Description
1. Commercial Introduction
The radiotransparent foam electrode for neonatal monitoring RT 22 LWF (SKU 15081) is a highly reliable disposable consumable, specifically designed for electrocardiographic recording and continuous monitoring of newborns and premature infants. Its Ø 30 mm diameter, medical foam construction and radiotransparent nature make it the ideal choice for neonatal intensive care units, neonatology services, neonatal transport and incubators, as well as any area where patient monitoring is required without interfering with imaging tests. It is supplied in a bag of 3 units, with a minimum sale of a box of 300 units, intended for continuous consumption by hospital services and procurement centres.
2. Technical Explanation
These electrodes act as an interface between the neonate’s skin and the bedside monitor: the foam backing with medical-grade adhesive ensures a gentle yet firm attachment to the newborn’s delicate skin, while the conductive sensor element (carbon/Ag-AgCl type on solid gel, depending on batch) guarantees stable, low-impedance signal transmission for a clean, continuous ECG trace. The integrated 60 cm cable terminates in a Ø 4 mm female connector (4 mm socket/banana type), compatible with the lead wires of most ECG monitors and electrocardiographs with a 4 mm connection standard. Its radiotransparent nature allows the electrodes to remain in place during X-rays, radioscopy and other imaging examinations without generating artefacts or interruptions in monitoring, a critical value in neonatal patients requiring continuous cardiac monitoring during the examination. It is a single-use product, latex-free.
3. Technical Specifications
| Parameter | Specification |
| Reference / SKU | 15081 |
| Model / family | RT 22 LWF |
| Type | Radiolucent foam electrode for neonatal monitoring |
| Material | Foam (medical foam) and radiolucent material |
| Diameter | Ø 30 mm |
| Cable | 60 cm, pre-wired |
| Connection | 4 mm female connector (4 mm socket) |
| Radiotransparency | Yes, suitable for X-ray and imaging examinations |
| Application | Neonatal ECG monitoring, neonatal ICUs, incubators |
| Use | Single-use (disposable), latex-free |
| Presentation | Bag of 3 units |
| Minimum sales unit | Box of 300 units |
Note: the connection values (4 mm female connector) and presentation (3 units/bag, 300 units/box) are copied literally from the distributor’s technical documentation; confirm with the technical data sheet of the supplied batch. Radiotransparency refers to use with planar imaging (X-rays); verify compatibility in MRI in the equipment manual.
4. Equivalences and Cross-References
This reference belongs to the category of pre-wired, radiotransparent neonatal monitoring electrodes with 4 mm connection. After verifying manufacturer catalogues, authorised distribution and regulatory databases, the following cross-references with confirmed codes in public sources have been identified. Any comparison between brands should be understood as comparable by category (not 1:1 interchangeable): check one by one the backing material, diameter, connector type and monitor lead wire before substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Dormo (distributed by Telic Group) | Dormo KFS-150 ECG electrode, Ø 30 mm, pre-wired | KFS-150 (SKU TEK27) | Comparable by category (not interchangeable 1:1) | Code confirmed in the distributor’s catalogue: foam backing, solid gel, Ø 30 mm, 60 cm cable, Ø 4 mm female connector, bag of 3 units. Key difference: not radiotransparent according to technical data sheet and box of 99 units. Verify need for radiotransparency before substitution. |
| FIAB Group | Pre-wired neonatal foam series with 4 mm socket, oval shape 23×30 mm, radiolucent | F9053NRM (35 cm) / F9053NRM/80 (80 cm) | Comparable by category (not interchangeable 1:1) | Code confirmed in the manufacturer’s official catalogue: foam backing, SSC sensor, 4 mm socket, neonatal and radiolucent. Differences: oval geometry 23×30 mm and cable length of 35 or 80 cm versus round Ø 30 mm and 60 cm cable. Verify monitor connector and lead wire. |
| Lessa (AB Médica) | Neonatal RX single-use ECG electrode, radiotransparent carbon version | 9909957 | Comparable by category (not interchangeable 1:1) | Code confirmed in the manufacturer’s catalogue: radiotransparent carbon, 4 mm female connector, 0.35 m cable, oval shape 23×20 mm, presentation of 150 units (5 bags of 30). Differences: non-woven fabric backing versus foam and shorter cable. Verify backing material and cable length before substitution. |
There is no equivalence table validated by the manufacturer that authorises the substitution of original electrodes with third-party patches: the connector, lead wire and patch size are specific to each monitoring platform. Any substitution must be validated against the technical data sheet and instructions for use of the monitor and the electrode; consult with the technical department of Cahnos before use in tenders.
5. Selection tips and variants of interest
- Verify the connector type of your monitor: this reference uses a 4 mm female connector. If your lead wire uses a 1.5 mm DIN socket (1.55 mm), request the RT 22 LWS variant of Ø 30 mm with 1.55 mm connection (SKU 15082) from the same family.
- Choose the diameter according to weight and thoracic surface area: for very low birth weight or extremely premature neonates, the RT 22 LWF version of Ø 22 mm with the same 4 mm connection (SKU 15079) may be considered, which reduces the adhesion area on very delicate skin; a Ø 22 mm version with 1.55 mm connection (SKU 15080) is also available.
- Radiotransparency: if the patient may require X-ray or imaging control during monitoring, this version avoids artefacts without removing the electrode. Remember to verify compatibility in MRI in the equipment manual.
- Single-use and storage: disposable, single-use per patient; store in a dry place and respect the expiry date on the packaging to avoid compromising the conductivity of the adhesive.
- Institutional orders: the minimum box of 300 units is intended for the supply of neonatology and ICU services; for tenders and bids, contact the technical-commercial department of Cahnos to confirm compatibility with your monitor fleet before placing the order.





Reviews