Description
1. Replacement battery for your Liko Golvo 8008 lift
At Cahnos we offer you the replacement battery for the Liko Hill-Rom Golvo 8008 patient lift system (also indexed as Galvo 8008), one of the most widely installed mobile transfer hoists in hospitals, care homes and social healthcare centres. It is a rechargeable pack with Ni-MH technology (nickel-metal hydride) with a nominal voltage of 24V and a capacity of 2.7Ah, designed to restore the lift’s full autonomy: stable, safe and uninterrupted lifting operations during daily patient care.
It is the ideal solution for medical electronics maintenance services and for purchasing departments looking for a reliable spare part with an excellent price-performance ratio compared to the original part, without compromising the electrical performance required by the equipment.
2. How this battery works in the patient lift
The Liko Golvo 8008 is a mobile patient lift (transfer hoist) that incorporates an electrical power supply system with a rechargeable battery to operate the lifting actuator. When the equipment is not connected to the mains charger, the battery takes over the power supply for the control electronics and the motor, allowing bed-to-chair transfers, in-bed positioning or general mobilisation with full continuity of care.
Ni-MH chemistry is the right choice for this application: it offers a good capacity-to-weight ratio, supports frequent charge and discharge cycles and exhibits less memory effect than older Ni-Cd cells, so it maintains its autonomy with simple maintenance. The battery is recharged with the lift’s own charger while the equipment remains connected to the mains. When the autonomy is noticeably reduced or the equipment warns of a low battery, it is time to replace it to ensure safety and continuity of service.
3. Technical Specifications
Technical data recorded in the product data sheet:
| Parameter | Specification |
|---|---|
| Application | Patient lift system Liko Hill-Rom Golvo 8008 (Galvo 8008); Golvo 8000 / Viking M family |
| Original reference | 2006107 (associated designations: BAL 20001-02, CSA07033) |
| Technology | Ni-MH (nickel-metal hydride), rechargeable |
| Nominal voltage | 24V |
| Capacity | 2.7Ah |
| Energy | 64.8Wh |
| Weight | Approximately 1.5 kg |
| Dimensions | 105 x 85 x 55 mm |
| Recharge | Yes; with the lift charger (connected to mains) |
| Presentation | 1 unit |
| Device manufacturer | Liko Hill-Rom (original) |
Verification note: the voltage, capacity and energy values correspond to the BAL 20001 family pack documented for the Golvo 8000/8008 lifts. Exact dimensions may vary depending on the pack version; always compare the reference printed on the label of the removed battery, the 24V voltage and the lift housing before fitting.
4. Equivalences and Cross-References
Verification note: there is no official cross-reference equivalence table published by the manufacturer (Hill-Rom/Liko) linking this reference to third-party spare parts. References 2006107, BAL 20001-02 and CSA07033 are OEM designations of the same original pack (Liko / Linak platform). The third-party alternatives listed below have been checked one by one against data sheets from biomedical battery manufacturers and specialised technical distribution; they share Ni-MH technology and 24V voltage, but 1:1 replacement must be validated field by field (connector, polarity and housing) before fitting.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| OSI Batteries (Unipower) | Biomedical series for Liko Golvo 8000 / 8008 lifts | B11957 | Comparable by category (not interchangeable 1:1) | Biomedical replacement Ni-MH 24V / 2.7Ah that replaces BAL 20001-02 and 2006107 for Golvo 8000/8008; confirmed in the official OSI Batteries data sheet. Verify connector and housing. |
| R&D Batteries | Spare part for Liko Golvo 8000 / 8008 (BAL20001-02, 2006107) | 6501-1 | Comparable by category (not interchangeable 1:1) | Ni-MH 24V / 2.7Ah documented in the official data sheet for Golvo 8000 and 8008; cross-referenced with NCE N1451-OEM. Verify geometry, connector and dimensions before fitting. |
| Master Instruments (MI Battery Experts) | Medical battery for patient lift Linak BAL 20001-01 / 02 | MB514M | Comparable by category (not interchangeable 1:1) | Ni-MH 24V / 2.7Ah (64.8Wh) for the BAL 20001-01/02 variants, confirmed in the manufacturer’s official data sheet (178 x 32 x 50 mm). Check connector and fit in the original compartment. |
| Cameron Sino | Biomedical series for Liko Viking M / Golvo 8008 | CS-HRM107MD | Comparable by category (not interchangeable 1:1) | Ni-MH 24V / 2500mAh (60Wh) that replaces BAL 20001-02, 2006107 and CSA07033; capacity lower than the original pack (2.5Ah vs 2.7Ah). Verify connector and dimensions (176 x 51.8 x 31.75 mm). |
| Partopia Medical | Biomedical spare part for Liko Golvo 8000 / 8008 lifts | PM1099 | Comparable by category (not interchangeable 1:1) | Ni-MH 24V / 2.7Ah documented in a technical distributor data sheet as an OEM replacement BAL 20001-02 / 2006107. Verify connector, polarity and housing. |
There is no equivalence table validated by the manufacturer (Hill-Rom/Liko) that cross-references this reference with third-party spare parts; consult the technical department before use in tendering. Before any replacement, the following must be verified one by one: voltage (24V), capacity (2.7Ah), technology (Ni-MH), connector type and dimensions of the lift compartment.
5. Selection tips and variants of interest
Identify the correct battery: confirm on the label of the removed pack whether it shows 2006107, BAL 20001-02 or CSA07033; all are designations of the same 24V battery. Do not mount batteries of a different voltage or chemistry without validation from the technical service.
Check the connector and compartment: measure the battery housing and check the connector orientation and wiring slack before mounting. Packs in this family may have slight case variations depending on the manufacturer and connector termination (-01, -02, -4PTS).
Ni-MH maintenance: if the lift remains unused, recharge the battery periodically (approximately every 6-8 weeks) to prevent deep discharges that shorten its service life. After replacement, leave the lift connected to the charger to complete charging and perform a lift test before returning it to clinical service.
Variants of the same family at Cahnos: for other Liko/Hill-Rom lifts we have packs from the BAL 20001 family with a 4-pin connector (Ref. 88888759), the Viking 4-Point Connector battery (Ref. 88888857) and the Likorall 242S ceiling hoist battery (Ref. 88888792). Do not interchange these references between models without verifying voltage and connector.
Environmental management: at the end of its service life, deliver the used battery to an authorised collection point (WEEE); do not dispose of it in the general waste container. For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm exact compatibility with your lift and obtain a formal quote.





Reviews
There are no reviews yet.