Description
Electrosurgical foam plate with REM and Valleylab-type connection
The electrosurgical foam plate is the essential return electrode for completing the monopolar circuit of any high-frequency electrosurgery equipment. This adult reference, measuring 202 x 101 mm with 118 cm² of active surface, incorporates REM system (Return Electrode Monitoring) and a 300 cm cable with Valleylab-type connection, making it directly usable with generators that use this plug standard.
It is supplied in a box of 25 units and is the option chosen by hospitals, clinics and ambulatory surgery centres that need reliable, consistent consumption with permanent stock for their surgical scheduling. Each unit comes in an individual heat-sealed aluminium-polyethylene package that protects the hydrogel until the moment of use.
How the return plate works and why it is important
In any procedure with a monopolar electrosurgical unit, the high-frequency current must return to the generator through a low current-density path. The neutral plate collects this current in a controlled manner: if contact is not correct or the surface is insufficient, the current density at the return point increases and, with it, the risk of thermal burn.
This plate is constructed with a polyethylene foam (PE foam) backing and conductive hydrogel adhesive, which favours adaptation to the patient’s contour and uniform contact with the skin. Its active surface is divided into two sectors, allowing operation with generators equipped with a REM system: the equipment continuously measures contact impedance and, if it detects a loss of contact quality or a fault, it interrupts energy delivery before injury occurs. The Valleylab-type connection with a 300 cm cable guarantees direct compatibility with REM generators in the Valleylab range and with other equipment that accepts this plug, offering freedom of plate placement on the patient during the procedure.
Technical specifications
| Characteristic | Value |
|---|---|
| Reference / SKU | F7820W/V |
| Product type | Disposable return plate (electrode) for monopolar electrosurgery |
| Measurements | 202 x 101 mm |
| Active surface | 118 cm² |
| Support | Polyethylene foam |
| Adhesive | Conductive hydrogel |
| Safety system | REM (Return Electrode Monitoring), split plate |
| Cable length | 300 cm |
| Connection | Valleylab type (REM) |
| Population | Adult (patient weight ≥ 15 kg) |
| Use | Single-use (disposable, non-sterile) |
| Presentation | Box of 25 units with individual heat-sealed packaging |
| Impedance | < 14.0 Ω @ 200 kHz |
| Max. operating temperature | < 3.5 °C @ 700 mA |
| Latex-free | Yes |
| Expiry | 36 months from date of manufacture |
| Storage | +5 °C to +35 °C; relative humidity 20–80 % |
| Regulatory standard | Directive 93/42/EEC; EN 60601-2-2; EN ISO 10993-1 |
| Regulatory classification | CE medical device, Class IIb |
Adult range of the foam family with REM
| Reference | Dimensions | Support | Active surface | REM | Cable | Connection |
|---|---|---|---|---|---|---|
| F7820 | 202 x 101 mm | Foam | 118 cm² | Yes | No | Tabs (TAB) |
| F7820W/V | 202 x 101 mm | Foam | 118 cm² | Yes | 300 cm | Valleylab type |
| F7820W/6.3 | 202 x 101 mm | Foam | 118 cm² | Yes | 300 cm | Bipolar Ø 6.3 mm |
The three references share the same hydrogel and foam base, the same active surface of 118 cm² and the same REM system; the difference lies exclusively in the connection system to the generator.
Equivalences and cross-references
There is no official equivalence table validated by the manufacturer that cross-references this reference with codes from other brands. The comparisons shown below are verified functional comparisons against documentation from each cited manufacturer and should not be treated as 1:1 interchangeable without validation by the technical department.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Medtronic / Covidien (Valleylab) | REM PolyHesive™ Adult Patient Return Electrode (with cable) | E7507 (UDI 10884524000077) | Comparable by category (not interchangeable 1:1) | Same REM return function with Valleylab-type connector, adult use and single-use, indicated for patients > 13.6 kg (30 lb). The substrate differs (PolyHesive™ II hydrogel adhesive versus polyethylene foam backing), as do the exact measurements and cable length (2.7 m / 9 ft versus 300 cm). Code and attributes verified in GUDID/FDA and on the manufacturer’s official website. |
| Nissha Medical (ex Graphic Controls) | SWAROPLATE Split Diathermy Pad, Adult, REM connector | 6000811N (ref. 1251H) | Comparable by category (not interchangeable 1:1) | Structurally very similar option: split plate with REM control, polyethylene foam (PE foam) backing, conductive hydrogel adhesive, Valleylab-REM connector and 3 m cable, for adult use. The backing measurement differs (200 x 106 mm versus 202 x 101 mm) and the adhesive surface (144 cm² versus 118 cm² active surface). Code and attributes verified in the manufacturer’s official catalogue. |
The cited references have been cross-checked against regulatory databases (GUDID/FDA) and official catalogues from each cited manufacturer. Although they coincide in function (return with REM control, Valleylab-type connector, adult and single-use), they differ in substrate, exact measurements and cable length, so they are not 1:1 interchangeable. There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders. Before any substitution, check field by field: dimensions and active surface, backing and hydrogel type, REM system, physical connector and compatibility with the installed electrosurgical generator.
Selection tips and variants of interest
- Check the generator plug: this reference with Valleylab-type connector is suitable for REM equipment with a Valleylab socket. If your generator uses a bipolar Ø6.3 mm socket, reference F7820W/6.3 maintains the same plate body (118 cm² with REM) with a 300 cm cable.
- If you prefer to work with a reusable plate cable, choose the cable-free version with tab connection F7820 (118 cm² with REM), compatible with cables type F7903 (Valleylab with REM) or F7902.
- For generators without REM control, the homologous alternative in the same format is F7805W/V (202 x 101 mm, 132 cm², without REM, 300 cm cable and Valleylab connection).
- Paediatric and neonatal populations: F7820PW/V (148 x 90 mm, 72 cm²) and F7820NW/V (88 x 74 mm, 33 cm²) with the same REM technology and 300 cm cable.
- To extend compatibility with other generators, the adapters F4828 (Valleylab-type connection to 4 mm plug) and F4829 (to 6.3 mm plug) can be used.
- Always apply to dry, intact, hair-free skin, on a well-perfused muscle area away from pacemakers, metal implants or prominent bony areas. Check the integrity of the individual packaging and the expiry date before each use: it is a single-use, non-sterile product.





Reviews