Description
1. Product Presentation
The disposable electrosurgery electrode Ref. F4052/TEF is the reference consumable when high-precision cutting and coagulation with minimal tissue adherence is required. Its PTFE-coated needle tip glides cleanly over the surgical bed, reduces carbonised eschar formation and avoids interruptions to clean the tip during the procedure. It is supplied in a box of 24 units with individually heat-sealed packaging, ready to open at the time of surgery; a sterile single-use solution that eliminates the risk of cross-contamination and the costs of resterilisation. Clinical stock available immediately for hospitals, clinics and ambulatory surgery centres.
2. Technical explanation and operation
The F4052/TEF electrode is the active electrode of a monopolar electrosurgery system: the radiofrequency current generated by the electrosurgical unit (ESU) travels to the needle tip and is concentrated at a minimal contact point, allowing fine incisions, precise dissection and spot coagulation of small vessels with reduced thermal damage to adjacent tissue.
- Needle tip Ø 0.75 mm: maximum energy concentration for precision cutting and haemostasis, ideal in dermatological surgery, minor surgery and fine dissection.
- PTFE coating: non-stick effect that minimises carbonisation and slough adherence, maintains conductivity and prolongs tip performance without frequent cleaning.
- Length 152 mm (±3 %), commercial designation 150 mm: wide reach for working in deep surgical fields with stability.
- Shaft 2.38 mm (3/32″) with anti-rotation hexagonal lock: universal fixation standard, compatible with the vast majority of pencils and electrosurgical units on the market (Valleylab type and compatible).
- Sterile single-use: sterilised by ethylene oxide (EO), eliminates the risk of cross-contamination.
3. Technical Specifications
| Reference / SKU | F4052/TEF |
| Product type | Disposable monopolar electrosurgery electrode, needle tip |
| Length | 150 mm (152 mm ±3 % per manufacturer’s catalogue) |
| Coating | Non-stick Teflon (PTFE) |
| Tip type | Needle Ø 0.75 mm |
| Electrode material | AISI stainless steel |
| Shaft diameter | 2.38 mm (3/32″) |
| Fixation system | Hexagonal anti-rotation lock |
| Compatibility | Handpieces with universal 2.38 mm (3/32″) connection, Valleylab type and compatible |
| Sterility | Sterile by ethylene oxide (EO), single-use |
| Latex | Latex-free |
| Presentation | Box of 24 units, individual heat-sealed packaging |
| Classification | Medical device Class IIb · CE marking (Directive 93/42/EEC, NB 2797) |
| Shelf life / storage | 4 years · 0–50 °C · RH 20–80 % |
Variants of the same family (Teflon coating, 2.38 mm shaft, box of 24 units):
| Reference | Length | Shape |
| F4044/TEF | 70 mm | Sphere Ø 4 mm |
| F4046/TEF | 70 mm | Blade |
| F4048/TEF | 70 mm | Needle |
| F4050/TEF | 150 mm | Blade |
| F4052/TEF | 150 mm | Needle |
| F4053/TEF | 100 mm | Blade |
| F4067/TEF | 150 mm | Sphere Ø 4 mm |
Compatibility note: verify that your pencil accepts a 2.38 mm (3/32″) shaft with hexagonal lock; the vast majority of electrosurgical units on the market (Valleylab, ConMed, Bovie, Erbe and compatible) accept it.
4. Equivalences and Cross-References
No official cross-reference table from the manufacturer has been found in public sources that validates an exact 1:1 equivalence of this electrode with those of other brands. The following rows are functional comparisons verified against official catalogues, manufacturer websites and authorised distribution, and should be treated as comparable at category level, not 1:1 interchangeable without validation from the technical department.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Prima Medical (United Kingdom) | Nonstick needle electrode, PTFE coated | PMS 2934 (needle 152 mm, pack of 10) | Comparable by category (not interchangeable 1:1) | 152 mm needle with PTFE non-stick coating, same length as the F4052/TEF; they differ in presentation (pack of 10 vs 24) and manufacturer. Code verified in the authorised distribution catalogue of the brand (Eurosurgical). |
| Prima Medical (United Kingdom) | Nonstick needle electrode shielded tip, PTFE coated | PMS 2935 (needle 152 mm with shielded tip, pack of 10) | Comparable by category (not interchangeable 1:1) | Same 152 mm non-stick needle with additional tip insulation (shielded tip); they differ in insulation and presentation. Code verified in the authorised distribution catalogue of the brand. |
| Medical Disposables UK | Non Stick PTFE Coated Electrodes, single use, sterile | MD2406-23 (needle 15 cm, shaft 2.4 mm, box of 12) | Comparable by category (not interchangeable 1:1) | Sterile single-use needle electrode with PTFE coating and standard 2.4 mm shaft; very similar length (15 cm vs 15.2 cm). They differ in presentation (12 vs 24) and exact reference. Code verified on the distributor’s website. |
| Medtronic / Valleylab (Covidien) | Valleylab™ stainless steel electrode, extended needle | E15526 (extended needle 16.51 cm / 6.5″, shaft 3/32″, box of 50) | Comparable by category (not interchangeable 1:1) | Monopolar needle electrode, single-use, with standard 3/32″ shaft and hexagonal lock; they differ in needle length (165 mm vs 152 mm), material (stainless steel without PTFE coating) and presentation (box of 50). Code verified in authorised distribution of the brand. |
No equivalence table validated by the manufacturer exists; consult with the technical department before use in tenders. Before any substitution, check field by field: total length (152 mm / 150 mm), needle diameter (0.75 mm), shaft diameter (2.38 mm / 3/32″), fixation system (hexagonal lock), coating (Teflon/PTFE), sterility and presentation. The third-party codes cited have been verified in public sources and correspond to electrodes of the same category, not certified 1:1 equivalents.
5. Selection tips and variants of interest
The choice of tip geometry should be based on the surgical technique and the tissue to be treated. The needle of the F4052/TEF is indicated for precision dissection, fine incisions and spot haemostasis, with wide reach thanks to its 150 mm length. If access is more superficial, the reference F4048/TEF offers the same needle tip with PTFE coating in 70 mm; for cutting, the PTFE family is completed with blades F4046/TEF (70 mm), F4053/TEF (100 mm) and F4050/TEF (150 mm); and for surface coagulation, with spheres F4044/TEF (70 mm) and F4067/TEF (150 mm).
In applications where cost per procedure is prioritised, the stainless steel version F4052 offers the same needle geometry without coating; the titanium version F4052T (152 mm) provides a non-stick alternative with higher corrosion resistance, and the tungsten series F4051/TU covers needle configurations with insulating sleeve. If a complete pencil with the long needle fitted is preferred, the reference F4797/AL incorporates the F4052 needle from the factory. Always verify that your pencil accepts a 2.38 mm (3/32″) shaft with hexagonal lock; this is a single-use product: do not resterilise or reuse. For institutional volumes or tenders, consult our technical-commercial department.





Reviews
There are no reviews yet.