Procell Constant Duracell LR06 (AA) 1.5 V industrial alkaline battery – Box of 10 units – Ref. PC1500 / 0385009

4,40 €

Procell Constant Duracell LR06 (AA) alkaline battery, 1.5 V, professional industrial range for intensive use in medical devices: blood pressure monitors, glucose meters, clinical thermometers, oximeters, portable Dopplers, telemetry and equipment remote controls. IEC LR06 (AA) format, official factory construction PC1500 (equivalent to MN1500 and ID1500 from the same manufacturer), supplied in an industrial box of 10 units. Management reference 0385009 (SKU 385009): stable voltage, low self-discharge, leak-resistant seal and stock available with immediate dispatch.

International shipping. Import duties and taxes are payable by the recipient.

Reference
385009

Description

1. Professional alkaline energy for your medical equipment

The Procell Constant Duracell LR06 AA battery is the replacement solution you need to keep portable medical and diagnostic equipment that runs on AA batteries operational. It belongs to the Duracell Procell industrial range, designed for intensive use and continuous supply in clinics, hospitals, surgeries and technical services: digital blood pressure monitors, glucose meters, clinical thermometers, pocket oximeters, fetal Dopplers, examination torches and controls for beds and equipment.

It comes in an industrial box of 10 units, the multi-unit format that allows you to maintain a permanent stock of certified spare parts without depending on supply chain interruptions. An original Duracell battery with the brand guarantee and the reliability required by the healthcare environment.

2. Technical Explanation

This battery is a primary (non-rechargeable) cell with alkaline manganese dioxide and zinc chemistry (Zn-MnO₂), with a nominal voltage of 1.5 V and potassium hydroxide (KOH) electrolyte. Its format corresponds to the IEC LR06 designation (AA size, equivalent to ANSI 15A / MN1500), with standardised dimensions of Ø 13.5–14.5 mm and height 49.2–50.5 mm that guarantee interchangeability with any compartment designed for AA batteries.

The official factory construction of Duracell for this cell is PC1500 (Procell Constant AA range); the same cells are marketed in the consumer line as MN1500 and in the industrial line as ID1500, and should be requested accordingly in orders or tenders that require the factory code. Alkaline technology offers stable discharge until the end of service life, low self-discharge, sealed construction resistant to leakage and reliable operation over a wide temperature range, meeting the requirements of the IEC 60086 standard.

3. Technical Specifications

Parameter Value
Brand / line Duracell – Procell Constant (professional industrial range)
Battery type Alkaline (Zn-MnO₂), primary, non-rechargeable
Format / IEC designation LR06 (AA) – ANSI 15A / MN1500
Official factory construction PC1500 (Procell Constant AA; equivalents MN1500 and ID1500)
Nominal voltage 1.5 V
Typical capacity ≈ 3,125 mAh (according to Procell specification for the PC1500 cell)
Internal impedance ≈ 120 mΩ at 1 kHz (according to PC1500 technical data sheet)
Dimensions (IEC AA standard) Ø 13.5–14.5 mm × 49.2–50.5 mm
Approximate weight ≈ 24 g per unit
Terminals Drawings
Operating range −20 °C to +54 °C
Recommended storage 5 °C to 30 °C, in a clean, dry and ventilated place
Storage life Up to 12 years (Procell Constant family)
Rechargeable No (single-use primary battery)
Presentation Industrial box of 10 units
Management / distributor reference 0385009
SKU Cahnos 385009
Regulatory standard IEC 60086 · ANSI C18.1M · European batteries directive
Main use Blood pressure monitors, glucose meters, thermometers, oximeters, Doppler and portable medical equipment with AA format

The delivered capacity depends on the applied load, operating temperature and cut-off voltage; Duracell publishes the service curves (service hours) of the PC1500 cell in its official technical data sheet (standards IEC 60086-1/2).

4. Equivalences and Cross-References

Note on the code: the reference 0385009 is the distributor’s management code. The official factory construction of Duracell for this cell is PC1500 (Procell Constant AA), equivalent to the MN1500 (consumer line) and ID1500 (industrial line) constructions from the same manufacturer. The AA (LR06) format is an IEC standard, so the cell is dimensionally and electrically comparable, at category level, with other 1.5 V alkaline AA batteries from other manufacturers, verified by chemistry, voltage and dimensions:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Varta Longlife Power LR6 AA (type 4906) 0249031 / SKU 249031 Comparable by category (not interchangeable 1:1) Same alkaline chemistry (Zn-MnO₂), AA format and 1.5 V; blister of 4 units with higher typical capacity (2,970 mAh) and storage life of 10 years.
Maxell Alkaline LR6 AA battery 0632027 / SKU 632027-1 Comparable by category (not interchangeable 1:1) Alkaline, 1.5 V, Ø 13.5–14.5 × 49.2–50.5 mm, typical capacity ≈ 2,100 mAh; blister of 4 units with a minimum order quantity of 40 units and shelf life of 3 years.
Energizer E91 (AA alkaline, IEC LR6 / ANSI 15A) E91 Comparable by category (not interchangeable 1:1) Same alkaline chemistry (Zn-MnO₂), 1.5 V and IEC AA dimensions; official Energizer designation E91 for the AA alkaline cell, typical capacity ≈ 2,850 mAh (discharge at 25 mA); variable commercial presentation.

There is no equivalence table validated by the manufacturer (Duracell) that cross-references this reference with other brands; the cross-references indicated have been verified against official data sheets and technical catalogues (PC1500, E91, Varta type 4906), but substitution must be validated field by field (chemistry, voltage, capacity and dimensions) before use in tenders. Consult the technical department at Cahnos before using this reference in public tenders.

5. Selection tips and variants of interest

Before replacing the battery in your device, check the format printed in the compartment: AA (LR06), AAA (LR03), C (LR14), D (LR20) or 9 V block (6LR61). For this reference, confirm that the device operates with a 1.5 V AA battery; if the equipment supports constant current and frequent use (telemetry, monitoring), quality alkaline chemistry such as this Procell Constant is the appropriate option compared with rechargeable batteries, which deliver a lower voltage (1.2 V).

Usage recommendations: do not mix new batteries with exhausted ones or different brands in the same device, respect polarity (+/−), remove exhausted batteries immediately and store stock at room temperature (15–25 °C) away from moisture to preserve shelf life in storage. Dispose of used batteries as waste in accordance with the batteries and accumulators regulations (RD 106/2008), depositing them at the designated collection points.

Our catalogue includes variants from the same Duracell industrial family: the Procell Constant LR03 AAA (ref. 385011) for lower-consumption devices, the Procell Intense LR14 (ref. 385010), LR20 (ref. 385008) and 6LR61 (ref. 385004) for large formats, as well as the AA alternatives from Varta (ref. 249031) and Maxell (ref. 632027-1) to complete the battery stock for medical devices. For volume orders or tenders, contact our technical-commercial department to confirm the official reference and the formal quotation.

Additional information

Product line

Duracell – Procell Constant (professional industrial range)

Battery type

Alkaline (Zn-MnO2), primary, non-rechargeable

IEC format

LR06 (AA)

Format equivalence

ANSI 15A / MN1500

Factory construction

PC1500 (equivalent to MN1500 consumer / ID1500 industrial)

Nominal voltage

1.5 V

Typical capacity

≈ 3,125 mAh (according to Procell PC1500 specification)

Internal impedance

≈ 120 mΩ at 1 kHz

Dimensions

Ø 13.5–14.5 mm × 49.2–50.5 mm (IEC AA standard)

Approximate weight

≈ 24 g per unit

Terminals

Drawings

Operating range

−20 °C to +54 °C

Storage life

Up to 12 years (Procell Constant family)

Rechargeable

No (single-use primary battery)

Presentation

Industrial box of 10 units

Distributor reference

0385009

Regulatory standard

IEC 60086 · ANSI C18.1M · European batteries directive

Intended use

Blood pressure monitors, glucose meters, thermometers, oximeters, Doppler and portable medical equipment with AA format