Description
1. Introduction
The ZOLL CPR-D•PADZ adult electrode (ref. 8900-0800-01) is the official replacement for pre-connected electrodes for ZOLL automated external defibrillators (AEDs) and life support equipment. Its single-piece design combines the anterior and posterior electrodes in a single element, eliminating placement errors in high-stress situations. It is the recommended choice for emergency services, ambulances, workplace AED centres and hospital environments that need reliable, verified performance during cardiopulmonary resuscitation. It is supplied as 1 pair (1 single piece with both electrodes).
2. Technical explanation of the equipment and procedure
The CPR-D•PADZ electrodes incorporate ZOLL’s Real CPR Help® technology: an integrated sensor detects chest movement during compressions and transmits rate and depth data of the CPR to the defibrillator, allowing the device to provide voice instructions and an adaptive metronome in real time. In this way, the rescuer receives immediate correction without interrupting compressions. On compatible devices such as the X Series, the system adds the See-Thru CPR® feature, which filters compression artefact to analyse the cardiac rhythm without pauses. As it is a pre-connected single-piece electrode, application time is reduced to a minimum: remove the protective cover, place the assembly on the chest following the anatomical diagrams on the packaging, and the device is ready for analysis, defibrillation and monitoring.
3. Technical Specifications
| Manufacturer reference | 8900-0800-01 (ZOLL Medical Corporation) |
| SKU Cahnos | 1351002 |
| Electrode type | Adult multifunction electrode, single-piece (anterior + posterior) with CPR sensor |
| Presentation | 1 pair (1 single piece with both electrodes) |
| Population | Adult patients and children over 8 years (approx. from 55 lb / 25 kg) |
| Technology | Real CPR Help® (compression rate and depth), adaptive metronome and See-Thru CPR® on compatible equipment |
| Compatibility | ZOLL AED Plus®, AED Pro®, AED 3®, AED 3 BLS®, R Series®, X Series®, Propaq MD®; M Series® and E Series® (with CPR connector 8000-0370 on some models) |
| Rescue kit included | Gloves, barrier face mask, scissors, razor, wet wipe and dry wipe |
| Shelf life | Up to 5 years from date of manufacture (the longest on the market for disposable electrodes) |
| Storage | Long-lasting protective packaging type “armor pack”, suitable for defibrillator soft case |
| Use | Single-use, disposable, non-sterile |
| Regulatory registration | GUDID/FDA: 00847946000189 (version/model 8900-0800-01) |
4. Equivalences and Cross-References
There is no official equivalence table validated by ZOLL that would allow replacing ref. 8900-0800-01 with electrodes from other manufacturers: the CPR-D connector is a ZOLL proprietary system and compatibility must always be confirmed against the official technical data sheet and IFU. Therefore, any comparison with other brands must be understood as comparable at category level, not 1:1 interchangeable (connector, geometry, sensor and algorithm differ). Within the ZOLL family itself, the related references are:
| Reference | Product | Related items |
| 8900-0801 | Stat Padz II adult electrode (1 pair) for AED Plus/PRO | Alternative without Real CPR Help sensor |
| 8900-0802-01 | Stat Padz II adult electrode (box of 12 pairs) | Same family, multipack format |
| 8900-0810-01 | Pedi Padz II paediatric electrode (1 pair) | Complementary, population < 25 kg |
| 8900-000260 | CPR Uni-padz universal adult/paediatric for AED 3 | CPR family, AED 3 connector |
| 8900-0804-01 | CPR-D•PADZ training electrodes for TRAINER 2 | Exclusive use in training |
As for other manufacturers with CPR sensor electrodes (e.g. PRIMEDIC for HeartSave), the comparison is functional by category: same clinical concept (compression feedback), but different connector, device and specifications. Any cross-reference must be confirmed with the technical department before use in tenders.
5. Selection tips and variants of interest
- If your AED is a ZOLL AED Plus or AED Pro and you want real-time CPR guidance, ref. 8900-0800-01 is the indicated replacement: it is the original electrode with Real CPR Help.
- If you do not need a CPR sensor (for example, public access programmes with prior training), Stat Padz II (8900-0801) may be considered, at a lower cost per pair.
- For paediatric patients (< 8 years / < 25 kg), always use Pedi Padz II (8900-0810-01): it automatically switches the paediatric energy levels on AED Plus/AED Pro.
- On AED 3 devices, the correct replacement is the CPR Uni-padz universal (8900-000260), not this electrode.
- Manage stock rotation by expiry date: the service life of up to 5 years reduces the total cost of ownership, but the date printed on the packaging must be checked and the electrode replaced after use or expiry.
- Consult the Cahnos technical department to confirm exact compatibility with your defibrillator model before formalising large-volume orders or tenders.





Reviews
There are no reviews yet.