Description
1. Product Presentation
The disposable rocker-type electrosurgical unit Ref. F4795 is the consumable your operating theatre team needs for open surgery: clean cutting, reliable haemostasis and the peace of mind of a sterile single-use product, ready to use in every procedure. Its rocker switch allows you to alternate between cutting and coagulation without letting go of the instrument, and its universal Valleylab-type connector guarantees compatibility with the most widespread electrosurgical generators (ESU) on the market.
Supplied in a box of 50 sterile units with reference F4795, it is the ideal option for hospitals, private clinics and purchasing centres seeking the best balance between cost per procedure, safety, constant supply and performance in every procedure.
2. Technical explanation of the equipment and procedure
The rocker-type electrosurgical unit is a monopolar electrosurgery pencil: the radiofrequency current generated by the generator (ESU) travels through the cable to the active electrode (the F4046 blade) and concentrates at the point of contact with the tissue, producing the desired surgical effect —cutting, coagulation or mixed— and returning through the patient’s neutral (dispersive) plate.
- Rocker activation: front press for cutting and rear press for coagulation, with automatic return and tactile and audible feedback that prevents accidental activation.
- Stainless steel blade F4046: stable edge for repeated dissection and coagulation, compatible with the F404x replaceable electrode family (3/32″ shaft).
- 2.38 mm shaft: standard diameter in pencil electrodes, compatible with the housing of most pencils in the sector.
- 320 cm cable: wide reach over the surgical field without tension, designed to distribute across the table and move the pencil freely.
- Valleylab-type connector: universal 3-pin connection compatible with generators from the Valleylab/Covidien family and with a large part of the multipin ESUs on the market.
Being a sterile single-use device, it eliminates the risk of cross-contamination and the costs of cleaning and re-sterilisation.
3. Technical Specifications
| Characteristic | Specification |
| Product type | Disposable electrosurgery pencil (electrosurgical unit), single-use |
| System | Monopolar, cut and coagulation |
| Activation | Rocker-type toggle switch (on the handle) |
| Electrode | Stainless steel blade F4046 |
| Shaft diameter | 2.38 mm (3/32″) |
| Cable length | 320 cm |
| Connector | Universal Valleylab type (3 pins) |
| Sterility | Sterile, single-use disposable |
| Presentation | Box of 50 units |
| Reference | F4795 |
Compatibility: the 3-pin Valleylab-type connector fits the standard socket of most electrosurgical generators on the market (Medtronic/Covidien and compatible). For generators with another connection standard (Erbe, 4 mm, 3.2 mm), consult the variants with a specific connector or the reusable adapters in the range.
4. Equivalences and Cross-References
Reference F4795 is a distribution code proprietary to Cahnos. There is no equivalence table validated by the manufacturer covering this reference; the following rows are functional comparisons verified against official catalogues and regulatory databases (GUDID), not 1:1 equivalences.
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
| Medtronic (Covidien) — Valleylab | Valleylab Electrosurgical Rocker Switch Pencil | E2515 | Comparable by category (not interchangeable 1:1) | Same type of product (disposable pencil with rocker activation, 3-pin connector and box of 50 units) and same shaft geometry (3/32″ = 2.4 mm). Differs: stainless steel electrode with hex-locking fixation versus the F4046 blade and 10 ft (≈3 m) cable. Confirmed on the official Medtronic website, authorised distribution catalogue and GUDID (model E2515, Covidien LP). |
| Bovie (Aspen Surgical) | Bovie Disposable Rocker Switch Pencil | ESP6 | Comparable by category (not interchangeable 1:1) | Sterile disposable pencil with rocker activation, standard 3-pin connector compatible with Valleylab-type generators, box of 50 units and 3/32″ (2.36 mm) shaft. Differs: included stainless steel blade without the F4046 designation. Confirmed in the official Aspen Surgical catalogue and authorised distribution. |
There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. For a 1:1 replacement, always verify the electrode (type, material and fixation system), the shaft diameter (2.38 mm), the cable length, the connector type of the installed generator and the presentation.
5. Selection tips and variants of interest
- Check your generator’s connector: this pencil mounts a universal Valleylab-type connector; if your ESU is of another standard (Erbe, 3.2 mm, 4 mm), consult the variants with a specific connector or the reusable adapters in the range (F4830–F4834).
- Choose the cable length according to your operating theatre: the 320 cm model is the standard for general surgery tables; if you need more reach, the family is completed with the 500 cm variant (F4795/5).
- Standard steel vs. TEF coating: the stainless steel F4046 blade covers the standard clinical function with the best cost per unit; if you need minimal tissue adherence in long dissections and repeated coagulations, there is the variant with F4046/TEF blade with Teflon coating (F4795/TEF).
- Variants within the family: F4795 (rocker, F4046 blade, 320 cm), F4795/5 (rocker, F4046 blade, 500 cm), F4795/TEF (rocker, F4046/TEF blade, 320 cm), F4797/F4798 (button switch, F4046 blade) and F4390 (foot pedal control) allow the pencil to be adapted to the surgeon’s preference and to the equipment of each centre.
- Recommended accessories: sterile sheath F4545 (holster) and sterile tip cleaner F7520 to maintain electrode performance during the procedure.
Single-use product: do not re-sterilise or reuse.