteristic | Specification |
|---|---|
| Product type | Disposable electrosurgery pencil (electrosurgical unit), single-use |
| System | Monopolar, cut and coagulation |
| Activation | Foot pedal control (hands-free) |
| Electrode | Removable stainless steel blade (F4046) |
| Shaft diameter | 2.38 mm (3/32″) |
| Cable length | 500 cm |
| Connector | 3.2 mm monopolar plug |
| Sterility | Sterile, single-use disposable |
Tip cleaner F7520
| Characteristic | Specification |
|---|---|
| Product type | Electrode cleaning accessory (tip cleaner) |
| Dimensions | 50 × 50 mm |
| Cleaning surface | Foam with abrasive surface |
| Backing | Adhesive, fixation in the sterile field |
| Radiopacity | Yes (detectable by X-ray) |
| Sterility | Sterile, individual packaging, single-use |
| Latex-free | Yes |
Compatibility: the 3.2 mm connector fits the standard monopolar socket of most electrosurgical generators on the market. For generators with a different connection standard (Valleylab, 4 mm, Erbe), see the variants with a specific connector (e.g. F4390/4M with 4 mm plug) or the reusable adapters from the F4835-F4838 range.
4. Equivalences and Cross-References
There is no equivalence table validated by the manufacturer for this kit reference. The following comparisons come from official catalogues and regulatory databases (GUDID/FDA) and are comparable by category, not interchangeable 1:1 without validation from the technical department.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Aspen Surgical (Bovie) | Electrosurgical Foot Control Pencil (disposable foot pedal control pencil with blade electrode, box of 50 units) | ESP7 | Comparable by category (not interchangeable 1:1) | Disposable foot-pedal pencil, monopolar, sterile, single-use, with blade electrode and box of 50 units. Differs: 1-pin connector versus 3.2 mm plug, cable length and kit without F7520 cleaner. |
| Medline Industries | Pencil, Cautery, Foot Switch, PTFE Blade | ESFS3002 | Comparable by category (not interchangeable 1:1) | Disposable cautery pencil with foot-pedal activation and mounted electrode, 50 units. Differs: blade electrode with PTFE coating, cable length and connector standard. |
| Key Surgical / STERIS | Cautery Tip Cleaner (tip cleaner, 50×50 mm, box of 100) | TC200 | Comparable by category (not interchangeable 1:1) | Reference for the F7520 accessory included in the kit: abrasive foam, adhesive backing, radiopaque and sterile. |
| Medtronic / Covidien (Valleylab) | Valleylab Electrosurgical Tip Cleaner (LectroBrasive) | E2401 | Comparable by category (not interchangeable 1:1) | Sterile pad of 2 × 2 inches (approx. 50 × 50 mm) with adhesive backing, radiopaque and single-use, for the F7520 accessory. |
Before any replacement, verify field by field: electrode type, shaft diameter (2.38 mm / 3/32″), cable length, installed generator connector, sterility and presentation.
5. Selection tips and variants of interest
Check your generator connector: this kit is fitted with a 3.2 mm monopolar connector. If your ESU is of a different standard (Valleylab, 4 mm, Erbe), choose the variant with specific connector F4390/4M (4 mm plug) or use the reusable adapters from the F4835-F4838 range.
F4390 foot-pedal family (2.38 mm shaft): F4390 (F4046 blade, 320 cm cable), F4390/5 (F4046 blade, 500 cm cable), F4390/A (F4048 needle), F4390/P (F4044 ball), F4390/L (F4050 blade), F4390/AL (F4052 needle), F4390/PL (F4067 ball) and F4390/4M (F4046 blade, 4 mm connector).
Kits and accessories: this F4390/5-75 kit includes the F7520 tip cleaner; the F4390/75 variant offers the same pencil with 320 cm cable and F7520 cleaner. The sterile sheath F4545 (kits F4390/H and F4390/5H) allows the pencil to be fixed to the surgical field and completes the operating theatre equipment.
Single-use product: do not re-sterilise or reuse. For institutional volumes or tenders, please contact our technical-commercial department.