Description
1. Professional alkaline energy for your medical equipment
The Procell Constant Duracell LR06 AA battery is the replacement solution you need to keep portable medical and diagnostic equipment that runs on AA batteries operational. It belongs to the Duracell Procell industrial range, designed for intensive use and continuous supply in clinics, hospitals, surgeries and technical services: digital blood pressure monitors, glucose meters, clinical thermometers, pocket oximeters, fetal Dopplers, examination torches and controls for beds and equipment.
It comes in an industrial box of 10 units, the multi-unit format that allows you to maintain a permanent stock of certified spare parts without depending on supply chain interruptions. An original Duracell battery with the brand guarantee and the reliability required by the healthcare environment.
2. Technical Explanation
This battery is a primary (non-rechargeable) cell with alkaline manganese dioxide and zinc chemistry (Zn-MnO₂), with a nominal voltage of 1.5 V and potassium hydroxide (KOH) electrolyte. Its format corresponds to the IEC LR06 designation (AA size, equivalent to ANSI 15A / MN1500), with standardised dimensions of Ø 13.5–14.5 mm and height 49.2–50.5 mm that guarantee interchangeability with any compartment designed for AA batteries.
The official factory construction of Duracell for this cell is PC1500 (Procell Constant AA range); the same cells are marketed in the consumer line as MN1500 and in the industrial line as ID1500, and should be requested accordingly in orders or tenders that require the factory code. Alkaline technology offers stable discharge until the end of service life, low self-discharge, sealed construction resistant to leakage and reliable operation over a wide temperature range, meeting the requirements of the IEC 60086 standard.
3. Technical Specifications
| Parameter | Value |
|---|---|
| Brand / line | Duracell – Procell Constant (professional industrial range) |
| Battery type | Alkaline (Zn-MnO₂), primary, non-rechargeable |
| Format / IEC designation | LR06 (AA) – ANSI 15A / MN1500 |
| Official factory construction | PC1500 (Procell Constant AA; equivalents MN1500 and ID1500) |
| Nominal voltage | 1.5 V |
| Typical capacity | ≈ 3,125 mAh (according to Procell specification for the PC1500 cell) |
| Internal impedance | ≈ 120 mΩ at 1 kHz (according to PC1500 technical data sheet) |
| Dimensions (IEC AA standard) | Ø 13.5–14.5 mm × 49.2–50.5 mm |
| Approximate weight | ≈ 24 g per unit |
| Terminals | Drawings |
| Operating range | −20 °C to +54 °C |
| Recommended storage | 5 °C to 30 °C, in a clean, dry and ventilated place |
| Storage life | Up to 12 years (Procell Constant family) |
| Rechargeable | No (single-use primary battery) |
| Presentation | Industrial box of 10 units |
| Management / distributor reference | 0385009 |
| SKU Cahnos | 385009 |
| Regulatory standard | IEC 60086 · ANSI C18.1M · European batteries directive |
| Main use | Blood pressure monitors, glucose meters, thermometers, oximeters, Doppler and portable medical equipment with AA format |
The delivered capacity depends on the applied load, operating temperature and cut-off voltage; Duracell publishes the service curves (service hours) of the PC1500 cell in its official technical data sheet (standards IEC 60086-1/2).
4. Equivalences and Cross-References
Note on the code: the reference 0385009 is the distributor’s management code. The official factory construction of Duracell for this cell is PC1500 (Procell Constant AA), equivalent to the MN1500 (consumer line) and ID1500 (industrial line) constructions from the same manufacturer. The AA (LR06) format is an IEC standard, so the cell is dimensionally and electrically comparable, at category level, with other 1.5 V alkaline AA batteries from other manufacturers, verified by chemistry, voltage and dimensions:
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Varta | Longlife Power LR6 AA (type 4906) | 0249031 / SKU 249031 | Comparable by category (not interchangeable 1:1) | Same alkaline chemistry (Zn-MnO₂), AA format and 1.5 V; blister of 4 units with higher typical capacity (2,970 mAh) and storage life of 10 years. |
| Maxell | Alkaline LR6 AA battery | 0632027 / SKU 632027-1 | Comparable by category (not interchangeable 1:1) | Alkaline, 1.5 V, Ø 13.5–14.5 × 49.2–50.5 mm, typical capacity ≈ 2,100 mAh; blister of 4 units with a minimum order quantity of 40 units and shelf life of 3 years. |
| Energizer | E91 (AA alkaline, IEC LR6 / ANSI 15A) | E91 | Comparable by category (not interchangeable 1:1) | Same alkaline chemistry (Zn-MnO₂), 1.5 V and IEC AA dimensions; official Energizer designation E91 for the AA alkaline cell, typical capacity ≈ 2,850 mAh (discharge at 25 mA); variable commercial presentation. |
There is no equivalence table validated by the manufacturer (Duracell) that cross-references this reference with other brands; the cross-references indicated have been verified against official data sheets and technical catalogues (PC1500, E91, Varta type 4906), but substitution must be validated field by field (chemistry, voltage, capacity and dimensions) before use in tenders. Consult the technical department at Cahnos before using this reference in public tenders.
5. Selection tips and variants of interest
Before replacing the battery in your device, check the format printed in the compartment: AA (LR06), AAA (LR03), C (LR14), D (LR20) or 9 V block (6LR61). For this reference, confirm that the device operates with a 1.5 V AA battery; if the equipment supports constant current and frequent use (telemetry, monitoring), quality alkaline chemistry such as this Procell Constant is the appropriate option compared with rechargeable batteries, which deliver a lower voltage (1.2 V).
Usage recommendations: do not mix new batteries with exhausted ones or different brands in the same device, respect polarity (+/−), remove exhausted batteries immediately and store stock at room temperature (15–25 °C) away from moisture to preserve shelf life in storage. Dispose of used batteries as waste in accordance with the batteries and accumulators regulations (RD 106/2008), depositing them at the designated collection points.
Our catalogue includes variants from the same Duracell industrial family: the Procell Constant LR03 AAA (ref. 385011) for lower-consumption devices, the Procell Intense LR14 (ref. 385010), LR20 (ref. 385008) and 6LR61 (ref. 385004) for large formats, as well as the AA alternatives from Varta (ref. 249031) and Maxell (ref. 632027-1) to complete the battery stock for medical devices. For volume orders or tenders, contact our technical-commercial department to confirm the official reference and the formal quotation.





Reviews