Description
1. Precision energy from Duracell for your medical equipment
Silver oxide button cells are the reference energy source for low-consumption medical devices that require stable voltage throughout their service life. This Duracell 392/384 battery (management reference 0385038) guarantees reliable operation of glucometers, digital thermometers, wrist blood pressure monitors, clinical watches and other small equipment that work with SR41 format. It is presented in a pack of 2 blisters of 1 battery each (2 batteries), designed so that clinics, surgeries and home care services always have a certified replacement with fast delivery.
2. Technical Explanation
The Duracell 392/384 battery is a primary (non-rechargeable) silver oxide (Ag2O-Zn) button cell with a nominal voltage of 1.55 V and potassium hydroxide electrolyte in the high-discharge variant (SR41W). Its IEC designation is SR41 and it corresponds to the commercial denominations 392 and 384, which refer to the same cell of Ø 7.9 × 3.6 mm and coexist on the product labelling: the pack covers both codes, common in equipment manufacturers’ manuals. Silver oxide technology offers a virtually flat discharge curve until depletion, high energy density per unit volume and excellent leakage resistance thanks to the case sealing, critical requirements in medical electronics where a premature voltage drop can alter measurements. It contains no added mercury and complies with the requirements of standard IEC 60086.
3. Technical Specifications
| Characteristic | Detail |
| Brand | Duracell |
| Battery type | Silver oxide button cell (Ag2O-Zn), primary |
| IEC designation | SR41 (SR41W) |
| Compatibility | 392 and 384 batteries |
| Nominal voltage | 1.55 V |
| Approximate capacity | ≈ 45 mAh |
| Dimensions | Ø 7.9 × 3.6 mm |
| Manufacturer reference (official construction) | D392/384 (IEC SR41) |
| Management / distributor reference | 0385038 |
| SKU | 385038 |
| Presentation | 2 blisters of 1 battery each |
| Sales unit | Pack of 2 batteries |
| Rechargeable | No (single-use primary battery) |
| Main use | Glucometers, digital thermometers, wrist blood pressure monitors, clinical watches and low-consumption medical equipment |
4. Equivalences and Cross-References
Note on the code: reference 0385038 is the distributor’s management code. The official Duracell construction nomenclature for this cell is D392/384 (IEC designation SR41), and it should be requested in orders and tenders that require the factory code; the cell simultaneously covers the commercial denominations 392 and 384. The SR41 format is an IEC standard, so this battery is dimensionally and electrically comparable with other silver oxide cells of 1.55 V from other manufacturers, verified by chemistry, voltage and dimensions:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Maxell | SR41W (392) | SR41W / 392 (ref. Cahnos 0018008, blister of 10) | Comparable by category (not interchangeable 1:1) | Same silver oxide chemistry, 1.55 V and dimensions Ø 7.9 × 3.6 mm; declared capacity ≈ 39 mAh vs. ≈ 45 mAh of Duracell. Presentation in blister of 10 units. |
| Varta | V392 (also V547) | V392 / V547 | Comparable by category (not interchangeable 1:1) | SR41 cell of 1.55 V with KOH electrolyte (high discharge); same geometry Ø 7.9 × 3.6 mm and stable voltage curve for watchmaking and precision instruments. |
| Energizer | 392 (SR41W) | 392 (Eveready 392) | Comparable by category (not interchangeable 1:1) | Silver oxide 1.55 V in SR41 format; same cell dimensions and commercial equivalents 392/384. Verify capacity of the received lot. |
| Renata | 392 (SR41) | 392 (blister of 1 unit) | Comparable by category (not interchangeable 1:1) | Swiss silver oxide cell 1.55 V, Ø 7.9 × 3.6 mm; commonly used in watchmaking and low-consumption precision medical electronics. |
There is no equivalency table validated by the manufacturer that cross-references this part with third parties; the cross-references indicated have been verified against technical catalogues and sector cross-reference tables, but 1:1 substitution must be validated field by field (chemistry, voltage, capacity and dimensions) before use in tenders. Consult with the technical department before use in tenders.
5. Selection tips and variants of interest
Before replacing the battery in your equipment, confirm the code printed on the compartment or in the manual: 392 or 384 (SR41) indicate this cell of Ø 7.9 × 3.6 mm; if the device indicates LR41/AG3, it is the alkaline variant of 1.5 V, which is not 1:1 interchangeable with the silver oxide one due to its discharge curve. For medical measurement devices (blood glucose, temperature, blood pressure), silver oxide chemistry is the appropriate option due to its constant voltage until the end of service life. Usage recommendations: do not mix new batteries with depleted ones or different chemistries in the same equipment, respect the polarity (+/−) marked in the compartment and replace both cells at the same time in equipment that uses two units. Keep spare batteries in a cool, dry place (15–25 °C) and dispose of depleted batteries as waste according to the regulations on batteries and accumulators (Royal Decree 106/2008). In our catalogue you also have other medical button cells: the Duracell 389/390 (ref. 0385037 / SKU 385037, SR54 cell of Ø 11.6 mm) and the Maxell SR41 392 (ref. 0018008) as a functional alternative of the same category. For institutional orders or tenders, contact our technical-commercial department to confirm the official reference and the formalised budget.





Reviews
There are no reviews yet.