We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Reusable electrosurgical silicone plate 200 x 150 mm (250 cm²) with REM system and 4 mm socket connection — cable-free return electrode for electrosurgical unit (Price per unit) Ref. F7930

32,68 €

Reusable electrosurgical plate (return electrode) of conductive silicone, 200 x 150 mm and 250 cm² of surface area, with REM system for contact monitoring and 4 mm female socket connection. Designed without cable: it connects to the electrosurgical unit via reusable plate cable (refs. F7923 Valleylab type with REM, F7922/24 or F7922/4), and is therefore compatible with electrosurgical generators with REM-type return electrode monitoring. Ideal for operating theatres, consulting rooms and veterinary clinics looking for a durable and washable alternative to disposable plates. Sold per unit. Ref. F7930.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
F7930

Description

Reusable silicone electrosurgical plate with REM — Ref. F7930

We present the reusable silicone electrosurgical plate with REM system, a solution designed for professionals who need a reliable, durable and reusable return electrode for their monopolar electrosurgery. Its compact design of 200 x 150 mm with 250 cm² of surface area offers an excellent balance between contact safety, patient comfort and cost per use compared with disposable plates, with the advantage of being able to be cleaned and reused in multiple procedures.

It is the usual choice in operating theatres, minor surgery clinics, dermatology, dentistry and veterinary clinics that work with high-frequency electrosurgical equipment and wish to reduce medical waste and the recurring cost of single-use electrodes.

Technical explanation

In monopolar electrosurgery, the high-frequency current flows from the active electrode (pencil) through the patient to a return plate (neutral electrode) that closes the circuit. If the contact of that plate with the skin is not correct, current density concentrates on a reduced surface and a burn may occur on the patient.

The REM system (Return Electrode Monitoring) is the return electrode monitoring technology associated with Valleylab-type generators and other equipment with split-plate control: the generator continuously monitors contact impedance and blocks emission with an alarm if it detects poor contact. This plate, designed to work with the REM system, has a 4 mm female socket: it is supplied without cable, so it is connected to the electrosurgical unit via the reusable plate cable most suitable for each device (see table of compatible cables). Universal bipolar cables with double 4 mm plug (ref. F7922/24) or Valleylab type with REM (ref. F7923) allow its use with numerous electrosurgical units, including Valleylab, Bowa, Conmed and Erbe equipment (depending on connector configuration).

As it is reusable, it must be cleaned after each use, visually inspected (no cuts, cracks or deterioration of the conductive surface) and continuity checked periodically before each procedure; it must be replaced at any sign of degradation.

Technical specifications

Characteristic Specification
Reference (SKU) F7930
Product type Reusable silicone electrosurgical plate (return electrode)
Material Medical-grade conductive silicone, latex-free
Dimensions 200 x 150 mm
Surface (area) 250 cm²
Monitoring system REM (Return Electrode Monitoring), for generators with return electrode control
Cable Without cable (cable-free design; requires connection cable, not included)
Connection 4 mm female socket
Type of use Reusable (multiple uses)
Presentation Price per unit
Compliance Medical device; confirm CE marking and classification in the manufacturer’s original data sheet (EU Regulation 2017/745)

Connection cables for reusable plates compatible with the 4 mm socket of this plate (Cahnos catalogue):

Reference Description
F7922 Universal cable, 6.3 mm mono jack connector, 500 cm
F7922/4 Cable with 4 mm plug, 500 cm
F7922/24 Cable with double 4 mm plug, 500 cm
F7923 Valleylab type cable (ESU with REM), 500 cm
F7923/F Valleylab type cable (ESU without REM), 500 cm
F7924 Special 6.3 mm mono jack cable for Erbe (ACC, ICC, VIO), 500 cm

Equivalences and cross-references

This category of reusable silicone return electrodes is marketed internationally under the generic name of reusable silicone neutral plates with REM connector. Among the homologous families at category level are the reusable silicone plates from the surgical electrode range of manufacturers such as Megadyne (capacitive range Mega Soft / Mega 2000, based on capacitive coupling principle and flexible surface not 1:1 interchangeable with a conductive silicone plate), the reusable silicone plates from Bovie/Apyx and the reusable silicone electrodes with REM connector from Asian manufacturers such as YKD Medical (reusable plate model TS111, pending verification of dimensions and configuration against official source), as well as reference BMH-EDC0001A (reusable silicone return plate with distal REM connector, seen at an authorised distributor: 300 x 180 mm and integrated 3 m cable, pending confirmation and not 1:1 interchangeable due to differences in dimensions, surface and absence of 4 mm socket). In all cases, before replacement, verification must be carried out field by field: material, dimensions, active surface, connector compatibility and generator monitoring system.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.

Selection tips and variants of interest

  • Non-REM version: if your electrosurgical unit does not have return electrode monitoring, consider the reusable silicone plate of 200 x 150 mm (266 cm²) without REM system, with the same 4 mm socket (ref. F7915), from the same technical family.
  • Cable selection: for equipment with REM system preferably use the Valleylab-type cable with REM (F7923) or the double 4 mm cable (F7922/24); for equipment without REM, use cable F7923/F or F7922/4. Always confirm the connector type of your generator before choosing the cable.
  • Generator compatibility: verify that your electrosurgical unit accepts reusable plates with a 4 mm connection and REM system (Valleylab, Bowa, Conmed, Erbe types in international configurations with the appropriate cable).
  • Maintenance: clean the plate after each use with the products recommended by the manufacturer, dry it completely and store it without folds; check the conductive surface before each procedure and replace the plate if it shows cracks, cuts or loss of conductivity.
  • Placement: apply the plate to healthy, dry and well-shaved skin, as far as possible from the surgical site and avoiding areas with hair, scars or bony prominences to ensure uniform contact.
  • Institutional purchases: for operating theatre equipment, veterinary clinics or volume orders with special B2B conditions, contact our technical-commercial department.

Additional information

Reference

F7930

Product type

Reusable silicone electrosurgical plate (return electrode)

Material

Medical-grade conductive silicone, latex-free

Dimensions

200 x 150 mm

Active surface

250 cm²

REM system

Yes (compatible with generators with REM-type return electrode monitoring)

Cable

Without cable (cable-free design)

Connection

4 mm female socket

Usage type

Reusable (multiple uses)

Cable compatibility

F7922, F7922/4, F7922/24, F7923 (Valleylab type with REM), F7923/F, F7924 (Erbe)

Regulatory standard

Medical device; confirm CE marking and classification in the manufacturer's original data sheet (EU Regulation 2017/745)

Presentacion

Unit

Latex

Latex-free

Reviews

There are no reviews yet.

Be the first to review “Reusable electrosurgical silicone plate 200 x 150 mm (250 cm²) with REM system and 4 mm socket connection — cable-free return electrode for electrosurgical unit (Price per unit) Ref. F7930”

Your email address will not be published. Required fields are marked *