Finger Pulse Oximeter OXY-1 with LED Display – SpO2 and Pulse Rate Monitor (Ref. 35070) · Manual GB, PT, GR, DK, NL, RO

13,30 €

The OXY-1 finger pulse oximeter (ref. 35070) non-invasively measures blood oxygen saturation (SpO2) and pulse rate (PR) using a sensor forceps placed on the finger. Designed for both home and professional use in clinics, health centres and hospitals, it features an LED screen with direct SpO2 and pulse reading, bar graph, low battery indicator and automatic shut-off after 5 seconds. SpO2 range 0-100% (resolution 1%) with accuracy ±2% between 70-100%; pulse rate 30-250 bpm with accuracy ±2 bpm or ±2%. Class II B medical device (CND Z1203020408, EAN 8023279350708). For large orders you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM35070

Description

1. Commercial presentation

The OXY-1 finger pulse oximeter (ref. 35070) is a non-invasive medical device of the forceps type, designed to quickly and reliably measure oxygen saturation (SpO2) and pulse rate (PR) by placing the sensor on the patient’s finger. A European benchmark in medical equipment, this oximeter is suitable for both home use and professional use in clinics, health centres and hospitals. It can also be used before or after sports practice, although its use during exercise is not recommended. This variant is supplied with a user manual in English (GB), Portuguese (PT), Greek (GR), Danish (DK), Dutch (NL) and Romanian (RO). For large orders you can request a quote: ask your Cahnos technical-commercial team for conditions.

2. Technical explanation of the equipment

The OXY-1 measures arterial haemoglobin oxygen saturation and pulse rate using transmission pulse oximetry technology: a forceps with LED emitters and a photodetector is placed on the finger and, based on the variations in red and infrared light absorption associated with blood flow, the device calculates SpO2 and pulse rate (PR) values in real time, also displaying a pulse bar graph.

  • Display of SpO2 and pulse rate values, with bar graph.
  • Low battery indicator (low voltage).
  • Automatic shut-off after 5 seconds to maximise battery life.
  • Capable of correctly displaying SpO2 and pulse in low perfusion conditions (pulse filling ratio 0.4%).

3. Technical Specifications

3.1 Measurement parameters

Parameter Value
Display mode LED display
SpO2 – Range 0-100% (resolution 1%)
SpO2 – Accuracy 70-100%: ±2%; below 70%: not specified
Pulse rate (PR) – Range 30-250 bpm (resolution 1 bpm)
Pulse rate (PR) – Accuracy ±2 bpm or ±2% (whichever is greater)
Low perfusion measurement Correct SpO2 and pulse with pulse filling ratio 0.4%; SpO2 error ±4%, PR error ±2 bpm or ±2% (whichever is greater)
Energy consumption Less than 25 mA – Voltage: DC 2.6 V – 3.6 V
Battery life Two batteries for continuous operation up to 24 hours
Safety type Internal battery, BF type
Dimensions – Weight 60 x 30.5 x 32.5 mm – 50 g (with two batteries included)

3.2 Available references

Reference Model Sales unit
35070 OXY-1 Finger Oximeter (GB, PT, GR, DK, NL, RO) 1 pc

3.3 Product data

Manufacturer GIMA
Sales unit 1 pc
Device type Medical device
Device class II B
CND Z1203020408
GMDN 17148
EAN 8023279350708

4. Equivalences and Cross-References

The OXY-1 pulse oximeter (ref. 35070) belongs to the OXY series finger pulse oximeter family and shares CND classification (Z1203020408) and device class II B with other models in the range. The manufacturer does not declare an official equivalence table cross-referencing this model with models from other brands, so it must not be replaced by equipment from other manufacturers without prior technical validation from the Cahnos department. Within the catalogue itself, references from the same family with identical technical specifications are identified (only the manual language changes):

Model Reference Related items
OXY-1 Finger Oximeter (IT, HR, FI, LV, BG, Arabic) 35069 Same technical specifications (not interchangeable 1:1)
OXY-1 Finger Oximeter (GB, PT, GR, DK, NL, RO) 35070 Product of this data sheet
OXY-1 Finger Oximeter (FR, ES, DE, PL, CZ, SE) 35071 Same technical specifications (not interchangeable 1:1)
OXY-2 Finger Oximeter (GB, FR, IT, ES, PT, GR) 35072 Same technical specifications (not interchangeable 1:1)

5. Selection tips and variants of interest

Choose the OXY-1 (ref. 35070) when you need a simple and reliable finger pulse oximeter for spot-check measurement of SpO2 and pulse rate in home use, clinics, primary care or emergency services. Its direct-read LED screen, low battery indicator and automatic shut-off make it a practical solution for monitoring vital signs in adult patients. This variant includes a manual in English, Portuguese, Greek, Danish, Dutch and Romanian, ideal for centres with multilingual users.

If you need a version for the paediatric population, consider the OXY-0 Pediatric (ref. 35056 or 35057); for more clinical information with perfusion index (PI) and alarms, the OXY-4 (ref. 35091/35092); for telemonitoring with Bluetooth connectivity and OLED screen, the OXY-8 (ref. 35077); and for high-end portable monitoring, the OXY-100 (ref. 34342) or the OXY-110 (ref. 34341), available in the Cahnos catalogue. For centre-wide supplies, equipment projects or special supply conditions, request a quote from the Cahnos technical-commercial team, quoting reference 35070.

Additional information

Manufacturer reference

35070

Model

OXY-1 Finger Oximeter (GB, PT, GR, DK, NL, RO)

Device type

Medical device

CND code

Z1203020408

GMDN code

17148

EAN

8023279350708

Display

LED display

Measured parameters

SpO2 and pulse rate (PR)

SpO2 range

0-100% (resolution 1%)

Spo2 accuracy

±2% (70-100%); below 70% not specified

Pulse rate range

30-250 bpm (resolution 1 bpm)

Pulse rate accuracy

±2 bpm or ±2% (whichever is greater)

Low perfusion measurement

Pulse filling ratio 0.4%; SpO2 error ±4%, PR error ±2 bpm or ±2% (whichever is greater)

Energy consumption

Less than 25 mA; DC voltage 2.6 V – 3.6 V

Battery life

Up to 24 hours of continuous operation with two batteries

Safety classification

Internal battery, BF type applied part

Dimensions

60 x 30.5 x 32.5 mm

Weight

50 g (with two batteries included)

Functions

SpO2 and PR display with bar graph; low battery indicator; automatic shut-off after 5 seconds

Languages

GB, PT, GR, DK, NL, RO

Use

Home and professional use (clinic, health centre and hospital); before or after exercise, not recommended during

Presentation

1 unit (1 pc)

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II b

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF