Description
1. Product Presentation
The disposable electrosurgery electrode Ref. F4048T is the reference consumable when high-precision cutting and coagulation are required with a short, manageable reach. Its 70 mm titanium-coated needle tip combines maximum energy concentration with a clean glide over tissue: less carbonised eschar, fewer interruptions to clean the tip and consistent performance throughout the procedure.
Each box includes 24 sterile single-use units, ready to open at the time of surgery; a safe solution that eliminates the risk of cross-contamination and resterilisation costs. Clinical stock available immediately for hospitals, clinics, ambulatory surgery centres and minor surgery practices.
2. Technical explanation and operation
The F4048T is the active electrode of a monopolar electrosurgery system: the radiofrequency current generated by the electrosurgical unit (ESU) travels to the needle tip and concentrates at a minimum contact point, producing the desired surgical effect —cut, coagulation or mixed— and returning through the patient’s neutral (dispersive) plate.
- Needle tip Ø 0.75 mm: maximum energy concentration for fine incisions, precision dissection and targeted haemostasis, ideal in dermatological surgery, minor surgery and open surgery on superficial fields.
- Titanium coating: non-stick effect that reduces carbonisation and adherence of slough, maintains conductivity and extends tip performance without frequent cleaning.
- 70 mm length: contained reach, with great control and stability, perfect for outpatient procedures and areas with restricted access.
- 2.38 mm (3/32″) shaft with anti-rotation hexagonal lock: universal fixation standard, compatible with virtually all pencils and electrosurgical units on the market (Valleylab, ConMed, Bovie, Erbe and compatible types).
- Sterile single-use: sterilised with ethylene oxide (EO), latex-free, ready to use in each procedure.
3. Technical Specifications
Disposable electrosurgery electrode manufactured from medical-grade stainless steel with titanium coating and integrated needle, ensuring optimal and consistent performance in every use.
| Specification | Detail |
|---|---|
| Reference / SKU | F4048T · 0565023 |
| Product type | Disposable monopolar electrosurgery electrode, needle tip |
| Total length | 70 mm |
| Coating | Titanium (non-stick effect), corrosion-resistant |
| Tip type | Precision needle, Ø 0.75 mm |
| Electrode material | Medical-grade stainless steel (AISI) with titanium coating |
| Shaft diameter | 2.38 mm (3/32″) |
| Fixation system | Hexagonal anti-rotation lock |
| Compatibility | Handpieces with universal connection 2.38 mm (3/32″), Valleylab type and compatible |
| Use | Disposable, single-use |
| Sterility | Sterilised with ethylene oxide (EO), individually heat-sealed packaging |
| Latex | Latex-free |
| Presentation | Box of 24 units |
| Classification | Medical device Class IIb · CE marking (Directive 93/42/EEC and amendments, notified body 2797) |
| Expiry | 4 years from the date of manufacture |
| Storage | 0–50 °C · relative humidity 20–80 % |
Variants of the same family (titanium coating, 2.38 mm (3/32″) shaft, box of 24 units):
| Reference | Length | Tip shape |
|---|---|---|
| F4044T | 70 mm | Sphere Ø 4 mm |
| F4046T | 70 mm | Blade |
| F4048T | 70 mm | Needle (this product) |
| F4050T | 153 mm | Blade |
| F4052T | 152 mm | Needle |
| F4067T | 156 mm | Sphere Ø 4 mm |
Compatibility note: verify that your pencil accepts a 2.38 mm (3/32″) shaft with hexagonal lock; virtually all electrosurgical units on the market (Valleylab, ConMed, Bovie, Erbe and compatible types) accept it.
4. Equivalences and Cross-References
Reference F4048T is an own distribution code; no official manufacturer cross-reference table has been found in public sources validating an exact 1:1 equivalence with other brands. The following rows are functional comparisons verified against official catalogues and the GUDID/FDA regulatory database, and should be treated as comparable at category level, not interchangeable 1:1 without validation by the technical department.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Bovie / Aspen Surgical (USA) | Bovie® Needle Electrode (standard stainless steel needle, single-use, sterile) | ES02 (needle 2 3/4″ / 7 cm ≈ 70 mm, shaft 3/32″, box of 25) | Comparable by category (not interchangeable 1:1) | Sterile disposable needle electrode with universal 3/32″ (2.3–2.38 mm) shaft and handle with grip insulation (safety grip); practically identical length (7 cm vs. 7 cm). Differences: no titanium coating, integrated handle and presentation (25 units vs. 24). Code and attributes verified on the official Aspen Surgical website and in GUDID/FDA. |
| Medtronic / Valleylab | Valleylab™ Stainless Steel Needle Electrode (standard stainless steel needle, single-use) | E1552 (needle 2.8″ / 7.2 cm ≈ 72 mm, shaft 3/32″, box of 150) | Comparable by category (not interchangeable 1:1) | Single-use monopolar needle electrode in stainless steel with standard 3/32″ (2.38 mm) shaft and hub fixation; very similar total length (7.2 cm vs. 7 cm). Differences: no titanium coating, exact length and presentation (box of 150 vs. 24). Code and attributes verified in GUDID/FDA (Covidien LP, Valleylab brand). |
| ConMed (USA) | Needle Electrode with Extended Insulation (needle with extended insulation, hexagonal hub) | 138105 (box of 40) | Comparable by category (not interchangeable 1:1) | Single-use, sterile stainless steel needle electrode with hexagonal hub and 3/32″ (2.38 mm) shaft; incorporates extended shaft insulation. Differences: length, insulation, no titanium coating and presentation (40 units vs. 24). Code and attributes verified in GUDID/FDA (ConMed Corporation). |
There is no manufacturer-validated equivalence table; consult the technical department before use in tenders. Before any substitution, check field by field: total length (70 mm), needle diameter (0.75 mm), shaft diameter (2.38 mm / 3/32″), fixation system (hexagonal lock), coating (titanium), sterility and presentation. Homologous families in the sector with functionally equivalent non-stick behaviour (PTFE coating instead of titanium) include the NonStick lines from Prima Medical and Resistick II from Aspen Surgical / Bovie, as well as the needle electrodes from Medtronic (Valleylab) and ConMed; always verify material, coating and dimensions in the manufacturer’s datasheet before substituting. The third-party codes cited have been verified in public sources and correspond to electrodes in the same category, not certified 1:1 equivalents.
5. Selection tips and variants of interest
The F4048T needle tip is indicated for precision dissection, fine incisions and targeted haemostasis in superficial-field procedures: dermatological surgery, minor surgery, biopsies and open surgery with restricted access, with great control thanks to its 70 mm length. In applications where cost per procedure is prioritised, reference F4048 offers the same 70 mm needle geometry in uncoated stainless steel; if an alternative non-stick effect is preferred, the F4048/TEF (70 mm needle with Teflon/PTFE coating) is the option from the same family, and the F4048/S adds an insulating sleeve to protect adjacent tissues.
For greater reach in deep fields with titanium coating, the F4052T offers the same needle in 152 mm; the titanium range is completed with the blades F4046T (70 mm) and F4050T (153 mm) and with the spheres F4044T (70 mm) and F4067T (156 mm) for surface coagulation. Always verify that your pencil accepts a 2.38 mm (3/32″) shaft with hexagonal locking: Valleylab, ConMed, Bovie, Erbe and compatible electrosurgical units accept it. This is a single-use product: do not re-sterilise or reuse. For institutional volumes or tenders, consult our technical-commercial department.