Original Physio-Control LIFEPAK CR2 Battery – MFR 11141-000165 (11141000165), Lithium 12 V for CR2 Defibrillator | Ref. 88889783

496,00 €

Original Physio-Control LIFEPAK CR2 battery (MFR 11141-000165) lithium manganese dioxide, 12 V, non-rechargeable, with 4 years of standby life. Official replacement for the LIFEPAK CR2 automated external defibrillator: maintains daily self-tests and provides approximately 166 shocks at 200 J, 103 shocks at 360 J or around 800 minutes of operation before requiring replacement. Reference confirmed in the GUDID regulatory database (UDI-DI 00883873867792); supplied with mounting instructions. Essential for AED maintenance programmes, emergency services, patient transport and hospital purchasing. Ref. Cahnos 88889783, price per unit.

International shipping. Import duties and taxes are payable by the recipient.

Reference
88889783

Description

1. Backup power for your LIFEPAK CR2 defibrillator

The Physio-Control LIFEPAK CR2 battery sold by Cahnos (factory reference 11141-000165, catalogued format 11141000165; Cahnos SKU 88889783) is the original power replacement for the LIFEPAK CR2 automated external defibrillator (AED), one of the most widely used defibrillation devices in out-of-hospital care, medical transport, workplaces and public access defibrillation programmes. It is a primary lithium manganese dioxide (LiMnO₂) cell, non-rechargeable, 12 V, designed to keep the device in full readiness for years with minimal maintenance. An essential spare part for maintenance services, biomedical engineering and purchasing departments that need traceable replacements with a confirmed factory reference, ready for use in emergencies.

2. What it is and why this battery is critical in an AED

The LIFEPAK CR2 is an automated external defibrillator for life support that analyses heart rhythm and delivers biphasic shocks in case of cardiac arrest. Its availability depends entirely on an autonomous power source: the internal battery powers the device’s daily, weekly and monthly self-tests, rhythm analysis, voice instructions and the shock. That is why AED maintenance programmes require batteries to be replaced preventively, according to the installation date indicated on the label, without waiting for the device to signal depletion.

This reference uses primary lithium manganese dioxide (LiMnO₂) chemistry, sealed and non-rechargeable: it requires no charger or charge cycles and retains its stored energy for years, making it ideal for an emergency device that must remain in constant readiness. With a new battery at 20 °C, the manufacturer’s technical documentation indicates approximately 166 shocks at 200 J (with one minute of CPR between shocks), 103 shocks at 360 J or about 800 minutes of continuous operation, with a service life of 4 years in standby installed in the device. Replacement is carried out in seconds without tools: remove the depleted battery, insert the new one and the device is operational.

3. Technical Specifications

Data verified against the regulatory register GUDID (FDA), the device manufacturer’s technical documentation and specialised distribution:

Parameter Specification
Reference Cahnos (SKU) 88889783
Manufacturer reference (MFR) 11141-000165 — catalogued format 11141000165 (Physio-Control / Stryker)
Regulatory confirmation GUDID (FDA): UDI-DI 00883873867792, description LIFEPAK CR2 AED Lithium Battery, in the name of PHYSIO-CONTROL, INC.
Battery type Lithium manganese dioxide (LiMnO2), primary cell, non-rechargeable
Nominal voltage 12.0 V
Capacity Approx. 4.7 Ah (≈ 55.8 Wh); internal catalogue Cahnos records it as 12 V / 4.85 Ah
Standby life 4 years installed in the device with daily checks
Performance (new battery at 20 °C) Approx. 800 minutes of operation; 166 shocks at 200 J or 103 shocks at 360 J (with 1 min of CPR between shocks)
Rechargeable No — preventive replacement
Compatibility Automated external defibrillator (AED) Physio-Control LIFEPAK CR2
Device software Verify version 1.12 or higher before installing (according to specialised distribution technical data sheet)
Contents 1 battery + replacement instructions
Approximate weight Approx. 0.32 kg (according to distributor data sheet)
Presentation 1 unit

Technical note: the nominal voltage of this battery is 12.0 V. Commercial references quoting 16.8 V correspond to the charging voltage of 4-cell (4S) rechargeable lithium-ion packs from other families and do not apply to this reference, which is a non-rechargeable 12 V primary cell. Before mounting, always check the label of the received battery and the installation deadline indicated by the manufacturer.

4. Equivalences and Cross-References

The reference 11141-000165 is confirmed in the GUDID regulatory database (Physio-Control, Inc., UDI-DI 00883873867792, description LIFEPAK CR2 AED Lithium Battery). The code catalogued by Cahnos as 11141000165 is the same official part number in concatenated format (without hyphens), so there is no intermediate distributor code. The references from manufacturers and independent spare parts suppliers listed below belong to this same category, have been verified against battery manufacturer catalogues and specialised distribution, and are classified as comparable by category, not 1:1 interchangeable: before replacement, voltage (12 V), chemistry (LiMnO₂ vs Li-Ion), connector and compartment housing must be verified.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Physio-Control (Stryker) Official LIFEPAK CR2 AED Battery 11141-000165 Exact reference equivalence (same manufacturer) Same battery: official part number of the analysed product (catalogue format 11141000165); confirmed in GUDID with UDI-DI 00883873867792.
Physio-Control (Stryker) Related reference LIFEPAK CR2 11141-000163 Not verified Reference from the same family consistently cited by distributors and spare parts suppliers as compatible with the LIFEPAK CR2 (12 V / ≈ 4.65 Ah); not identified as identical to 11141-000165 in the open official catalogue; confirm with the manufacturer before use.
MedicalBatteryDirect (spare parts supplier) LIFEPAK CR2 AED replacement battery MBD11154 Comparable by category (not interchangeable 1:1) Independent Li-Ion cell replacement, 12 V / 55.8 Wh (4 cells); advertised as compatible with the CR2 and with reference 11141-000163; check connector and housing; not authorised by the equipment manufacturer.
KingSener (BatteryMall) LIFEPAK CR2 replacement battery 11141-000163 (independent replacement) Comparable by category (not interchangeable 1:1) 12 V / ≈ 4.65 Ah (55.8 Wh) replacement for the LIFEPAK CR2; independent spare parts manufacturer; validate assembly and connector before replacing.

There is no equivalence table validated by the manufacturer (Physio-Control / Stryker) authorising third-party batteries for the LIFEPAK CR2 model; consult the technical department before use in tenders. AED batteries are proprietary and differ in connector, voltage, chemistry and electronic management: batteries from other LIFEPAK series are also not interchangeable (CR Plus 11403-000001, LIFEPAK 1000 111141-000100 or LIFEPAK 500 11141-000158), each with its own specific voltage, chemistry and housing.

5. Selection tips and variants of interest

  • Identify the exact model of your device: this 12 V battery is exclusive to the LIFEPAK CR2 defibrillator. Do not install it in other models of the LIFEPAK family, whose batteries (CR Plus, LIFEPAK 1000, LIFEPAK 500) are not compatible with each other.
  • Preventive replacement: replace the battery every 4 years from its installation in the device or at the first low battery warning; observe the installation deadline printed on the label before putting it into service.
  • Do not attempt to recharge it: it is a long-life disposable primary cell; it does not accept chargers or charge cycles.
  • Before installing, check that the LIFEPAK CR2 has software version 1.12 or higher, as recommended by the technical documentation of specialised distribution.
  • Plan spare stock in AED fleets: keep at least one reserve battery per device for immediate replacement and avoid periods when the defibrillator is out of service.
  • Accessories from the same family: complete the maintenance with the original LIFEPAK CR2 consumables, such as the Quick-Step electrode pack (ref. 11101-000021) or the replacement cover (ref. 11512-000001), available on the authorised spare parts market.
  • Recycling: do not dispose of the used battery as municipal waste; manage it in accordance with the waste electrical and electronic equipment regulations (WEEE).

For institutional orders, tenders or ongoing supply contracts, contact our technical-commercial department to confirm compatibility with your defibrillator fleet, delivery times and formal quotation.

Additional information

Manufacturer reference

11141-000165 (catalogued format 11141000165) – Physio-Control / Stryker

Battery type

Lithium manganese dioxide (LiMnO2), primary cell, non-rechargeable

Chemistry

Lithium manganese dioxide (Li/MnO2)

Nominal voltage

12.0 V

Nominal capacity

4.65 – 4.7 Ah (4,650 – 4,700 mAh)

Energy

≈ 55.8 Wh

Dimensions

≈ 180 × 60 × 22 mm

Approximate weight

≈ 0.32 kg

Installed life

4 years (with daily tests)

Storage life

5 years uninstalled

Yield

≈ 800 min of operation; 166 shocks at 200 J or 103 at 360 J (20 °C)

Operating temperature

0 °C to 50 °C

Storage temperature

0 °C to 25 °C (long-term)

Compatibility

Automated external defibrillator (AED) Physio-Control LIFEPAK CR2

Installation

Direct replacement in the equipment compartment

Maintenance

No maintenance or charge cycles

Regulatory registration

GUDID (FDA): UDI-DI 00883873867792 – PHYSIO-CONTROL, INC.

Recycling

Manage in accordance with WEEE regulations

Capacity

≈ 4.7 Ah (≈ 55.8 Wh); internal catalogue 12 V / 4.85 Ah

Standby life

4 years installed with daily checks

Rechargeable

No

Required software

Version 1.12 or higher on the device (according to specialised distribution)

Contents

1 battery + replacement instructions