Description
1. Wireless ear thermometer for your M10 and M20 monitor
Complete the monitoring of your facility with the official infrared ear thermometer from the M10 and M20 vital signs monitor family. It is an original accessory from the manufacturer Medical Econet (Germany, reference 21.50-6011) that adds infrared body temperature measurement to the monitor without the need for cables: the result is sent via Bluetooth and appears directly on the device screen. A professional, fast and convenient solution for hospital wards, emergency departments, outpatient clinics, primary care and intra-hospital transport.
2. Technical explanation of the equipment
The thermometer measures body temperature via thermal radiation captured in the ear canal, a fast and reliable clinical method. The probe detects infrared energy from the eardrum and converts it into a temperature value that is displayed on the device and transmitted wirelessly (Bluetooth) to the compatible M10 or M20 monitor, integrating into the device’s usual workflow. Its ergonomic design allows comfortable use in adults and children, and the use of disposable protective covers reduces the risk of cross-contamination between patients. Measurement is completed in 2–3 seconds, with an accuracy of ±0.2 °C and a resolution of 0.1 °C.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Product type | Clinical infrared ear thermometer, wireless |
| Measurement method | Infrared (thermal radiation from the ear canal) |
| Connectivity | Bluetooth, wireless communication with the monitor |
| Compatibility | Vital signs monitors M10 and M20 |
| Temperature range | 34.0 – 42.2 °C |
| Accuracy | ±0.2 °C |
| Screen resolution | 0.1 °C |
| Measurement time | 2–3 seconds |
| Included accessories | 20 disposable protective covers |
| Weight | 0.085 kg (shipping weight) |
| Manufacturer / Distributor | Medical Econet GmbH (Germany) |
| Manufacturer reference | 21.50-6011 (SKU Cahnos: MEC21.50-6011) |
Data verified against the manufacturer’s technical documentation (M10 model data sheet and official Medical Econet website).
4. Equivalences and Cross-References
There is no manufacturer-validated equivalence table cross-referencing reference 21.50-6011 with third-party thermometers for 1:1 replacement: it is a specific accessory that communicates wirelessly with the M10 and M20 monitors and cannot be exchanged for a conventional ear thermometer. The following products belong to the same category (clinical infrared thermometers) and are offered as a comparative guide; they must be evaluated field by field before any replacement:
| Manufacturer / Brand | Family / Model | Code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Italian brand | Pocket ear thermometer | GM25579 | Comparable by category (not interchangeable 1:1) | Standalone infrared ear thermometer, without Bluetooth connection to monitors; range 34–44 °C, accuracy ±0.2 °C and memory of 10 measurements. Confirmed in technical data sheet and manual (ISO 80601-2-56). |
| Italian brand | Non-contact infrared thermometer model A200 | GM25582 | Comparable by category (not interchangeable 1:1) | Non-contact infrared measurement (forehead/object), body range 32.0–42.9 °C and memory of 25 measurements; no wireless integration with vital signs monitors. Confirmed in instruction manual. |
| Italian brand | Multipurpose non-contact infrared thermometer | GM25583 | Comparable by category (not interchangeable 1:1) | Non-contact body thermometer with dual mode (surface 0–100 °C and body 34–43 °C) and automatic shutdown after 18 s; does not communicate via Bluetooth with M10/M20 monitors. Confirmed in instruction manual. |
| Distribution Cahnos | Infrared forehead and ear thermometer | 1371002 (IU-TDIG-11) | Comparable by category (not interchangeable 1:1) | Dual forehead/ear thermometer without monitor connectivity; accuracy ±0.2 °C between 35–42 °C and memory of 20 measurements. Confirmed in technical data sheet (EN 60601-1). |
There is no manufacturer-validated equivalence table authorising the direct cross-reference of reference 21.50-6011 with the models mentioned; consult the technical department before using this reference in tenders or replacing equipment in service.
5. Selection tips and variants of interest
This thermometer is the right choice when your facility already has an M10 or M20 vital signs monitor and you want to complete temperature measurement without cables: the result is automatically integrated into the device. Remember to replenish the disposable protective covers: the pack of covers for the M10/M20 thermometer (200 units) ensures prolonged hygienic coverage in daily use with multiple patients. For equipment without a wireless temperature module or for independent use from a monitor, consider the standalone infrared thermometers in the catalogue. Always check the compatibility of the receiver (M10 or M20) and complete your supply with the family accessories (SpO2 probes, NIBP cuffs and extension tubes). For institutional orders, supplies or tenders, contact our technical-commercial department at Cahnos.