We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Rechargeable Ni-Cd battery 3.6V 750mAh for Welch Allyn 72200 otoscope | Ref. 88888643

25,60 €

Rechargeable nickel-cadmium (Ni-Cd) battery, 3.6 V and 750 mAh for otoscopes and Welch Allyn diagnostic handles model 72200 and compatible family (71670, 71000, 71020, 71054, 11720 and others). Directly replaces the original reference Welch Allyn 78904586, with the same voltage, chemistry and spring contact system: restores stable handle illumination and ensures reliable diagnosis in consulting rooms, primary care and ear, nose and throat (ENT) services.

International shipping. Import duties and taxes are payable by the recipient.

Reference
88888643

Description

At Cahnos we provide the rechargeable 3.6 V, 750 mAh battery for the Welch Allyn 72200 otoscope (Cahnos reference 88888643), a spare part technically equivalent to the original cell of the diagnostic handle, designed for medical electronics services, hospital maintenance, clinics and institutional purchasing departments that require traceable spare parts of consistent quality. By restoring the equipment’s rated voltage and capacity, this battery restores the brightness of the otoscope head without having to replace the complete handle, extending the service life of your device fleet with an excellent cost-performance ratio compared with the original part.

1. What this battery is and why it is critical in the otoscope 72200

The otoscope is the instrument used to examine the external auditory canal and the tympanic membrane. In the diagnostic handles of the Welch Allyn 72200 family, power is not supplied by ordinary batteries but by an internal rechargeable nickel-cadmium (Ni-Cd) battery, 3.6 V, housed inside the handle and recharged using the equipment’s base or desktop charger. Ni-Cd chemistry provides a very stable discharge voltage and high resistance to frequent charge/discharge cycles, essential qualities in a device used daily in the consulting room: if the battery loses capacity or voltage, the head bulb loses intensity and diagnostic quality deteriorates. This battery is installed directly in the handle (spring contact, positive terminal to the bottom) and is the reference that covers, in addition to the 72200, the Welch Allyn 71670, 71000, 71020, 71054, 11720 and other handles in the same diagnostic family, replacing the original part number 78904586.

2. Technical specifications

Data cross-checked against the distributor’s technical data sheet (ref. 88888643) and against the specifications of the original Welch Allyn 78904586 part documented by authorised medical spare parts distributors.

Parameter Specification
Reference Cahnos (SKU) 88888643
Replaced original reference Welch Allyn 78904586
Battery type Rechargeable nickel-cadmium (Ni-Cd) battery
Nominal voltage 3.6 V
Nominal capacity 750 mAh (pack data sheet: 0.80 Ah)
Energy ≈ 2.7 Wh
Approximate dimensions 73.3 x 28.5 x 25.7 mm
Approximate weight ≈ 109 g
Rechargeable Yes, with the Welch Allyn handle base or desktop charger
Compatibility (pack manufacturer’s data sheet) Welch Allyn otoscope 72200; handles 71670, 71000, 71020, 71054 and 11720
Extended compatibility documented in the sector Handles 20000, 71050, 71051, 71055, 71110, 71150, 71610, 72207, 74710, 97210, 11730, 18100, 18200, 21700, 74054 and WA-72200 (same 3.6 V cell format)
Application Otoscopy and ENT examination: practice, primary care, occupational medicine
Presentation 1 unit
Recycling Dispose of in accordance with WEEE regulations (rechargeable battery)

Note: the capacity is listed as 750 mAh in the commercial reference; the pack’s technical data sheet (ref. 88888643) declares 0.80 Ah. Before replacing, check the reference stamped on the installed battery and the condition of the handle charger.

3. Equivalences and cross-references

The 3.6 V, 750 mAh Ni-Cd cell is widely documented in the sector as the replacement for Welch Allyn diagnostic handles (original reference 78904586) and for handles of other brands sharing the same cell format. There is no official equivalence table published by Welch Allyn authorising third-party batteries for this reference; the cross-references listed below have been checked against medical spare parts distributors and are classified as comparable by category, not 1:1 interchangeable.

Manufacturer / Brand Family / Model Code / Reference Equivalence level Technical differences / Remarks
Welch Allyn Original battery for diagnostic handles (3.6 V, 750 mAh, Ni-Cd) 78904586 Comparable by category (not interchangeable 1:1) Original reference of the equipment manufacturer that this battery replaces: same voltage (3.6 V), same Ni-Cd chemistry and same capacity (750 mAh / 2.7 Wh). Consistently documented at medical spare parts distributors (BatteryWeb, BBM Battery, MPF Products, BatteryShip).
Cardinal Health (Cardinal Medical) Replacement battery for 3.6 V diagnostic handles CJB-191 Comparable by category (not interchangeable 1:1) Rechargeable Ni-Cd pack, 3.6 V and 750 mAh, with the same cell format and spring contact, intended for otoscope and ophthalmoscope handles. Confirmed in a medical spare parts distributor catalogue.
Keeler / Medic Lux Battery for VISTA 200 / LUX VISTA handles (1919-P) 1919-P-5020 Comparable by category (not interchangeable 1:1) Same electrical specification (3.6 V, 750 mAh, Ni-Cd) for otoscope/ophthalmoscope diagnostic handles; check the handle housing and contacts before replacing. Confirmed in a medical spare parts distributor catalogue.

There is no manufacturer-validated equivalence table cross-referencing this part with third-party batteries for Welch Allyn handles; consult the technical department before use in tenders. Do not confuse this single-cell 3.6 V battery (diagnostic handles with charging base) with the batteries of other fibre-optic otoscopes with AA battery handles or with rechargeable handles of a different voltage: the chemistry, physical format and contact system are specific to the Welch Allyn 72200 handle.

4. Selection advice and relevant variants

Identify the exact model: confirm that your equipment is a Welch Allyn diagnostic handle from the 72200 family and note the reference stamped on the installed battery (78904586 or another) before ordering the replacement. Installation: insert the battery with the positive pole towards the bottom of the handle and respect the travel of the spring contact; charging is carried out with the equipment’s base or desktop charger, never with chargers from other families. Preventive maintenance: with Ni-Cd chemistry, avoid repeated deep discharges and allow a periodic full charge; replace the cell when there is a notable loss of autonomy or when the head light loses intensity appreciably. Cell replacement: if your technical service rebuilds packs, always use Ni-Cd cells of the same voltage and capacity; do not mix new cells with used ones. Environmental management: take the exhausted battery to an authorised collection point (WEEE); never dispose of it in the general waste container. For institutional orders, tenders or continuous supply contracts, contact our technical-commercial department to confirm exact compatibility with your fleet of Welch Allyn handles, lead times and a formal quotation.

Additional information

Accumulator type

Ni-Cd (nickel-cadmium), rechargeable

Nominal voltage

3.6 V

Nominal capacity

750 mAh (0.75 Ah)

Energy

≈ 2.7 Wh

Manufacturer reference

78904586 (Welch Allyn)

Compatibility

Welch Allyn 72200, 71670, 71000, 71020, 71054, 11720 and diagnostic handle family (20000, 71050, 97210, 72207, 11730, 18100, 18200, 21700, 74054, WA-72200)

Indicative dimensions

≈ 73 x 28.5 x 25.7 mm (according to standard market assembly)

Approximate weight

≈ 0.09 kg (indicative)

Rechargeable

Yes, with the Welch Allyn handle base or desktop charger

Installation

Direct replacement in the instrument handle, without tools

Use

Otoscopy and ENT diagnostics with Welch Allyn instruments

Recycling

WEEE (rechargeable battery)

Battery type

Rechargeable nickel-cadmium (Ni-Cd)

Voltage

3.6 V

Capacity

750 mAh (0.75 Ah; pack data sheet 0.80 Ah)

Dimensions

Approx. 73.3 x 28.5 x 25.7 mm

Weight

≈ 109 g

Replaced reference

Welch Allyn 78904586

Application

Otoscopy and ENT examination: practice, primary care, occupational medicine

Presentacion

Unit

Reviews

There are no reviews yet.

Be the first to review “Rechargeable Ni-Cd battery 3.6V 750mAh for Welch Allyn 72200 otoscope | Ref. 88888643”

Your email address will not be published. Required fields are marked *