Description
1. Commercial Introduction
The replacement extension cable (ref. 34348) is the original accessory your centre needs to make oxygen saturation monitoring more flexible. Designed and manufactured, this intermediate cable connects between the SpO2 pulse oximetry catheter and the monitor or pulse oximeter, extending the working range and allowing the sensor to be placed freely on the patient. As it is a spare part from the same manufacturer, it maintains signal integrity and full compatibility with the equipment that uses the catheters with codes 34345, 34347 and 34349.
2. Technical Explanation
In SpO2 monitoring, the catheter captures the optical signal from the capillary bed and transmits it to the monitor to calculate oxygen saturation and pulse rate. In many clinical configurations, the catheter cable length is insufficient to comfortably reach the measurement point, especially when the monitor is fixed to an infusion stand, the head of the bed, or a transport trolley. This 1 m extension cable acts as an intermediate element between the catheter and the equipment, facilitating placement of the sensor on the patient’s hand, foot or earlobe. It is a passive connection component that does not alter the measurement and is essential as a spare part to keep monitoring operational for compatible pulse oximeters.
3. Technical Specifications
Replacement 1 m extension cable for SpO2 pulse oximetry catheters with codes 34345, 34347 and 34349 from the manufacturer.
| Manufacturer | GIMA |
|---|---|
| Manufacturer reference | 34348 (SKU Cahnos: GM34348) |
| Function | Extension cable for SpO2 catheters (spare part) |
| Cable length | 1 m |
| Compatibility | SpO2 Catheters Ref. 34345, 34347 and 34349 |
| Sales unit | 1 pc |
| Device type | Medical device (Medical device) |
| Device class | I |
| CND | Z1203020280 |
| EAN | 6941900601963 |
Available references
| Reference | Description | Sales unit |
|---|---|---|
| GM34348 | Replacement extension cable, 1 m | 1 pc |
4. Equivalences and Cross-References
Reference 34348 corresponds to the original extension cable intended for pulse oximetry catheters with codes 34345 (adult clip-type catheter), 34347 (paediatric catheter) and 34349. These catheters are used with the pulse oximeters and vital signs monitors of the Ref. 34341, 33698 and 34342 family. There is no official equivalence table validated by the manufacturer that cross-references this reference with third-party extension cables: extension cables for SpO2 catheters from other brands may have differences in connector, pinout and calibration, so they should only be replaced after confirming exact compatibility with our technical-commercial department. To guarantee system integrity, the use of the original spare part is recommended.
5. Selection tips and variants of interest
Always verify that the SpO2 catheter of your equipment corresponds to codes 34345, 34347 or 34349 before incorporating this cable into your stock. This cable is sold per unit as a spare part: consider having a safety unit in services with high patient turnover, as continuous handling of cables is one of the most common causes of wear in monitoring systems. If you also need to extend the range in other configurations, consult the rest of the extension cables for SpO2 catheters and vital signs monitor accessories in the Cahnos catalogue. For institutional orders, scheduled replenishments or tenders, contact the technical-commercial department of Cahnos for B2B conditions and compatibility confirmation.