Li-Ion Battery 25.2V 4.4Ah for Medtronic/Covidien Legendair Airox and Puritan Bennett 560 (PB560) Ventilator | Compatible Spare Part Ref. 2969300 | Code 88888745

392,00 €

Rechargeable lithium-ion (Li-Ion) battery, 25.2 V and 4.4 Ah for the Medtronic/Covidien Legendair Airox and Puritan Bennett 560 (PB560) ventilators. Compatible spare part that reproduces the factory reference 2969300 / PT00053438: direct installation in the equipment compartment, without tools, and sufficient battery life to maintain mechanical ventilation during intra-hospital transfers, patient transport or mains power failures. High energy density Li-Ion chemistry, virtually no memory effect and weight of 0.800 kg. Reliable and economical solution for medical electronics services, ICUs, emergency departments and ventilator fleets. Price per unit, with warranty and technical advice for institutional purchases.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888745

Description

1. Reliable backup power for your Medtronic/Covidien ventilator

Keep your Medtronic/Covidien Legendair Airox ventilator (and the Puritan Bennett 560 / PB560, which share the same pack format) always operational with this rechargeable lithium-ion battery, reference Cahnos 88888745. With 25.2 V and 4.4 Ah, this battery ensures that patient ventilation —controlled, assisted or support mode— is not interrupted during transfers, ambulance transport or a power outage.

It is the replacement that medical electronics, maintenance and hospital purchasing departments need to keep in stock to restore the ventilator’s original autonomy in minutes and without tools, at a significantly lower cost than the official factory spare part, and with the technical and commercial backing of Cahnos for institutional purchases and tenders.

2. How this battery works in the ventilator

The portable ventilators of the Airox Legendair / Puritan Bennett 560 platform operate powered by the mains or, in portable mode, by their internal rechargeable battery. While the equipment remains plugged in, the battery is kept in automatic charging mode; when it is disconnected, moved or in the event of a power cut, the battery takes over the power supply to the turbine, control electronics and alarm system without interrupting patient ventilation.

Lithium-ion (Li-Ion) chemistry offers high energy density, stable 25.2 V voltage, virtually no memory effect and a long service life if the maintenance guidelines indicated at the end of this technical data sheet are followed. A degraded pack manifests itself with loss of autonomy, premature low-battery warnings or the inability to reset the battery alarm; preventive replacement with this reference restores the equipment’s original performance. Installation is direct: the battery sits in its compartment and is recharged by the ventilator’s own integrated electronics.

3. Technical Specifications

Data cross-checked against the internal Cahnos register, the distribution technical data sheet and the service documentation for the 2969300 family of the ventilator:

Parameter Detail
Reference Cahnos (SKU) 88888745
Type / technology Compatible battery (replacement), Li-Ion (lithium-ion), rechargeable
Nominal voltage 25.2 V
Capacity 4.4 Ah (4400 mAh) — ≈ 110.9 Wh
Weight 0.800 kg
Compatibility Medtronic/Covidien Legendair Airox and Puritan Bennett 560 (PB560) ventilators; reproduces factory reference 2969300 / PT00053438
Installation Direct replacement in the ventilator’s battery compartment, without tools or adapters
Recharge Automatic, via the ventilator’s integrated charging electronics when connected to the mains
Application Mechanical ventilation and respiratory support in ICU, emergency departments, medical transport and prehospital care
Maintenance Maintenance-free; periodic inspection in medical electronics programmes
Presentation 1 unit
Recycling Management in accordance with WEEE regulations; do not dispose of as municipal waste

Note: the dimensions of the packs in the 2969300 family are documented in the market as approximately 213.5 × 71.0 × 33.9 mm (common use, not official specification); always check against the removed part and the ventilator housing before replacement.

4. Equivalences and Cross-References

The factory reference for the 25.2 V Li-Ion pack of the Airox Legendair / Puritan Bennett 560 platform is 2969300, also designated in service documentation as PT00053438 Rev A, with associated variants 71CR19/66-2 and 2982400 (Accutronics assemblies). Medtronic/Covidien does not publish an official equivalence table authorising third-party batteries; the listed alternatives share chemistry (Li-Ion) and voltage (25.2 V), but come from another manufacturer and are classified as comparable by category, not 1:1 interchangeable.

Manufacturer / Brand Family / Model Reference Code / SKU Equivalence Level Technical Differences / Remarks
Medtronic / Covidien (equipment manufacturer) Factory battery for Legendair Airox / Puritan Bennett 560 (PB560) 2969300 = PT00053438 Rev A (associated designations: 71CR19/66-2, 2982400) Exact reference equivalence (same manufacturer) OEM designations of the same 25.2 V Li-Ion battery that this reference reproduces as compatible; 4.4 Ah / 4400 mAh according to specialised distribution (Euro Energy) and service documentation. Always verify the marking on the removed cell.
Cameron Sino (Medical) Replacement battery for Airox Legendair / Puritan Bennett 560 / PB560 CS-CDN560MD (EAN 4894128204091) Comparable by category (not interchangeable 1:1) Li-Ion 25.2 V / 4800 mAh (120.96 Wh), blue, dimensions 213.5 × 71.0 × 33.9 mm, net weight approx. 805 g. Spare parts manufacturer different from the original; replaces 2969300 / PT00053438 Rev A / 71CR19/66-2 / 2982400 (battery manufacturer’s catalogue). Higher nominal capacity; check connector and housing.
Kingsener (aftermarket replacement) Battery for Covidien Puritan Bennett 560 / PB560 / Airox Legendair Kingsener 2982400 (25.2 V / 4.8 Ah) Comparable by category (not interchangeable 1:1) Li-Ion 25.2 V / 4.8 Ah, black; spare parts manufacturer different from the original. Replaces PT00053438 Rev A, 71CR19/66-2, TMI 8.0 and Accutronics assemblies 2969300 / 2982400 (battery manufacturer’s catalogue). Higher nominal capacity; confirm that the charging electronics supports the capacity before replacing.

There is no equivalence table validated by the manufacturer (Medtronic/Covidien) that cross-references part number 2969300 with third-party batteries; consult the technical department before using in a tender. Before accepting any alternative, the following must be verified one by one: voltage (25.2 V), chemistry (Li-Ion), connector and pack interface, and housing dimensions, always comparing them with the cell installed in the ventilator.

5. Selection tips and variants of interest

Confirm the exact model and reference: this 25.2 V battery corresponds to the Legendair Airox and Puritan Bennett 560 / PB560 ventilators, which share the pack format. Check the reference printed on the removed battery (2969300, PT00053438, 71CR19/66-2 or 2982400) and the equipment model on its nameplate before ordering.

Do not confuse Medtronic/Covidien families: the Puritan Bennett 840 range uses a different battery (lead 24 V / 7 Ah) and other equipment from the manufacturer uses proprietary formats; only the Airox Legendair and PB560 models use this 25.2 V Li-Ion pack. An incorrect replacement can damage the device’s charging system.

Replace upon signs of wear: clearly reduced battery life, low-battery warnings within a few hours of charging, or a battery alarm that does not reset indicate the end of the accumulator’s useful life. After installation, connect the ventilator to the mains and allow a full charge cycle to complete before a prolonged session in portable mode.

Maintenance and storage: if the equipment is to remain unused for several weeks, keep the battery charged in a cool, dry place and recharge it periodically to prevent degradation of the Li-Ion chemistry; avoid repeated deep discharges.

Recycling: deliver the exhausted pack to a collection point in accordance with WEEE regulations; never place it in the general waste container. For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department stating the model, serial number and reference of the fitted battery; we will confirm compatibility and offer special terms for volume.

Additional information

Technology

Li-Ion (lithium-ion), rechargeable

Nominal voltage

25.2 V

Capacity

4.4 Ah (4,400 mAh)

Energy

≈ 110.9 Wh

Weight

0.800 kg

Compatibility

Medtronic/Covidien Legendair Airox; Puritan Bennett 560 (PB560); reproduces factory reference 2969300 / PT00053438

Manufacturer reference

2969300, PT00053438 Rev A, 2982400, 71CR19/66-2

Installation

Direct replacement in the ventilator compartment, without tools

Recycling

Compliant with WEEE regulations

Product type

Compatible battery (replacement)

Recharge

Automatic, via the ventilator's integrated charging electronics

Application

Mechanical ventilation in ICU, emergency departments, medical transport and prehospital care

Presentacion

Unit

Reviews