Description
1. Introduction
The fetal Doppler ECOsound (Ref. 35.71-2600) is a compact and lightweight pocket monitor that allows you to listen to and visualise the fetal heart rate with total clarity. Its waterproof 2 MHz high-sensitivity catheter, its LCD screen and its ease of use make it an indispensable ally for midwives, obstetricians, nursing staff and primary care physicians, both in the clinic and in emergency departments, home care or births in low-intervention centres. It is delivered ready to use with a carrying bag, ultrasound gel and 2 AA batteries, and comes with a 24-month CE MDD warranty.
2. Technical explanation of the equipment
The device operates using continuous-wave ultrasound Doppler technology: the 2 MHz catheter emits ultrasound waves that, when reflected by the movement of fetal cardiac structures, generate an audible signal and a numerical reading of the fetal heart rate (FHR). The LCD screen displays the heart rate and battery status, while the integrated noise reduction optimises signal quality for reliable detection even in conditions of poor accessibility to the fetal focus. The waterproof catheter facilitates cleaning and disinfection between patients and allows its use in humid environments. The device achieves clinical sensitivity from week 10 of gestation, with a measurement range of 50 to 240 beats per minute and an accuracy of ±2 %. Due to its 2 MHz (low frequency) catheter, it offers greater penetration and is especially recommended in patients with a high body mass index (BMI).
3. Technical Specifications
| Model | ECOsound (official factory construction; reference 35.71-2600 matches the original manufacturer’s product number, verified on its website and official technical data sheet) |
| Reference | 35.71-2600 |
| Display | LCD with heart rate display and battery indicator |
| Catheter | Fixed 2 MHz ultrasound catheter, waterproof, high sensitivity |
| Measurement range | 50 – 240 bpm (beats per minute) |
| Accuracy | ±2 % |
| Ultrasound intensity | <10 mW/cm² |
| Sensitivity | From week 10 of gestation |
| Speaker | Integrated 1.2 W with adjustable volume control |
| Audio output | Headphone jack |
| Auto power-off | Yes, after 5 minutes of inactivity |
| Battery life | Approx. 6 hours of continuous measurement |
| Power supply | 2 AA batteries of 1.5 V |
| Contents | Unit, carrying bag, ultrasound gel and 2 AA batteries |
| Clinical indication | Detection and monitoring of fetal heartbeat; examination of pulses and blood flow |
| Classification | Medical device with CE marking (MDD); 24-month warranty |
4. Equivalences and Cross-References
Notice about the code: the reference 35.71-2600 used by Cahnos is the official product number of the original ECOsound manufacturer (verified on the manufacturer’s website and technical data sheet), so it can be indicated as is in orders, tenders and competitions that require the original reference.
There is no official cross-reference equivalence table published by the manufacturer for this reference; the following cross-references have been verified against the manufacturer’s own sources (catalogue, IFU or GUDID/FDA database) and are classified as comparable by category, not interchangeable 1:1. Before any substitution, checks must be made field by field: frequency and type of catheter, presence of FHR display, waterproofing, included accessories and regulatory classification.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Huntleigh Healthcare | Sonicaid FD1 (fetal Doppler with frequency display) | FD1 | Comparable by category (not interchangeable 1:1) | Fixed waterproof 2 MHz catheter and fetal heart rate display; verified in the manufacturer’s catalogue and IFU. Similar presentation and standard accessories (bag, gel and AA batteries). |
| Huntleigh Healthcare | Sonicaid D920 (audio-only fetal Doppler) | D920 | Comparable by category (not interchangeable 1:1) | Same waterproof 2 MHz catheter and same indication for fetal heartbeat detection, but without LCD heart rate display: audio output only. |
| Ultrasound Technologies (UltraTec) | UltraTec PD1dwr (pocket Doppler with FHR display and sealed catheter) | PD1dwr | Comparable by category (not interchangeable 1:1) | Pocket 2 MHz fetal Doppler with sealed catheter for immersion (water birth) and FHR display; different manufacturer and different catheter finish. |
| AB Medica Group (fetatrack) | fetatrack DD250 (fetal and vascular Doppler) | DD250 | Comparable by category (not interchangeable 1:1) | Continuous wave 2 MHz with LCD and range of 50–210 bpm; adds vascular function with optional 3/5/8 MHz catheters and mains or rechargeable battery power. |
There is no manufacturer-validated equivalence table cross-referencing this reference with other brands; consult the Cahnos technical department before using these references as equivalence in tender documents or bids.
5. Selection tips and variants of interest
Who is it for? The ECOsound is the ideal choice for obstetrics and gynaecology clinics, primary care, emergency departments and midwifery training where a pocket Doppler with visual FHR reading, waterproof catheter and maximum portability is needed at a contained cost.
Catheter selection: the 2 MHz catheter offers greater penetration and is recommended in patients with high BMI; if your centre mainly attends early pregnancies, consider alternatives with a 3 MHz catheter, which has shorter penetration. In this data sheet, the catheter is fixed at 2 MHz.
Variants of interest in our catalogue: the IMAMI series Doppler monitors with Bluetooth connection and mobile app (Ref. IMAMI10, IMAMI20 and IMAMI40, with 2.5 MHz transducer) add recording, trends and reports for home and clinic follow-up. If the need is exclusively vascular, the Hi-Dop Doppler (Ref. 40.70-2200) incorporates three 4, 5 and 8 MHz probes with LCD screen for ankle-brachial index and arterial screening. For complete bedside cardiotocographic monitoring, it offers the Smart 1 fetal monitors (Ref. 35.11-7000) and the EcoTwin series (Ref. 35.71-3480 / 35.71-3490).
Consumables and spare parts: always use specific ultrasound transmission gel and replace with quality AA batteries; the carrying bag and headphones can be ordered as replacement accessories. For volume conditions or technical validation in tenders, contact our technical-commercial team.