Description
1. Product Presentation
The disposable electrosurgery electrode Ref. F4053/TEF is the reference consumable for monopolar cutting and coagulation procedures that demand precision, hygiene and consistent performance. Its 100 mm PTFE (Teflon)-coated blade glides over tissue without dragging carbonised eschar, reduces interruptions to clean the tip and maintains stable performance throughout the entire intervention. Each box contains 24 sterile single-use units, ready to open at the time of surgery, eliminating the risk of cross-contamination and resterilisation costs. Available with clinical stock for hospitals, clinics, outpatient major surgery centres and minor surgery practices.
2. Technical explanation and operation
The F4053/TEF is the active electrode of a monopolar electrosurgery system: the radiofrequency current generated by the electrosurgical unit (ESU) travels to the blade tip and concentrates on the edge, allowing guided incisions and effective haemostasis in the same pass with less thermal damage to adjacent tissue. The circuit closes through the neutral plate (dispersive) placed on the patient; depending on the selected waveform, the predominant effect will be cutting, coagulation or mixed.
- 100 mm blade: balanced reach for general surgery, dermatology, minor surgery and outpatient procedures.
- Teflon (PTFE) coating: non-stick effect that minimises carbonisation and adherence of slough, maintains conductivity and prolongs tip performance without frequent cleaning.
- 2.38 mm (3/32″) shaft with anti-rotation hex lock: universal fixing standard, compatible with virtually all pencils and electrosurgical units on the market (Valleylab type and compatible).
- Sterile single-use: sterilised with ethylene oxide (EO), latex-free, ready to use in each procedure.
3. Technical Specifications
| Specification | Detail |
|---|---|
| Reference / SKU | F4053/TEF |
| Product type | Disposable monopolar electrosurgery electrode |
| Length | 100 mm |
| Coating | Non-stick Teflon (PTFE) |
| Tip type | Blade (blade) |
| Electrode material | AISI stainless steel |
| Shaft diameter | 2.38 mm (3/32″) — universal standard |
| Fixation system | Hexagonal anti-rotation lock |
| Compatibility | Handpieces with universal connection 2.38 mm (3/32″), Valleylab type and compatible |
| Use | Disposable, single-use |
| Sterility | Sterilised with ethylene oxide (EO), individually heat-sealed packaging |
| Latex | Latex-free |
| Presentation | Box of 24 units |
| Shelf life / storage | 4 years from date of manufacture · 0–50 °C · relative humidity 20–80 % |
| Classification | Medical device class IIb · CE marking (Directive 93/42/EEC, notified body 2797) |
Variants of the same family (Teflon coating, 2.38 mm shaft, box of 24 units):
| Reference | Length | Shape |
|---|---|---|
| F4044/TEF | 70 mm | Sphere Ø 4 mm |
| F4046/TEF | 70 mm | Blade |
| F4046S/TEF | 70 mm (65 mm sleeve) | Blade |
| F4048/TEF | 70 mm | Needle |
| F4050/TEF | 150 mm | Blade |
| F4050S/TEF | 150 mm (sleeve 145 mm) | Blade with sleeve |
| F4052/TEF | 150 mm | Needle |
| F4053/TEF | 100 mm | Blade (this product) |
| F4053S/TEF | 100 mm (95 mm sleeve) | Blade with sleeve |
| F4067/TEF | 150 mm | Sphere Ø 4 mm |
4. Equivalences and Cross-References
The reference F4053/TEF belongs to the family of disposable PTFE-coated electrodes with a 2.38 mm shaft. No official cross-reference table from the manufacturer has been found in public sources that validates an exact 1:1 equivalence with other brands. The following rows are functional comparisons verified against official manufacturer catalogues and the GUDID/FDA regulatory database, and should be treated as comparable at category level, not interchangeable 1:1 without validation from the technical department.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
|---|---|---|---|---|
| Prima Medical (United Kingdom) | NonStick™ blade electrode, PTFE-coated, 100 mm blade, non-shielded tip | PMS 2925 (pack of 10) · hex-lock variant PMS 2925A | Comparable by category (not interchangeable 1:1) | Same 100 mm blade with anti-adherent PTFE coating and double insulation; the PMS 2925A variant incorporates hex lock like the F4053/TEF. They differ in presentation (pack of 10 vs. 24) and manufacturer. Code and attributes verified in the official Prima Medical catalogue (Electrodes Catalogue) and authorised distribution. |
| Prima Medical (United Kingdom) | NonStick™ blade electrode with shielded tip, 100 mm blade, PTFE-coated | PMS 2926 (pack of 10) · hex-lock variant PMS 2926A | Comparable by category (not interchangeable 1:1) | Same 100 mm blade with anti-adherent PTFE coating and additional tip insulation, function equivalent to the insulating sleeve of the S series; they differ in insulation, presentation (pack of 10) and manufacturer. Code verified in the official brand catalogue. |
| Aspen Surgical / Bovie (USA) | Resistick II™ Coated Extended Blade Electrode 4″ (10.16 cm) | ES55T (box of 12) | Comparable by category (not interchangeable 1:1) | Disposable sterile extended blade electrode with anti-adherent PTFE coating type Resistick II; very similar length (101.6 mm vs. 100 mm) and standard 3/32″ (≈2.3 mm) shaft. They differ in presentation (box of 12 vs. 24) and manufacturer. Code and attributes verified in GUDID/FDA (class II, sterile) and manufacturer catalogue. |
There is no equivalence table validated by the manufacturer; consult with the technical department before using in a tender. Before any substitution, check field by field: blade length (100 mm), coating (Teflon/PTFE), material (AISI stainless steel), shaft diameter (2.38 mm / 3/32″), fixing system (hex lock), sterility and presentation. Third-party codes cited have been verified in public sources and correspond to electrodes of the same category, not certified 1:1 equivalents. As a functional comparison without anti-adherent coating there are stainless steel blade electrodes such as Valleylab™ E1551-6 (extended blade, 3/32″ shaft) and ConMed blades with hex hub (series 1381xx); lacking PTFE coating they do not meet the material equivalence rule and should not be treated as direct substitutes without technical validation.
5. Selection tips and variants of interest
The 100 mm blade of the F4053/TEF offers a balanced reach, ideal for general surgery, dermatology and minor surgery procedures, both open and outpatient. If you need to protect adjacent tissues in delicate areas or deep accesses, the reference F4053S/TEF offers the same 100 mm blade with Teflon coating and 95 mm insulating sleeve. For more superficial accesses, the F4046/TEF (70 mm blade) is the option from the same family; if more reach is required, the F4050/TEF (150 mm blade) and F4050/16TEF (165 mm) extend the working radius.
The non-stick coating range is completed with needles (F4048/TEF of 70 mm and F4052/TEF of 150 mm) for precision dissection and pinpoint haemostasis, and with spheres (F4044/TEF of 70 mm and F4067/TEF of 150 mm) for contact coagulation of large surfaces. Always verify that your pencil accepts a 2.38 mm (3/32″) shaft with hexagonal locking: electrosurgical pencils from Valleylab, ConMed, Bovie, Erbe and compatible models accept it. This is a single-use product: do not re-sterilise or reuse. For institutional volumes or tenders, please consult our technical-commercial department.





Reviews