Description
1. Commercial Introduction
Keep your defibrillator always ready to act with this pair of standard adult defibrillator electrodes with external cable (reference Cahnos F7952W), a replacement consumable compatible with the equipment of the families Physio-Control LIFEPAK, Bexen Cardio REANIBEX, Cardioline ELIFE 700 and Mindray BeneHeart. It is the indicated solution for emergency services, ambulances, hospitals, health centres, companies and any cardio-protected space equipped with these devices.
Thanks to its configuration with external cable (lead-out), the connector remains accessible without opening the sealed envelope: the pair can be left pre-connected to the device and, at the critical moment, you only need to remove the protective cover and place the pads following the anatomical diagrams on the packaging. It is sold per pair (2 units) with immediate dispatch and specialised technical support from Cahnos.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the biphasic transthoracic shock and enables emergency electrocardiogram monitoring. This pair is indicated for adult patients (over 8 years old or over 25 kg) for defibrillation, synchronized cardioversion and ECG monitoring.
The low-impedance conductive adhesive gel ensures homogeneous contact with the skin, low interface resistance and optimal energy transmission; the inner metal foil distributes the current uniformly and the 1 mm medical foam backing adapts to the contours of the chest, minimising the risk of burns. The recommended placement is anterolateral (sternum-apex), according to the diagrams on the packaging. They are single-use and disposable: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the packaging.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | F7952W |
| Product type | Pair of standard multifunction adult defibrillator electrodes with external cable (lead-out) |
| Patient type | Adult (older than 8 years / more than 25 kg) |
| Cable configuration | External cable (lead-out / pre-connected), length 120 cm |
| Total surface (per electrode) | 148 cm² |
| Active surface (per electrode) | 95 cm² |
| Adhesive ring width | 1 cm |
| Supported shocks | Up to 50 shocks (50 to 360 J) |
| Functions | Defibrillation, synchronized cardioversion and ECG monitoring (max. 24 h) |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (1 mm thick) |
| Connection type | Anti-shock safety connector, external cable |
| Use | Single-use, disposable, non-sterile; latex-free and phthalate-free |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10 |
| Shelf life | Approx. 30 months from the date of manufacture; expiry date indicated on the packaging |
| Storage | Dry place, between +5 °C and +35 °C; operating from 0 °C to +50 °C |
| Presentation | Price per pair of electrodes (2 units); 1 pair in heat-sealed polyethylene and aluminium bag (10 pairs per box in adult series) |
Compatibility with defibrillators
| Equipment brand | Compatible models |
|---|---|
| Physio-Control | LIFEPAK 9 (with QUIK-COMBO adapter), LIFEPAK 10, LIFEPAK 12, LIFEPAK 15, LIFEPAK 20, LIFEPAK 20E, LIFEPAK 500 AED (grey socket and pink plug), LIFEPAK 1000 AED, LIFEPAK CR Plus AED, LIFEPAK EXPRESS AED |
| Bexen Cardio | REANIBEX-200, REANIBEX-300, REANIBEX-500, REANIBEX-700, REANIBEX-800 |
| Cardioline | ELIFE 700 |
| Mindray | BENEHEART D1 (Public / Pro), BENEHEART D3, BENEHEART D6 |
Note: compatibility refers to the connector platform of each family. Always verify the correct fit of the connector and cable of your device before clinical use.
4. Equivalences and Cross-References
This electrode (SKU F7952W) is a consumable compatible with the aforementioned defibrillators, not an original spare part certified by each equipment manufacturer: the connector and energy management of each defibrillator are proprietary. After verifying official manufacturer catalogues and regulatory databases (GUDID), the following cross-references with confirmed codes in public sources are identified. Any comparison between brands should be understood as comparable at category level, not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Stryker / Physio-Control | EDGE System Electrodes with QUIK-COMBO Connector & REDI-PAK Preconnect System (original equipment) | 11996-000017 | Comparable by category (not interchangeable 1:1) | Factory original for LIFEPAK 12, 15, 20, 20E, 500 AED and 1000 AED; 42″ (≈107 cm) cable with REDI-PAK pre-connection system; same clinical function (defibrillation, pacing, cardioversion and ECG) and QUIK-COMBO connector. Code confirmed in GUDID/FDA (UDI 00883873784969) and in the official Stryker store. |
| Stryker / Physio-Control | EDGE System Electrodes with QUIK-COMBO Connector (leads-in / no preconnect) | 11996-000091 | Comparable by category (not interchangeable 1:1) | Factory original for LIFEPAK 12, 15 and 20; 24″ (0.6 m) cable inside the packaging (not pre-connected), compared to the 120 cm external cable of this reference. Code confirmed in authorised distribution. |
| Bexen Cardio | Original adult electrodes for Reanibex 200 / 300 / 500 / 700 / 800 (not pre-connected) | TKL0311A | Comparable by category (not interchangeable 1:1) | Factory original replacement for the REANIBEX series; non-pre-connected presentation (internal cable). Code confirmed in authorised distribution. |
| Bexen Cardio | Original adult electrodes for Reanibex 300 (pre-connected) | TKL0313B | Comparable by category (not interchangeable 1:1) | Factory original replacement for REANIBEX-300; pre-connected presentation. Code confirmed in authorised distribution. |
| Mindray | Adult Multifunction Electrode Pads (Basic) for BeneHeart / MR60 series | 115-040517-00 | Comparable by category (not interchangeable 1:1) | Original Mindray for BeneHeart D1, D3, D6 and MR60 series defibrillators; adult >25 kg, up to 50 shocks at 360 J, Mindray proprietary connector and algorithm. Code confirmed in multiple distribution sources (kingpartmedical, dotmed, AliExpress). |
| Cardioline | Single-use defibrillation electrode (2 pcs) for ELIFE 700 | 8730420 | Comparable by category (not interchangeable 1:1) | Original factory replacement for the Cardioline ELIFE 700 defibrillator; supplied in pairs. Code confirmed in authorised distribution. |
No equivalence table validated by the manufacturer exists that authorises the replacement of the original electrodes of these devices with third-party pads: the connector, analysis algorithm and energy management are proprietary to each defibrillator. Any substitution must be validated against the device’s technical data sheet and IFU; consult with the technical department of Cahnos before using in a tender.
5. Selection tips and variants of interest
Confirm the device model: this pair corresponds to Physio-Control LIFEPAK 9 (with QUIK-COMBO adapter), 10, 12, 15, 20, 20E, 500 AED (grey socket and pink connector), 1000, CR Plus and EXPRESS defibrillators, as well as Bexen Cardio REANIBEX, Cardioline ELIFE 700 and Mindray BeneHeart D1/D3/D6. Always check the connector fit and the expiry date printed on the packaging before replacement; do not use an expired electrode or reuse a pair after an intervention.
Choose the variant according to workflow: the external lead-out cable of this model allows the device to be pre-connected and ready in seconds; if you prefer an internal cable, reference F7952 is available (same standard adult series with 120 cm cable). For a 200 cm cable, consider F7952/200. If you need radiolucent electrodes for imaging procedures, F7752W (radiolucent with external cable) or F7752 (radiolucent with internal cable) are available. For paediatric patients with the same devices, use paediatric references F7952P (standard), F7952PW (lead-out) or F7952WPL (limited energy 200 J → 50 J).
Storage and expiry: store in a dry place between +5 °C and +35 °C and observe the expiry date on the packaging; the conductive gel may dry out and reduce conductivity after the expiry date. As this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock (FIFO). For volume orders or tenders, contact the technical department of Cahnos stating the exact model and serial number of your device.