Description
The Monitor defibrillator ME PAD Máster Estándar I (Ref. 30.10-4452) is the professional solution of the ME PAD Master range for services requiring a single device covering the entire advanced life support cycle: manual defibrillation, cardiac monitoring, AED mode and non-invasive pacing, with a built-in thermal printer as standard. Designed for intensive care units, emergency rooms, ambulances and centres with continuous critical activity, it is supplied per unit with standard accessories included and a 24-month warranty.
Technical explanation of the equipment
The device delivers a truncated exponential biphasic waveform with impedance compensation: the delivered energy is adapted in real time to the patient’s thoracic impedance (25–200 ohms), maximising shock efficacy and minimising myocardial damage. The energy range is from 1 to 360 joules, with automatic adjustment depending on whether adult or paediatric patient is configured. Its four operating modes cover the entire care process: manual defibrillation with energy selection by the professional, monitoring with 3/5-lead ECG for rhythm diagnosis, AED mode with automatic analysis and operator guidance, and cardiac pacing for temporary treatment of bradycardias. The 8.4-inch LCD TFT display (800 x 600 pixels) shows the signals with total clarity and the built-in thermal printer allows recording and archiving events for clinical documentation.
Technical specifications
| Product type | Professional monitor defibrillator (defibrillation + monitor + AED + pacing, all in one) |
| Model | ME PAD Master Standard I (Ref. 30.10-4452) |
| Waveform | Biphasic truncated exponential with impedance compensation |
| Energy range | From 1 to 360 joules |
| Patient impedance | 25–200 ohm; automatic adult/child energy change |
| Operating modes | 4 modes: defibrillation, monitor, AED and cardiac pacing |
| ECG function | 3/5 selectable leads |
| Display | 8.4” TFT LCD with 800 x 600 pixel resolution |
| Printer | Integrated thermal (standard) for event recording |
| Battery | Lithium-ion, 14.5 V / 6600 mAh |
| Options | EtCO2 available depending on configuration |
| Position in the range | Intermediate level: adds the standard printer to the basic platform; the Advance (30.10-4450) additionally incorporates 12-lead ECG, NIBP/Temp and EtCO2 |
| Interface languages | English, Czech, Hungarian, Greek, Polish, Lithuanian, Russian and Norwegian |
| Standard accessories | Adult pads, battery and carry bag |
| Dimensions | 310 x 290 x 215 mm (width x length x height) |
| Weight | 6.5 kg |
| Warranty | 24 months |
| Regulatory standard | CE marking (Directive 93/42/EEC / MDD) |
Equivalences and cross-references
The ME PAD Máster Estándar I falls into the segment of manual defibrillators with monitor (biphasic monitor defibrillator for advanced life support). Cross-references have been checked against the technical data sheet, official catalogue or documentation of the cited manufacturer; no substitution should be applied without prior verification of compatibility with your workflow and installed base of consumables.
| Manufacturer / Brand | Family / Model | Reference Code / SKU | Equivalence Level | Technical Differences / Remarks |
| Bexen Cardio | REANIBEX 800 (monitor defibrillator) | REA800 (distribution catalogue ref.; confirm with Bexen) | Comparable by category (not interchangeable 1:1) | Manual and automated biphasic up to 360 J, 8.4” display (800 x 600), synchronised cardioversion, non-invasive pacemaker and 3/5/10/12-lead ECG. More modular and multiparametric (SpO2 Masimo Rainbow, Oridion Microstream capnography, NIBP SunTech), with 12 V NiMH battery; dimensions 300 x 260 x 350 mm and 7.6 kg in basic configuration. Same segment with a higher level of monitoring. |
| Cardioline (et medical devices) | elife700 (monitor/defibrillator) | ELIFE700 (official manufacturer model) | Comparable by category (not interchangeable 1:1) | Truncated exponential biphasic waveform with impedance compensation, manual and AED modes, with optional non-invasive pacemaker and pulse oximetry. Energy range up to 200 J (compared to 360 J), 320 x 240 pixel display (compared to 800 x 600) and NiMH battery. Dimensions 195 x 249 x 310 mm and 6.3-7.2 kg; 50 mm thermal printer. Compatible with multifunction patches from the same family. |
There is no equivalence table validated by the manufacturer that allows replacing this device with a monitor defibrillator of another brand: the electrode connector, analysis algorithm and interface are proprietary. Any comparison with other systems in the same segment (Stryker/Physio-Control LIFEPAK families, ZOLL R Series, Mindray BeneHeart or Schiller) must be understood as comparable at category level, not interchangeable 1:1, and requires confirming consumable, electrode geometry, maximum energy, algorithms and regulatory classification against each manufacturer’s IFU. Consult with the technical department of Cahnos before using in a tender.
Selection tips and variants of interest
Before choosing a configuration, assess the monitoring level your service needs: the ME PAD Máster Básico (Ref. 30.10-4451) covers the essential 3/5-lead ECG function; this Máster Estándar I (Ref. 30.10-4452) adds the standard printer on the same platform; the Máster Standard II (Ref. MEPAD STII) expands monitoring capabilities and offers the EtCO2 option; and the ME PAD Máster Advance (Ref. 30.10-4450) is the top variant, with 12-lead ECG, NIBP/Temperature and EtCO2. For training and demonstrations, the ME PAD Trainer kit (Ref. 31.10-4310) replicates the device handling in drills. Periodically replenish consumables: multifunction defibrillation pads for adults and paediatrics, thermal recording paper for the built-in printer and spare battery to ensure continuous operability. Check the charge status of the lithium-ion battery during scheduled inspections and keep the device in the included carrying bag. For large volume orders, fleet allocations or public tenders, contact the technical department of Cahnos to confirm exact configuration, options and lead times.





Reviews
There are no reviews yet.