Description
1. Introduction
The reusable paediatric SpO2 catheter (ref. 35054) is the optional monitoring accessory indicated for the pulse oximeters Ref. 35048 (OXY-55) and 35111 from serial number 25050500001. Designed as a replacement or additional equipment supply, it is specifically intended for paediatric patients and guarantees reliable, continuous readings of blood oxygen saturation (SpO2) and pulse rate in high-turnover clinical environments.
Being a reusable sensor, it can be cleaned and reused between patients following the manufacturer’s hygiene instructions, which reduces the cost per use compared with disposable catheters and simplifies stock management in the department. It is the right part both for replacing a catheter worn out by continued use and for expanding the accessory set of your pulse oximeter.
2. Technical explanation
Pulse oximetry is a non-invasive optical technique that measures the functional oxygen saturation of arterial haemoglobin by spectrophotometry: the catheter emits light at two wavelengths (red and infrared) through the patient’s vascular bed and a photodetector quantifies the differential absorption of light according to the degree of blood oxygenation. From that signal, the pulse oximeter Ref. 35048 (OXY-55) or 35111 processes and displays in real time the SpO2 value, pulse rate and, in the case of the OXY-55, the plethysmographic curve and the perfusion index (PI).
This external paediatric-type catheter integrates the emitter and the photodetector in a single compact element adapted to the child’s anatomy, allowing comfortable and stable attachment during occasional or continuous monitoring. As it is indicated for the 35048 and 35111 devices from serial number 25050500001, it is recommended to confirm the exact model and serial number of the device before replacement to ensure compatibility of the connector and communication protocol.
3. Technical Specifications
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
| Device type | Medical device |
| Device class | II B |
| CND | C900301 |
| EAN | 6945040110255 |
Technical features
| Manufacturer reference | 35054 |
|---|---|
| Sensor type | Reusable paediatric SpO2 catheter |
| Patient population | Paediatric |
| Use | Reusable (replacement / optional accessory) |
| Compatibility | Pulse oximeters Ref. 35048 (OXY-55) and 35111, from serial no. 25050500001 |
| Measured parameters | Oxygen saturation (SpO2) and pulse rate |
| Request | (see B2B conditions) |
Available references
| Reference | Compatible model / equipment | Sales unit |
|---|---|---|
| 35054 | Pulse oximeters Ref. 35048 (OXY-55) and 35111 (from SN 25050500001) | 1 pc |
4. Equivalences and Cross-References
Reference 35054 is the original code for this reusable paediatric SpO2 catheter, intended as an optional accessory for the 35048 and 35111 pulse oximeters. Within the same range of reusable paediatric catheters, references 34347 and 33731 are also available, used in other pulse oximeters from the same manufacturer, which share a paediatric and reusable nature but require prior verification of the connector and equipment model before any exchange.
There is no equivalence table validated by the manufacturer that cross-references this item with SpO2 sensors from other manufacturers (Nonin, Masimo, Nellcor, etc.), since compatibility depends on the connector type and the electronic protocol of each device. It is recommended to contact the technical-commercial department of Cahnos to confirm exact compatibility before considering a replacement, especially in tenders or maintenance contracts.
5. Selection tips and variants of interest
Check that your pulse oximeter corresponds to models 35048 (OXY-55) or 35111 and that its serial number is equal to or greater than 25050500001 before placing the order. As this is a reusable catheter, follow the manufacturer’s cleaning and disinfection instructions between patients and periodically inspect the cable and contact area to avoid erroneous readings.
To complete the equipment of your pulse oximetry fleet, the Cahnos catalogue offers other catheters from the same manufacturer family: the reusable adult SpO2 catheter for the 35048 (ref. 35049), the clip paediatric catheter for the OXY-10 (ref. 35096), the rubber paediatric catheter for the 35095 (ref. 35097), the neonatal Y-type catheter for the 35095 (ref. 35099) and the 10-40 kg paediatric catheter for the 35152 and 35213 devices (ref. 35215). It is recommended to have at least one spare unit for each pulse oximeter in use to minimise downtime. For large orders you can request a quote: contact the technical-commercial team of Cahnos for B2B conditions, availability and delivery times.






Reviews