Description
1. Reliable backup power for your haemodialysis generator
At Cahnos we make available to you the 24 V and 7 Ah battery (NP7-12 format) for the dialysis generator FRESENIUS 5008 / 5008H, the replacement that reproduces the original part M402651 and restores the haemodialysis monitor to its full standard autonomy. Designed for nephrology services, hospital dialysis units and outpatient dialysis centres, it ensures continuity of treatment even in the event of power cuts, voltage drops or movement of the equipment between rooms.
It is the ideal solution for institutional purchases, medical electronics services and preventive maintenance of generator fleets: a traceable replacement, with the same electrical performance as the original battery and a very contained cost compared to the equipment manufacturer’s part.
2. How this battery works in the 5008 / 5008H generator
The FRESENIUS haemodialysis generators of the 5008 / 5008H series incorporate an internal rechargeable battery that acts as a backup power source: while the equipment remains connected to the mains, the system keeps the accumulator charged and automatically switches to battery operation when the supply is interrupted. In this way, the control electronics, infusion pumps, valves and the monitor’s alarm system remain operational during the dialysis session without loss of service.
The pack consists of two sealed lead-acid (VRLA) cells of 12 V / 7 Ah connected in series, which add up to the nominal 24 V in the standardised NP7-12 format. Sealed lead-acid chemistry is the right choice for this application: it delivers a very stable discharge voltage, withstands frequent charge and discharge cycles with the generator’s own charger and requires no maintenance. When the autonomy is noticeably reduced or the equipment warns of low battery after recent charging, it is time to replace the accumulator with this reference.
3. Technical Specifications
| Reference Cahnos (SKU) | 88888840 |
| Original equipment reference | M402651 (FRESENIUS) |
| Battery type | Sealed lead-acid (VRLA), rechargeable |
| Nominal voltage | 24 V (2 × 12 V in series) |
| Capacity | 7 Ah (NP7-12 format; replacement technical data sheet: 7.2 Ah) |
| Nominal energy | ≈ 168 Wh (24 V × 7 Ah) |
| Compatibility | FRESENIUS 5008 / 5008H dialysis generator |
| Durability | Long service life and consistent performance in medical applications |
| Approximate dimensions | 151 × 65 × 200 mm (according to the distribution replacement data sheet) |
| Approximate weight | ≈ 4.08 kg (according to distribution data sheet; ≈ 5 kg in alternative replacements) |
| Cell format | NP7-12 (2 cells of 12 V / 7 Ah in series) |
| Rechargeable | Yes; integrated charging in the generator when connected to the mains |
| Installation | Directly in the equipment compartment, without tools |
| Presentation | 1 unit |
| Recycling | Dispose of in accordance with WEEE regulations |
Note: the voltage, capacity and chemistry correspond to the pack documented for the 5008 / 5008H generators. As this is a replacement, it is recommended to compare dimensions, connector and cell configuration with the original battery before replacement.
4. Equivalences and Cross-References
The original battery reference for the FRESENIUS 5008 / 5008H generators is the part M402651, consistently documented in specialised European distribution (VLAD/Exalium Premium, ASELUX, Alliance Médical) as the source code that this replacement reproduces. There is no official equivalence table published by the equipment manufacturer authorising third-party batteries; the following alternatives have been checked against data sheets from manufacturers and replacement distributors and are classified as comparable by category, not interchangeable 1:1:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| FRESENIUS (original equipment battery) | Battery pack for the 5008 / 5008H generator | M402651 | Exact reference equivalence (original part from the equipment manufacturer) | 24 V lead battery that this replacement reproduces; consistently confirmed in specialised European distribution. Always verify the label and batch of the removed pack before replacing. |
| XCell (Akkushop-Schweiz / Greenweez distribution) | Lead battery compatible with the Fresenius Vial 5008 dialysis system | 1ACCU0110 | Comparable by category (not interchangeable 1:1) | 24 V / 7.2 Ah, ≈ 151 × 65 × 200 mm and ≈ 5 kg, supplied without cable or plug; same electrical platform (24 V / 7.2 Ah) and equivalent dimensions; verify connector and wiring before mounting. |
| NX / Upergy (All-batteries.fr) | Rechargeable medical battery for FRESENIUS 5008 | MXP0027 (MXP0027-1) | Comparable by category (not interchangeable 1:1) | AGM lead 24 V / 7 Ah, dimensions 153 × 70 × 205 mm; manufactured in a certified workshop ISO 9001 / ISO 13485. Capacity and chemistry matching with slightly larger dimensions; check the compartment and connector of the generator. |
There is no equivalence table validated by the equipment manufacturer (FRESENIUS Medical Care) authorising third-party batteries for the 5008 / 5008H generators; consult the technical department before using in a tender. Before any replacement, check field by field: voltage (24 V), capacity (7–7.2 Ah), chemistry (sealed lead-acid), format NP7-12 (2 × 12 V in series), dimensions and connector type.
5. Selection tips and variants of interest
- Identify the exact model: confirm that your unit is a FRESENIUS 5008 or 5008H generator and note down the reference marked on the exhausted battery (M402651 or another) before ordering the replacement.
- Do not confuse it with the 6008 format: the documented variant for the 6008 / 5008H generator (distribution ref. 88890544) has different dimensions (305 × 65 × 107 mm); each platform accepts a specific pack and they are not interchangeable without technical validation.
- Replace when signs of wear appear: noticeably reduced autonomy, premature low-battery warnings or excessive recharging times indicate the end of the accumulator’s useful life; in continuous clinical use, preventive renewal is recommended every 2-3 years.
- Lead-acid battery maintenance: if the generator is to remain unused for long periods, carry out a periodic recharge (every 2-3 months) and avoid deep discharges so as not to shorten the life of the cells.
- Environmental management: take the exhausted battery to an authorised collection point in accordance with the RAEE / WEEE regulations; do not place it in the general waste container.
- Institutional orders: for tenders, continuous supply contracts or large volumes, contact our technical-commercial department to confirm compatibility with your batch of generators, lead times and formalised budget.