Description
1. Compact Duracell energy for your medical equipment
The button cell Duracell LR44 (ref. 0385019) is the reference replacement for keeping clinical thermometers, pocket oximeters, finger pulse oximeters, digital blood pressure monitors, portable measuring devices, calculators, remote controls and low-consumption electronics in the healthcare environment operational. With the guarantee of one of the most recognised brands in the sector, this cell ensures a stable and durable energy supply, with a sealed, leak-resistant construction that protects the equipment and prevents unexpected downtime in clinics, medical electronics services and home care. It is presented in a blister of 2 units, the ideal format for quick replacement and preventive maintenance, so that the clinic always has an original, certified replacement with fast delivery.
2. Technical Explanation
The Duracell LR44 is a primary non-rechargeable battery of alkaline electrochemical system of manganese dioxide and zinc (Zn-MnO₂), with a nominal voltage of 1.5 V. Its format corresponds to the IEC designation LR44 (ANSI/NEDA 1166A), also known as 76A in the Duracell factory nomenclature, with standardised dimensions of Ø 11.6 × 5.4 mm that guarantee dimensional interchangeability with any compartment designed for this type of button cell.
Alkaline technology offers a stable discharge curve until the end of service life, low self-discharge and leak-resistant sealing, critical characteristics in healthcare equipment where reliability and protection of the device are priorities. The cell contains no added mercury or cadmium and complies with the dimensional and testing requirements of standard IEC 60086, as well as Directive 2006/66/EC on batteries and accumulators.
3. Technical Specifications
The values in the table come from the official specification sheet of Duracell for the LR44 alkaline battery (SIZE LR44, Alkaline Manganese Dioxide Battery) and from the internal product technical data sheet of Cahnos.
| Brand | Duracell (Specialty range) |
| Manufacturer reference | 76A (official Duracell construction for the LR44 cell) |
| IEC designation | LR44 (ANSI/NEDA 1166A) |
| Format equivalents | A76 · AG13 · V13GA · L1154 · LR1154 |
| Electrochemical system | Alkaline manganese (Zn-MnO₂), primary |
| Nominal voltage | 1.5 V |
| Capacity | ≈ 105–110 mAh (105 mAh nominal at 6.8 kΩ, cut-off at 0.8 V, according to Duracell LR44 data sheet) |
| Dimensions | Diameter 11.6 mm × Height 5.4 mm |
| Approximate weight | ≈ 2 g |
| Operating temperature | −20 °C to +54 °C |
| Shelf life | Up to 5 years (storage warranty of the Duracell Specialty LR44 range) |
| Rechargeable | No (single-use primary battery) |
| Presentation | Blister of 2 units |
| Management reference / SKU | 0385019 / 385019 |
| Applicable regulations | IEC 60086 (dimensions and testing) · Directive 2006/66/EC |
| Main use | Clinical thermometers, oximeters, portable medical devices, calculators, remote controls and low-consumption electronics |
Technical data verified against the official specification sheet of Duracell for the LR44 alkaline battery (SIZE LR44, Alkaline Manganese Dioxide Battery) and the internal product technical data sheet of Cahnos.
4. Equivalences and Cross-References
Note on the code: reference 0385019 is the distributor’s management code. The official factory construction of Duracell for this cell is 76A (Specialty LR44) and it must be requested as such in orders or tenders that require the factory code. The LR44 format is an IEC standard (ANSI/NEDA 1166A), so the cell is dimensionally and electrically comparable, at category level, with other 1.5 V alkaline button batteries from other manufacturers, verified one by one by chemistry, voltage and dimensions:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Energizer | A76 (Miniature Alkaline, ANSI/NEDA 1166A) | A76 (official Energizer datasheet) | Comparable by category (not interchangeable 1:1) | Same alkaline Zn-MnO₂ chemistry, 1.5 V and dimensions Ø 11.6 × 5.4 mm; declared typical capacity ≈ 150 mAh at 7.5 kΩ (cut-off 0.9 V, 21 °C) compared to ≈ 105–110 mAh of this Duracell; weight 2.4 g. |
| Varta | V13GA / LR44 (type 4276; factory codes 04276 101 401, EAN 4008496297641) | V13GA | Comparable by category (not interchangeable 1:1) | Alkaline Zn-MnO₂, 1.5 V, Ø 11.6 × 5.4 mm, typical capacity ≈ 125 mAh; same IEC designation LR44; usual presentation in individual blister. |
| Maxell | LR44 (Micro Alkaline; A76 / AG13) | LR44 | Comparable by category (not interchangeable 1:1) | Alkaline, 1.5 V, Ø 11.6 × 5.4 mm, typical capacity ≈ 130–150 mAh depending on discharge rate; mercury-free; check expiry date and manufacturer’s commercial line. |
There is no equivalence table validated by the manufacturer (Duracell) that cross-references this part with cells from other manufacturers; the cross-references indicated have been verified against official data sheets (Duracell LR44 datasheet and Energizer A76 datasheet) and technical distribution documentation, but substitution must be validated field by field (chemistry, voltage, capacity and dimensions) before use in tenders. For equipment that accepts silver oxide chemistry, SR44 / 357 / 303 cells share dimensions and format but deliver 1.55 V with a different discharge curve; they must not be substituted without confirmation in the equipment data sheet. Consult the Cahnos technical department before using this reference in public tenders.
5. Selection tips and variants of interest
Before replacing the battery in your equipment, confirm the format printed in the compartment: LR44 / 76A / A76 / AG13 / V13GA / L1154 indicate this cell of Ø 11.6 × 5.4 mm. If the device indicates SR44, 357 or 303, this is the silver oxide variant (1.55 V) of the same size, which should only be fitted if the equipment manufacturer authorises it.
- Do not mix new batteries with exhausted ones or batteries of different chemistry in the same equipment; respect the polarity (+/−) marked in the compartment.
- Remove exhausted batteries immediately and store stock in a cool, dry place (15–25 °C), away from moisture, to preserve shelf life in storage.
- Manage used batteries as waste in accordance with the batteries and accumulators regulations (RD 106/2008), depositing them at the designated collection points.
Our catalogue also offers other small-format cells for medical devices: the Duracell LR-01 / MN9100 (ref. 0385012 / SKU 385012), the Duracell 389/390 silver oxide (ref. 0385037 / SKU 385037), the Duracell 392/384 SR41 (ref. 0385038 / SKU 385038) and the Maxell SR41 392 (ref. 0018008) as a functional alternative in the same category. For institutional orders or tenders, contact our technical-commercial department to confirm the official reference and the formalised quotation.