Battery 6V 7Ah SLA for Electrocardiograph Philips PageCardiette 100 MFR | Original Replacement M2460A · Ref. 88888260

33,60 €

Sealed lead-acid (SLA) battery, 6V 7Ah designed as a replacement for the original reference Philips M2460A for the PageCardiette 100 MFR electrocardiograph and the PageWriter 100/200/300PI family. Leak-proof, rechargeable and maintenance-free VRLA/AGM technology, with T1 terminals (Faston 0.187 inches) and cell format 151 × 34 × 97.5 mm. High autonomy for continuous ECG recordings in consulting rooms, emergency departments and primary care, with direct installation reusing the equipment wiring. Cahnos warranty and technical-commercial support for institutional orders and tenders.

International shipping. Import duties and taxes are payable by the recipient.

Datasheet (opens in a new tab)

Reference
88888260

Description

Keep your electrocardiograph Philips PageCardiette 100 MFR always operational with this sealed lead-acid battery, 6 V and 7 Ah, a replacement that reproduces the performance of the original battery, reference M2460A. It is the suitable spare part for hospitals, cardiology clinics, emergency departments and diagnostic centres that need reliable autonomy during clinical activity, without depending on the mains supply or interrupting examinations. Rechargeable, leak-proof and maintenance-free: the most cost-effective technical-commercial solution compared with the original replacement, with the warranty and support of Cahnos.

How this battery works

The battery uses valve-regulated lead-acid (VRLA) chemistry with absorbed glass mat (AGM) electrolyte, making it leak-proof, rechargeable and suitable for portable medical equipment. It supplies a nominal voltage of 6 V with a capacity of 7 Ah (20-hour rate), sufficient to power the ECG recording, display and electronics of the PageCardiette 100 MFR for full working days. Its sealed construction allows spill-free installation in the equipment compartment, reusing the original wiring with T1 terminals. Like any VRLA cell, it offers a typical design life of 3 to 5 years under nominal use and charging conditions, with excellent recovery after moderate discharges. Indicative charging values for a 6 V VRLA cell: cycle 7.20–7.35 V and float 6.80–6.90 V (always verify the equipment charger parameters).

Technical specifications

Characteristic Specification
Reference Cahnos (SKU) 88888260
Original manufacturer reference Philips M2460A
Battery type Sealed lead-acid (SLA / VRLA), maintenance-free
Technology AGM, absorbed glass mat electrolyte
Nominal voltage 6 V
Nominal capacity 7 Ah (20-hour rate)
Terminals T1 / Faston 0.187 inches (4.8 mm)
Dimensions (L × W × H) 151 × 34 × 97.5 mm
Approximate weight 1.2-1.3 kg
Rechargeable Yes
Maintenance Maintenance-free
Estimated life 3-5 years under nominal conditions (typical VRLA)
Compatible equipment Philips PageCardiette 100 MFR; PageWriter 100/200/300PI family (M1770A, M1771A, M1772A) according to specialised distribution documentation; verify compartment
Presentation Unit

Equivalences and cross-references

The M2460A battery conforms to the standard sealed lead-acid cell format of 6 V and 7 Ah with Faston T1 terminals (reference cell format Yuasa NP7-6 / CSB GP672). The references from other manufacturers listed below belong to this same product category (6 V, 7 Ah VRLA/AGM battery) and have been cross-checked against official manufacturer datasheets and cross-reference tables from specialised distribution; they are classified as comparable by category, not 1:1 interchangeable: before replacement, the terminal type, dimensions and polarity must be verified against the compartment of the specific electrocardiograph.

Manufacturer / Brand Family / Model Code / reference Equivalence level Technical differences / Remarks
CSB Battery GP series (VRLA / AGM) GP672 Comparable by category (not interchangeable 1:1) 6 V / 7.2 Ah, Faston 4.75 mm terminals, 151 × 34 × 94 mm (up to ≈100 mm with terminal), ≈1.22 kg, up to 5 years in standby service. Confirmed in official CSB datasheet; nominal capacity 7.2 Ah and verify terminal.
GS Yuasa NP series (VRLA) NP7-6 Comparable by category (not interchangeable 1:1) 6 V / 7 Ah, Faston 4.8 mm terminals, 151 × 34 × 97.5 mm (height over terminals), ≈1.32 kg. Confirmed in official manufacturer datasheet; slightly taller, verify compartment.
Power-Sonic PS Series (AGM) PS-670 Comparable by category (not interchangeable 1:1) 6 V / 7 Ah AGM with Faston F1/T1 terminals and dimensions 151 × 34 × 97.5 mm (approx.). Confirmed in official manufacturer datasheet; verify height, terminal orientation and terminal type of the batch.
Panasonic LC series (sealed lead-acid) LC-R067R2P Comparable by category (not interchangeable 1:1) 6 V / 7.2 Ah, 151 × 34 × 97 mm, Faston terminals. Confirmed in official manufacturer datasheet and specialised distribution catalogues; nominal capacity 7.2 Ah and verify height dimension.
Raion Power RG series (medical battery) RG0670T1 Comparable by category (not interchangeable 1:1) 6 V / 7 Ah with T1 terminals (Faston 0.187 inches), documented as a direct replacement for the Philips M2460A in PageWriter 300PI equipment in the manufacturer datasheet. Same performance; verify dimensions and terminal orientation.

There is no equivalence table validated by the equipment manufacturer that authorises third-party batteries; consult the technical department before using in tenders. Before a replacement, the following must be verified one by one: voltage (6 V), capacity (7 Ah), chemistry (sealed lead-acid VRLA/AGM), terminal type (T1 / Faston 0.187 inches) and compartment dimensions (standard 6 V 7 Ah cell format).

Selection tips and variants of interest

Identify the exact model of your equipment: this 6 V / 7 Ah battery is the one indicated for the Philips PageCardiette 100 MFR electrocardiograph (original reference M2460A) and shares the format with the PageWriter 100/200/300PI family; always confirm the compartment, terminal type (T1) and polarity orientation before mounting. Do not swap it for cells of a different voltage or with integrated wiring without prior technical validation.

Prevention and maintenance: VRLA cells self-discharge slowly at rest; if the equipment is to remain off for long periods, recharge it periodically to prevent the voltage from dropping below the recovery threshold (≈5.25 V in a 6 V cell). Replace the battery when recording autonomy is noticeably reduced or the equipment warns of low battery.

Variants of the same Philips family at Cahnos: 12 V / 2.9 Ah battery for PageWriter Trim 2 (ref. 88888782) and 11.1 V / 7.8 Ah lithium-ion battery for PageWriter TC30/50/70 (ref. 88888895). Do not interchange these references between models: each unit accepts a specific voltage and capacity. For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department to confirm compatibility, lead times and a formal quotation.

Additional information

Nominal voltage

6 V

Nominal capacity

7 Ah (7,000 mAh / ≈42 Wh)

Energy

≈42 Wh

Approximate weight

≈1.1 kg

Manufacturer reference

Philips M2460A

Compatibility

Electrocardiograph Philips PageCardiette 100 (MFR M2460A)

Rechargeable

Yes

Installation

Direct fit in the original compartment, without adaptations; respect polarity

Battery type

Sealed lead-acid (SLA / VRLA)

Technology

AGM, absorbed glass mat electrolyte

Voltage

6 V

Capacity

7 Ah (20-hour rate)

Terminals

T1 / Faston 0.187 inches (4.8 mm)

Dimensions

151 x 34 x 97.5 mm

Weight

Approx. 1.2-1.3 kg

Maintenance

Maintenance-free

Estimated life

3-5 years (typical VRLA)

Compatible equipment

Philips PageCardiette 100 MFR; PageWriter 100/200/300PI (M1770A, M1771A, M1772A)