Paediatric disposable foam electrosurgical plate, 148 x 90 mm (72 cm²), with REM system, 300 cm cable and Valleylab-type connection — box of 25 units (Ref. F7820PW/V)

50,31 €

Paediatric foam electrosurgical plate with REM system (Return Electrode Monitoring), dimensions 148 x 90 mm and active surface area of 72 cm². Includes 300 cm cable with Valleylab-type connection, directly usable with electrosurgery generators with REM contact monitoring. Conductive hydrogel on a polyethylene foam backing that ensures anatomical adaptation and uniform current distribution. Presentation in a box of 25 units with individual packaging: single-use, latex-free and non-sterile product. Reference F7820PW/V.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
F7820PW/V

Description

Paediatric foam electrosurgical plate with REM and Valleylab connection

The paediatric foam electrosurgical plate is the essential return electrode for completing the monopolar circuit of any high-frequency electrosurgery unit when operating on paediatric patients. This reference, with dimensions 148 x 90 mm and 72 cm² of active surface area, incorporates a REM system and a 300 cm cable with Valleylab-type connection, making it directly usable with generators that use this connection standard.

It is supplied in a box of 25 units with individual packaging, a choice favoured by hospitals, clinics and ambulatory surgery centres that require reliable, consistent consumption with permanent stock for their surgical scheduling. Each package protects the conductive hydrogel until the moment of use.

How the REM return plate works and why it is important

In any monopolar electrosurgical procedure, the high-frequency current must return to the generator through a low current-density pathway. The neutral plate is responsible for collecting that current in a controlled manner: if the contact is not correct or the surface is insufficient, the current density at the return point increases and, with it, the risk of thermal burn to the patient.

This plate is constructed with a polyethylene foam backing and conductive hydrogel adhesive, which favours adaptation to the body contour of the paediatric patient and uniform contact with the skin. Its active surface is divided into two sections, allowing operation with generators equipped with a REM system (Return Electrode Monitoring): the unit continuously measures contact impedance and, if it detects a loss of contact quality or a fault, it interrupts energy emission before injury occurs.

The Valleylab-type connection with a 300 cm cable offers direct compatibility with the standard connectors of REM equipment in the Valleylab range and with other generators that accept this type of plug, ensuring freedom of placement of the plate on the patient during the procedure.

Technical specifications

Data verified according to the manufacturer’s technical data sheet for the family of paediatric foam plates:

Characteristic Value
Reference / SKU F7820PW/V
Product type Disposable return plate (electrode) for monopolar electrosurgery
Population Paediatric
Measurements 148 x 90 mm
Active surface 72 cm²
Support Polyethylene foam
Adhesive Conductive hydrogel
Safety system REM (Return Electrode Monitoring), plate divided into two sections
Cable length 300 cm
Connection Valleylab type (REM)
Use Single-use (disposable, non-sterile)
Presentation Box of 25 units with individual packaging
Latex-free Yes
Regulatory classification CE-marked medical device, class IIb

Paediatric range of the foam family (148 x 90 mm): all references share the same foam backing and hydrogel adhesive; the difference lies in the REM system and the connection method to the generator.

Reference Measurements Active surface REM Cable Connection
F7805P 148 x 90 mm 78 cm² No No TAB (tabs)
F7805PW/V 148 x 90 mm 78 cm² No 300 cm Valleylab
F7820P 148 x 90 mm 72 cm² Yes No TAB (tabs)
F7820PW/V 148 x 90 mm 72 cm² Yes 300 cm Valleylab

Equivalences and cross-references

There is no official equivalence table validated by the manufacturer that cross-references this reference with codes from other brands. The comparisons shown below are functional comparisons verified against documentation from each cited manufacturer and should not be treated as 1:1 interchangeable without validation from the technical department.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Medtronic / Covidien (Valleylab) Valleylab™ REM PolyHesive™ II Return Electrode paediatric/infant with cable E7510-25 (box of 25) Comparable by category (not interchangeable 1:1) Same REM return function with Valleylab-type connector, single-use paediatric/infant use and integrated cable. They differ in the substrate (PolyHesive™ II hydrogel versus foam backing), exact dimensions and cable length (2.7 m / 9 ft versus 300 cm). Code verified in GUDID/FDA (UDI 10884524001043) and on Medtronic’s official website.
Nissha Medical Technologies (Graphic Controls) SWAROPLATE Split Diathermy Pad Pediatric REM 1253H-SWARO-V1-8-96 (6000834N) Comparable by category (not interchangeable 1:1) Very similar option: paediatric split plate with REM control, polyethylene foam backing (PE foam), conductive hydrogel adhesive and Valleylab-REM connector with 3 m cable. Differences: dimensions (165 x 74 mm versus 148 x 90 mm) and active surface area (66 cm² versus 72 cm²). Code and attributes verified in the manufacturer’s official catalogue.
Leonhard Lang (Skintact® Cool Contact) Skintact® Split Neutral Electrode Pediatric, with 3 m cable and REM connector RS26A30 (Electrode Size 13 x 11 cm, Conductive Area 66 cm², cable 3 m, connector REM) Comparable by category (not interchangeable 1:1) Paediatric split plate with contact quality control, foam backing and hydrogel adhesive, 3 m cable and REM connector (Valleylab). Differences: conductive area (66 cm² versus 72 cm²) and electrode dimensions (13 x 11 cm). Code and attributes verified in the official technical data sheet (datasheet RS26A30, Leonhard Lang GmbH).

The cited references have been cross-checked against regulatory databases (GUDID/FDA) and the official catalogues of each cited manufacturer. Although they match in function (return electrode with REM control, Valleylab-type connector, paediatric population, single-use), they differ in substrate, exact dimensions and, in some cases, cable length, and are therefore not interchangeable 1:1. There is no equivalence table validated by the manufacturer; consult the technical department before using in a tender.

Other homologous families in the sector that should be assessed with the technical data sheet in hand before any substitution: the range of divided paediatric neutral plates from B.Braun / Aesculap, disposable bipartite REM plates from GIMA, and neutral electrode manufacturers present on technical portals such as EMED, Promed, Richmedi or Upspring Medical. It is recommended to check field by field: exact dimensions, active surface area in cm², backing and hydrogel type, REM system, physical connector and compatibility with the installed generator.

Selection tips and variants of interest

  • Check your generator connector: this reference F7820PW/V is for equipment with a Valleylab-type return socket with REM control. If your equipment uses a bipolar jack of Ø6.3 mm (Erbe-type standard), consider the adult reference F7820W/6.3 or consult the technical department for the appropriate paediatric variant.
  • If your generator does not have REM control, the equivalent option in the same size with a 300 cm cable and Valleylab connection is reference F7805PW/V (148 x 90 mm, 78 cm², without REM).
  • Cable-free version with tab connection (TAB) for the same paediatric population: F7820P (148 x 90 mm, 72 cm², with REM), indicated when the generator has its own connection cable or when working with plate cables such as F7903.
  • For other populations: adult F7820W/V (202 x 101 mm, 118 cm², REM, 300 cm, Valleylab) and neonatal F7820NW/V (88 x 74 mm, 36 cm², REM, 300 cm, Valleylab).
  • To extend compatibility with other generators, the adapters F4828 (from Valleylab-type connection to 4 mm plug) and F4829 (to 6.3 mm plug) can be used, as well as the connection cable F7903 (Valleylab type with REM).
  • Always apply to dry, intact, hair-free skin, on a well-perfused muscle area and away from prominent bony areas. Check the integrity of the individual packaging and the expiry date before use: it is a single-use, non-sterile product.

Additional information

Reference

F7820PW/V

Product type

Disposable return plate (electrode) for monopolar electrosurgery

Measurements

148 x 90 mm

Active surface

72 cm²

Support

Polyethylene foam

Adhesive

Conductive hydrogel

Safety system

REM (Return Electrode Monitoring), plate divided into two sections

Cable length

300 cm

Connection

Valleylab type (REM)

Use

Single-use (disposable, non-sterile)

Presentation

Box of 25 units with individual packaging

Regulatory classification

CE-marked medical device, Class IIb (family F7820)

Material

Polyethylene foam backing (PE foam) with conductive hydrogel adhesive

Compatibility

Electrosurgical generators with Valleylab-type return connection and REM control

Tipo paciente

Paediatric