Description
1. Reliable power for your Laerdal LSU suction unit
At Cahnos we offer you the original Laerdal LSU rechargeable battery (MFR 780800, Ref. 88888966), the power replacement indicated to restore full operability to the Laerdal Suction Unit (LSU) mucus suction unit, one of the reference portable suction devices in healthcare. It reproduces the performance of the original pack so that your device recovers its full autonomy without having to change the device.
It is a rechargeable spare part, with direct installation and maintenance-free, designed for emergency services, out-of-hospital emergencies, ambulances, hospital wards and medical electronics programmes. The reference 780800 is the manufacturer’s official numbering, confirmed on the Laerdal website as ‘LSU NiMH Battery’ for the LSU suction unit.
2. How this battery works
The Laerdal LSU suction unit is an autonomous suction device that generates the necessary vacuum to clear the airway by extracting mucus, blood and secretions through the catheter and suction tube, with collection in the collection jar. When no mains power is available, the device is powered by this internal nickel-metal hydride (Ni-MH) battery of 12 V, which supplies stable voltage and power to the vacuum motor during patient transport and in environments without a power outlet.
Ni-MH chemistry offers a stable discharge curve and supports repeated recharge cycles without the memory effects of older Ni-Cd cells, making it the appropriate choice for intermittent and intensive clinical use. The battery is recharged using the integrated charger of the suction unit itself, and the unit is delivered ready to install, with the same housing and contact as the factory part.
3. Technical Specifications
Pack data cross-checked against the Laerdal manufacturer’s data sheet, authorised distribution documentation and the European market for medical equipment spare parts.
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | 88888966 |
| Manufacturer reference (MFR) | 780800 (Laerdal, ‘LSU NiMH Battery’) |
| Battery type | Ni-MH (nickel-metal hydride), rechargeable, sealed |
| Nominal voltage | 12 V DC |
| Nominal capacity | 2.2 Ah (2200 mAh) |
| Approximate energy | ≈ 26.4 Wh |
| Approximate dimensions | 19 × 7 × 3 cm (190 × 70 × 30 mm) according to Laerdal data sheet; pack documented by European assembler: 182 × 23 × 61 mm |
| Approximate weight | ≈ 0.37 kg |
| Rechargeable | Yes, with the integrated charger of the LSU suction unit |
| Battery life | Up to 5 hours of operation on a full charge (according to the pack distribution data sheet) |
| Compatible equipment | Mucus suction units Laerdal Suction Unit (LSU); equipment units 780400 and 78002001. Verify compartment and connector |
| Installation | Directly in the battery compartment, without tools |
| Use | Suction of mucus and secretions in emergency departments, patient transport and home care |
| Presentation | 1 unit |
| Recycling | RAEE/WEEE |
4. Equivalences and Cross-References
The reference 780800 is Laerdal’s original numbering for this battery, confirmed on the manufacturer’s official website for the LSU suction unit. There is no equivalence table validated by Laerdal that authorises third-party batteries; the references listed below come from manufacturers and distributors specialised in biomedical batteries and are classified as comparable by category, not interchangeable 1:1. Before accepting an alternative battery, each of the following must be verified one by one: voltage (12 V), capacity, chemistry (Ni-MH), compartment dimensions and connector type.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Laerdal (original equipment battery) | LSU NiMH Battery for Laerdal Suction Unit | 780800 | Exact reference equivalence (same manufacturer) | Original part from the equipment manufacturer: rechargeable Ni-MH 12 V pack with factory housing and contact; this is the part that this spare reproduces. Verify batch before replacement. |
| Unipower (OSI Batteries) | Medical Replacement Battery for Laerdal Suction Unit | B12315 | Comparable by category (not interchangeable 1:1) | Rechargeable Ni-MH 12 V / 2.0 Ah pack documented as a replacement for the Laerdal 780800 in the spare manufacturer’s data sheet (OSI Batteries); slightly lower capacity (2.0 vs 2.2 Ah). Verify connector and compartment dimensions. |
There is no equivalence table validated by the manufacturer (Laerdal) cross-referencing this part with third parties; consult the technical department before use in tenders. As a control reference, the same Ni-MH 12 V / 2.2 Ah pack format for the LSU is documented by the European assembler with origin 780800 and suitability for unit 780400. Do not confuse this battery with the one for the Laerdal LCSU 4 suction unit (MFR 886113, Ref. 88888923): although both are 12 V Ni-MH packs, they belong to different equipment families and an incorrect replacement can damage the device’s charging system.
5. Selection tips and variants of interest
- Check the exact model of your equipment: this battery is the one indicated for the Laerdal Suction Unit (LSU). Check the reference printed on the original battery: if it matches 780800, this spare part is the direct replacement.
- Do not confuse it with other variants of the same brand: the battery for the Laerdal LCSU 4 suction unit (MFR 886113, Ref. 88888923) belongs to another equipment family with a different format, although it shares chemistry and voltage.
- Purchase planning: rechargeable batteries are consumables that wear with use; it is recommended to have at least one spare unit per device for preventive maintenance and to avoid downtime during shifts and emergency care.
- Maintenance: if the unit is to remain unused for a long time, keep it with the battery charged and perform a periodic recharge (every 2-3 months) to avoid deep discharge. Excessive heat shortens the life of the cells.
- Environmental management: take the exhausted battery to a specialised collection point (RAEE/WEEE); do not place it in the general waste container.
- Variants of the same range at Cahnos: rechargeable packs for other portable suction units, such as the Laerdal LCSU 4 (88888923), Medela Vario (88888865), Asskea DC30 (88888039), Weinmann Accuvac Rescue (88888639) or Asskea M30W (88888804). They are not interchangeable with this reference without technical verification.
For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department to confirm compatibility with your equipment fleet, delivery times and a formalised quotation.