Digital Clinical Audiometer SibelSound 400-Supra (Ref. 33626) – Air and Bone Conduction, Masking, Supraliminal Tests, W50 Software and Intercom Kit

5.605,00 €

Two-channel digital clinical audiometer SibelSound 400-Supra for complete hearing assessment: air conduction (TDH 39), bone conduction (B71), masking, SISI and supraliminal tests (Fowler-ABLB, Tone Decay, Weber, Lüscher), speech audiometry and musical frequencies. Includes W50 software, intercom kit and database of 1,000 tests. USB connection to PC, direct printing and automatic diagnosis (COUNCIL, IMSS, ELI, SAL, Klockhoff, MOH). Class II A medical device. For large orders you can request a quote.

Sales unit: 1 unidad
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM33626

Description

1. Commercial Introduction

The SibelSound 400-Supra digital clinical audiometer (ref. 33626, SKU Cahnos GM33626) is the most complete model in the SibelSound 400 series: a professional audiometry station that combines air conduction, bone conduction, masking, supraliminal tests and speech audiometry, together with the W50 audiometry software and the intercom kit, all included as standard. It is designed for ear, nose and throat (ENT) clinics, audiology services, hearing centres and occupational health units that need a reliable, fast clinical device with computerised management of results.

2. Technical explanation of the equipment

This is a two-channel audiometer based on digital signal processing (DSP), designed for quick and easy exploration of hearing thresholds and for screening tests and supraliminal tonal tests (Fowler-ABLB, Tone Decay, Weber, Lüscher, etc.). The device allows exploration via air conduction with TDH 39 headphones in the range of 125 to 8,000 Hz (or up to 20,000 Hz in high frequency with the optional HDA 200 headphones) and via bone conduction with the B71 vibrator. It incorporates manual or synchronised masking with narrow band noise (NBN), white and speech noise, SISI test, speech audiometry, musical frequencies and automatic calculation of hearing loss with diagnosis according to the COUNCIL, IMSS (Mexico), ELI, SAL, Klockhoff and MOH protocols, among others.

The communication system is one of the model’s strong points: it allows direct printing to a USB printer or connection to the PC via USB cable to the W50 software (included) to view, archive, transmit, analyse and enter audiometric tests. The software also accepts data from other audiometers, displays automatic diagnosis and is compatible with Windows 7, 8.1 and 10 in 32 and 64-bit versions. It also includes an intercom kit (headphones + microphone) with a database of 1,000 tests.

3. Technical Specifications

Characteristic Specification
Audiometry type 2 clinical (two channels, DSP)
Airway TDH 39: 125 – 8,000 Hz
High frequency (optional) HDA 200: 8,000 – 20,000 Hz
Bone conduction B71
Levels Air conduction: -10 to 120 dB HL / Bone conduction: -10 to 70 dB HL / Speech: -10 to 100 dB HL / Free field: -10 to 80 dB HL
Masking (manual or synchronised) NBN air conduction: -10 to 100 dB HL / NBN bone conduction: -10 to 70 dB HL / White and speech: -10 to 100 dB SPL
Tone Continuous, pulsed, alternating, amplitude modulation
Level increments 5 dB (400-A/400-AOM), 1 or 5 dB (Supra)
Accuracy Frequency ±1% / Level ±2% dB SPL
Tests included SISI, supraliminal tests (Fowler-ABLB, Tone Decay, Weber, Lüscher), speech audiometry, musical frequencies
Automatic diagnosis COUNCIL, IMSS (Mexico), ELI, SAL, Klockhoff, MOH and others
Intercom kit Headphones + microphone; database of 1,000 tests
Connectivity USB to PC and USB printer
Software W50 audiometry software (included); compatible with Windows 7, 8.1 and 10 (32/64-bit)
Display Backlit alphanumeric LCD, 2 lines of 16 characters
Dimensions 390 x 260 x 105 mm
Weight 2.4 kg (without accessories)
Power supply 100 – 240 V, 50/60 Hz
User manual GB, IT (FR and ES available on request)

Product data

Brand SIBELSOUND
Manufacturer reference 33626
SKU Cahnos GM33626
Sales unit 1 pc
Device type Medical device
Device class II A
CND Z121401
GMDN 10228
EAN 8436035522026

4. Equivalences and Cross-References

This product corresponds to the manufacturer’s original reference SibelSound / Ref. 33626, which Cahnos markets as GM33626. Within the same SibelSound 400 family, the following variants are available, sharing the same chassis, DSP and communication system, differing in the scope of tests:

Model SKU Cahnos Reference Features W50 software
SibelSound 400-A (screening) GM33623 33623 Air conduction; intercom database of 150 tests Optional
SibelSound 400-AOM (diagnostics) GM33624 33624 Air conduction + bone conduction + masking; database of 1,000 tests Optional
SibelSound 400-Supra (clinical, this product) GM33626 33626 Air conduction + bone conduction + masking + supraliminal tests + SISI + speech audiometry + intercom kit Included

Audiometers from other manufacturers cover comparable performance ranges (e.g., Interacoustics, Amplivox or Otometrics in two-channel clinical devices), but there is no validated 1:1 equivalence table with the SibelSound 400 series; the W50 software is supplied linked to the series and, in its optional version (ref. 33629), corresponds to models marketed up to March 2023. Consult the technical department of Cahnos to confirm compatibilities or specific configurations.

5. Selection tips and variants of interest

Choose the 400-Supra if your centre performs advanced clinical audiometry: supraliminal tests (Fowler-ABLB, Tone Decay, Weber, Lüscher), SISI test, speech audiometry and musical frequencies, with the W50 software and intercom kit already included. For occupational medicine or hearing screenings with air conduction, the 400-A model (GM33623) may be sufficient; for intermediate diagnostic needs with bone conduction and masking, the 400-AOM (GM33624) is the indicated alternative. Remember that the high-frequency headphones HDA 200 are optional and extend the examination up to 20,000 Hz. For large orders you can request a quote: contact the technical-commercial team at Cahnos to receive a no-obligation offer tailored to your project.

Additional information

Manufacturer reference

33626

Audiometry type

2 clinical (two channels, DSP)

Airway

TDH 39: 125 – 8,000 Hz

Bone conduction

B71

High frequency (optional)

HDA 200: 8,000 – 20,000 Hz

Masking

NBN air and bone conduction, white and speech noise (manual or synchronised)

Tests included

SISI, supraliminal tests (Fowler-ABLB, Tone Decay, Weber, Lüscher), speech audiometry, musical frequencies

Automatic diagnosis

COUNCIL, IMSS, ELI, SAL, Klockhoff, MOH

Software

W50 audiometry software (included); Windows 7, 8.1 and 10 (32/64-bit)

Connectivity

USB to PC and USB printer

Intercom kit

Headphones + microphone; database of 1,000 tests

Display

Backlit alphanumeric LCD, 2 lines of 16 characters

Dimensions

390 x 260 x 105 mm

Weight

2.4 kg (without accessories)

Power supply

100-240 V, 50/60 Hz

CND code

Z121401

GMDN code

10228

EAN

8436035522026

Presentacion

Unit

Tipo dispositivo

Medical device

Clase sanitaria

II a

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityMultilingüe PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesMultilingüe PDF

Reviews

There are no reviews yet.

Be the first to review “Digital Clinical Audiometer SibelSound 400-Supra (Ref. 33626) – Air and Bone Conduction, Masking, Supraliminal Tests, W50 Software and Intercom Kit”

Your email address will not be published. Required fields are marked *