Connection cable for reusable neutral plate FIAB · F7922/WB
1. Product Presentation
We present the original FIAB connection cable (Ref. F7922/WB) for reusable neutral plates, an essential accessory to complete the monopolar circuit of your electrosurgery with maximum reliability. With a length of 500 cm, 6.3 mm mono jack connector and without junction box configuration, this cable connects the return plate directly to the electrosurgical unit and allows the neutral electrode to be reused in multiple procedures after cleaning.
It is the usual choice in operating theatres, minor surgery clinics, dermatology, dentistry and veterinary clinics that wish to reduce healthcare waste and the recurring cost of single-use electrodes, while maintaining a safe and stable return contact.
2. Technical explanation
In monopolar electrosurgery, the high-frequency current leaves through the active electrode (pencil), passes through the patient’s tissue and must return to the generator via a low current density path: the neutral plate or return electrode. The quality of that path depends on both the plate and the cable that connects it to the electrosurgical unit.
This FIAB F7922/WB cable guarantees that connection with a 6.3 mm mono jack connector and without junction box (WB, without derivation box), that is, a direct cable path between the plate and the equipment. When working with reusable neutral plates equipped with a 4 mm socket, the plate-cable assembly ensures a low and stable contact impedance, an essential condition to avoid current density concentrations that could lead to patient burns. It is a reusable accessory: it must be cleaned after each use, visually inspected (no cuts, cracks or deterioration of the insulation) and its continuity periodically verified before each procedure.
3. Technical Specifications
| Characteristic | Value |
|---|---|
| Reference FIAB | F7922/WB |
| Packaging | Single unit |
| Units per box (web) | 1 |
Product features
| Characteristic | Value |
|---|---|
| Brand / Manufacturer | FIAB / FIAB SpA (Vicchio, Florence, Italy) |
| Product type | Connection cable for reusable neutral plate (return electrode) |
| Length | 500 cm |
| Connector | 6.3 mm mono jack |
| Junction box | Without junction box |
| Type of use | Reusable |
| Compatibility | Reusable neutral plates FIAB with 4 mm socket: F7930 (with REM system) and F7915 (without REM) |
Available references
| Reference | Description | Length |
|---|---|---|
| F7922/WB | Cable with 6.3 mm mono jack connector, without junction box | 500 cm |
4. Equivalences and Cross-References
This cable belongs to the FIAB range of connection cables for reusable neutral plates. Reference F7922/WB corresponds to the version without junction box of cable F7922 (which does incorporate it). Complete with these references from the same commercial family, depending on the generator connector installed in your centre:
| Reference | Description |
|---|---|
| F7922 | Universal cable, 6.3 mm mono jack connector, with junction box, 500 cm |
| F7922/4 | Cable with 4 mm plug, 500 cm |
| F7922/24 | Cable with double 4 mm plug, 500 cm |
| F7923 | Valleylab type cable (ESU with REM), 500 cm |
| F7923/F | Valleylab type cable (ESU without REM), 500 cm |
| F7924 | Special 6.3 mm mono jack cable for ERBE (ACC, ICC, VIO, T), 500 cm |
This cable is intended for use with the reusable silicone neutral plates from the same range: plate F7930 (200 x 150 mm, 250 cm², with REM system and 4 mm socket) and plate F7915 (without REM system, same 4 mm socket). There is no official equivalence table validated by the manufacturer with cables from other brands; before any replacement, confirm with the technical department the compatibility of the connector with your generator.
5. Selection tips and variants of interest
Check your equipment’s connector: reference F7922/WB uses a 6.3 mm mono jack connector and does not incorporate a junction box. If your installation requires an intermediate connection box, consider reference F7922 (with junction box).
Other connector configurations: if your equipment uses a single or double 4 mm plug, consider references F7922/4 and F7922/24; if you use a Valleylab type connector, references F7923 (with REM) or F7923/F (without REM); for ERBE generators from the ACC, ICC, VIO and T series, reference F7924.
Compatible plate: use it with reusable FIAB plates with 4 mm socket (F7930 with REM or F7915 without REM) to ensure a stable return contact.
Maintenance: clean the cable after each use with the products indicated by the manufacturer, dry it completely and avoid sharp bends; check the insulation and continuity before each procedure and replace it at any sign of degradation.
Institutional purchases: for operating theatre fittings or volume orders with special B2B conditions, consult our technical-commercial department.