Description
1. Commercial Introduction
The flexible rubber electrosurgical plate (reference 30565) is the reusable return electrode that your monopolar electrosurgical unit needs to work with complete safety. With dimensions of 25 x 15 cm and an integrated 4.5 m cable, it offers a ready-to-use solution: it connects directly to the generator without the need for additional cables and can be reused between patients after proper cleaning and sterilisation. Its flexible, ergonomic design makes it the usual choice for operating theatres, ambulatory surgery centres and veterinary clinics seeking to reduce the cost per procedure and medical waste compared with disposable plates.
2. Technical Explanation
In any procedure involving a monopolar electrosurgical unit, the high-frequency current that leaves via the active electrode (handpiece or pencil) must return to the generator through a low current density path. The neutral plate collects this return current in a controlled manner: if the skin-plate contact is not correct or the surface area is insufficient, the current density at the return point increases and with it the risk of thermal burn to the patient. This flexible conductive rubber plate ensures a broad, uniform contact surface, adapting to the body contour and reducing the likelihood of energy concentrations. Being autoclavable, it can be sterilised after each use following the manufacturer’s indications, making it especially suitable for environments where material reuse is prioritised. It is recommended to always apply it on dry, intact, hair-free skin, over a well-vascularised muscle area away from the surgical site, verifying correct contact before activating the equipment.
3. Technical Specifications
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 30565 |
| Product type | Reusable flexible rubber electrosurgical plate (return electrode) |
| Measurements | 25 x 15 cm |
| Cable | Integrated, 4.5 m |
| Sterilisation | Autoclavable |
| Sales unit | 1 pc |
| Device type | Medical device (medical device) |
| Device class | II B |
| CND | Z12010980 |
| EAN | 8023279305654 |
4. Equivalences and Cross-References
No official equivalence table validated by the manufacturer and cross-referencing reference 30565 with identical codes from other brands has been found in reliable sources; any substitution must be validated field by field with the technical department at Cahnos before use. Within the reusable return electrode range itself, the following references are listed as complementary or comparable by function:
| Reference | Product | Related items |
|---|---|---|
| 30556 / 30555 | Flexible steel-rubber plate 120 x 210 mm, autoclavable (with cable ref. 30560) | Comparable by function / smaller format variant |
| 30574 | Two-part rubber REM plate 20 x 15 cm without cable (requires cable 30575) | Comparable by function, with REM system and without cable |
| 30566 | Reusable metal neutral plate without cable (requires cable 30560) | Non-flexible reusable alternative |
| 30560 / 30575 | Connection cables for reusable plates | Complementary accessories |
5. Selection tips and variants of interest
Check compatibility with your electrosurgical unit: this plate with integrated 4.5 m cable is designed for the diathermy units in the electrosurgical range, so it is advisable to verify the connector on your generator before purchase. If you prefer a plate with a smaller surface area or with a REM contact monitoring system, consider ref. 30574 (20 x 15 cm, two-part); for greater return rigidity, the metal plate ref. 30566 or the flexible steel-rubber plate refs. 30555/30556 are alternatives from the same reusable family. Maintenance: after each use, clean the conductive surface according to the manufacturer’s indications, sterilise it in an autoclave and inspect it visually before each procedure, replacing it if there are any cracks, cuts or loss of conductivity. For volume orders or B2B hospital supply conditions, contact the technical-commercial team at Cahnos.