Description
1. Backup power for your Defibtech defibrillator
At Cahnos we offer you the replacement battery that corresponds to the original unit of the Defibtech DSA-DEA and Lifeline AED defibrillators (factory ref. DBP-2800, also coded DCF-210 and DCF-E210 on certain channels, and identified in our catalogue under reference 88888931). It is a non-rechargeable primary lithium cell of 15 V and 2.8 Ah, designed to keep the AED permanently in “ready-to-use” mode for up to 7 years, with no charging or maintenance routines.
It is the essential spare part for emergency services, ambulances, civil protection, workplaces, sports facilities and public-access defibrillation points that manage equipment from the DSA-DEA / Lifeline AED family of the DDU-1XX series, ensuring an immediate response to cardiac arrest.
2. How this battery works: technical explanation
The automated external defibrillator (AED) of the DSA-DEA / Lifeline AED family operates exclusively on battery: while at rest, the unit performs daily, weekly, monthly and quarterly self-tests that verify the condition of the cell, the electronics and the electrodes. In an emergency, the stored energy powers the rhythm analysis electronics, the voice prompts and the capacitor charge/discharge stage to deliver biphasic therapy.
This battery uses non-rechargeable primary lithium chemistry (lithium-manganese dioxide type, Li-MnO₂), single-use: its very low self-discharge allows it to remain installed for years with full response capacity. The pack also incorporates a 9 V auxiliary battery, model DAC-410, which independently powers the unit’s self-tests, leaving the main energy reserved for assistance. When depletion approaches, the defibrillator warns via an indicator light and acoustic signal; replacement is carried out by removing the exhausted battery and inserting the new one into the compartment, without tools. Due to its disposable nature, stock management must be carried out by expiry date (FIFO rotation).
3. Technical Specifications
| Parameter | Specification |
| Reference Cahnos (SKU) | 88888931 (distribution code) |
| Manufacturer reference (MFR) | DBP-2800, also referred to as DCF-210 and DCF-E210 (Defibtech) |
| Regulatory registration | GUDID/FDA: UDI-DI 00815098020379 and 10815098020376 (DEFIBTECH, L.L.C., brand “DDU-1XX Series Battery Pack”, model DBP-2800, GMDN Primary battery, class III according to FDA, product code MKJ). Reference verified on AccessGUDID. |
| Battery type | Primary lithium cell, non-rechargeable (single-use) |
| Chemistry | Lithium (lithium-manganese dioxide type, Li-MnO₂) |
| Nominal voltage | 15 V |
| Nominal capacity | 2.8 Ah (2800 mAh) |
| Stored energy | ≈ 42 Wh (15 V × 2.8 Ah) |
| Standby autonomy | Up to 7 years installed (includes daily, weekly, monthly and quarterly self-tests of the device) |
| Shock capacity | Up to 300 shocks or 16 hours of continuous monitoring |
| Auxiliary self-test battery | 9 V battery model DAC-410 (included in the pack) |
| Rechargeable | No (primary battery; replace with a new unit) |
| Maintenance | Maintenance-free; replace by expiry date |
| Compatibility | Defibtech DSA-DEA, Lifeline AED (DDU-100) and Lifeline AUTO (DDU-120), DDU-1XX series |
| Low battery warning | Visual indicator and audible signal |
| Installation | Direct replacement in the AED compartment, without tools |
| Presentation | 1 unit |
| Recycling | Management in accordance with WEEE regulations (regulated lithium transport) |
4. Equivalences and Cross-References
The official reference of the pack is DBP-2800, confirmed in the GUDID/FDA regulatory database in the name of DEFIBTECH, L.L.C. under the brand “DDU-1XX Series Battery Pack” with GMDN “Primary battery” and FDA class III classification (verified on AccessGUDID). The designations DCF-210 and DCF-E210 correspond to the same assembly (high-capacity pack for Lifeline AED that includes the 9 V auxiliary battery DAC-410) and are the codes under which it is distributed on certain channels: exact reference equivalence within the same manufacturer Defibtech. Defibtech does not publish an equivalence table authorising third-party batteries for the DSA-DEA / Lifeline AED family; the listed alternatives share the same typology (lithium battery for AED) and are classified as comparable by category, not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Defibtech | DSA-DEA battery 5 years / 125 shocks (same DDU-1XX equipment family) | DBP-1400 (Cahnos 88888845) | Comparable by category (not interchangeable 1:1) | Same Li-MnO₂ chemistry and 15 V, but 1.4 Ah capacity: up to 5 years in standby and 125 discharges. Mechanically suitable for the same equipment; lower performance than the DBP-2800. |
| Kingsener | Aftermarket replacement for Defibtech Lifeline AED | Kingsener DBP-2800 (15 V / 2800 mAh) | Comparable by category (not interchangeable 1:1) | Third-party replacement battery, lithium-ion chemistry, which declares compatibility with the Lifeline AED family; verify voltage (15 V), capacity (2.8 Ah), connector and compartment housing against the removed unit. |
| AolsteCell | Replacement for DDU-100, DBP-2800 and DBP-1400 | AolsteCell DBP-2800 | Comparable by category (not interchangeable 1:1) | Third-party replacement battery that declares compatibility with the DDU-1XX family; validate chemistry, connector and compartment geometry before replacement. |
| Philips | HeartStart FR3 | 989803150161 (Cahnos 88888783) | Comparable by category (not interchangeable 1:1) | Lithium 12 V / 4.2 Ah for the FR3 AED; voltage, connector and management electronics exclusive to Philips. |
| ZOLL | AED Pro non-rechargeable battery | 8000-0860-01 (Cahnos 88888634) | Comparable by category (not interchangeable 1:1) | Same Li-MnO₂ chemistry and non-rechargeable, but 12 V / 4.2 Ah; proprietary connector and management electronics of the AED Pro. |
There is no equivalence table validated by the manufacturer (Defibtech) that cross-references the DBP-2800 with third-party batteries; consult the technical department before use in tenders. Before accepting an alternative battery, each of the following must be verified one by one: voltage (15 V), capacity (2.8 Ah), chemistry (non-rechargeable primary lithium), presence of the 9 V auxiliary battery for self-test (DAC-410), connector and compartment dimensions. Batteries from other AEDs on the market (e.g. Philips HeartStart FR3, ZOLL AED Pro, CU Medical i-PAD or Welch Allyn AED 10) share the same typology but are not interchangeable due to proprietary connector and management electronics.
5. Selection tips and variants of interest
Identify the exact model: this battery corresponds to the Defibtech DSA-DEA, Lifeline AED (DDU-100) and Lifeline AUTO (DDU-120) defibrillators of the DDU-1XX series. It is not compatible with the Lifeline VIEW / ECG / PRO family (DDU-2000 series), which uses the DBP-2003 / DCF-2003 pack (Cahnos 88888935).
Verify the printed reference: before ordering, confirm on the removed battery the code DBP-2800 (or DCF-210); if your unit works with another pack, do not force the replacement.
Expiry management: as it is a non-rechargeable primary battery, establish a FIFO stock rotation and replace the unit before its expiry date even if the unit has not recorded any discharges. Attend to the low-battery warnings from the self-test with a new verified unit.
Lower-capacity variant in the same family: if your defibrillation programme does not require 300 discharges per cycle, the Defibtech DBP-1400 battery of 5 years / 125 discharges (ref. Cahnos 88888845) shares chemistry, voltage and equipment family, with lower capacity.
Accessories: also check the condition and expiry date of the defibrillation electrodes of the unit to keep the defibrillation point fully operational.
Recycling: dispose of the exhausted battery at the authorised WEEE collection points in accordance with current regulations. For volume orders or tenders, contact the technical department of Cahnos indicating model, serial number and reference of the installed battery; we will confirm compatibility before formalising the order.