Description
1. Commercial Introduction
Keep your Philips/Laerdal family defibrillator always ready to also treat the smallest patients. This pair of standard paediatric defibrillator electrodes with internal cable (reference Cahnos F7970P) is the replacement consumable indicated for paediatric defibrillation in equipment that works with Laerdal Medical Snap-connection internal cables. It is sold as a pair (2 units) and is ready to be integrated into emergency cardiopulmonary resuscitation protocols, paediatric intensive care units (PICU), ambulances, health centres and heart-safe spaces.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface element between the defibrillator and the patient: through them the equipment analyses the cardiac rhythm, delivers the transthoracic shock and, in many models, allows emergency ECG monitoring. In paediatric patients (under 8 years or weighing less than 25 kg) it is essential to attenuate the delivered energy to avoid myocardial injury; therefore this electrode features a reduced active surface of 40 cm² per pad and must be used with the equipment’s paediatric mode switching or with the reduced energy setting (50–100 J) indicated in the defibrillator manual.
This standard with internal cable variant does not include an external cable: the pad attaches directly via a Snap-type safety anti-shock connector (clip) onto the equipment’s internal cable, ensuring a firm and quick connection in an emergency. The recommended placement is anterolateral (anteroapical position), so that both pads do not come into contact with each other on the infant’s chest. They are single-use and disposable: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the packaging.
3. Technical Specifications
| Parameter | Specification |
| Reference Cahnos (SKU) | F7970P |
| Product type | Pair of paediatric multifunction defibrillator electrodes, standard, with internal cable and Snap connector |
| Target population | Paediatric (< 8 years / < 25 kg) |
| Total surface (per electrode) | 75 cm² (paediatric series) |
| Active surface (per electrode) | 40 cm² (paediatric series) |
| Adhesive ring width | 1 cm |
| Supported shocks | 50 shocks (paediatric energy 50–100 J; verify according to the equipment’s instructions) |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (FOAM) 1 mm thick |
| Connection type | Snap-type safety anti-shock connector (clip), on internal cable |
| ECG monitoring | Up to 24 h |
| Use | Single-use, disposable, non-sterile |
| Composition | Latex-free and phthalate-free |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10 |
| Presentation | Price per pair (2 units); 5 pairs per box (paediatric series) |
| Primary packaging | 1 pair in heat-sealed polyethylene and aluminium bag, with laser pre-cut and opening notch |
| Shelf life | Approx. 30 months from the date of production; expiry indicated on the packaging |
| Storage | Dry place, between +5 °C and +35 °C; operation between 0 °C and +50 °C |
Compatibility with cables and equipment (according to the distributor’s commercial documentation)
| Laerdal Medical cable | Cited compatible equipment |
| Ref. 945004 | Supplied with Philips MRx, FR (series) and XL defibrillators |
| Ref. 920601 / Ref. 920602 | Supplied with the HeartStart 3000 defibrillator |
Note: codes 945004, 920601 and 920602 correspond to internal cables from the Laerdal/Philips family cited in the distributor’s documentation and in this same data sheet for compatibility identification purposes; they are not electrode manufacturer pad codes. Always confirm the cable and the exact model of your equipment before clinical use.
4. Equivalences and Cross-References
Reference F7970P is the Cahnos distribution code for this compatible electrode; it is not an official reference from the equipment manufacturer. Codes 920601, 920620, 920602 and 945004 appear in the distributor’s commercial documentation as internal cable references from the Laerdal/Philips family: they could not be verified as pad codes in public sources (GUDID/EUDAMED with no results for 920601 and 920620), so their correspondence must be confirmed with the technical department before use in tenders. Comparisons with other brands are understood at category level: the connector, analysis algorithm and energy management are proprietary to each device.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Philips | Infant Pads with barrel connector – original paediatric electrodes for HeartStart MRx/XL/XL+ and CodeMaster family | M3504A (also 989803106951) | Comparable by category (not interchangeable 1:1) | Factory original with conductive surface of 75 cm² and 60 cm cable; uses barrel connector (not Snap) and requires cable M3507A/M3508A. Code confirmed in GUDID/FDA (DI 00884838022034). |
| Philips | Adult/Child Pads with barrel connector – original adult/child electrodes (≥ 10 kg) | M3501A (also 989803106921) | Comparable by category (not interchangeable 1:1) | Original adult/child with barrel connector that also covers the paediatric range of 10–25 kg; verified in Philips technical documentation. |
| ZOLL Medical | Pedi-Padz II – original paediatric electrodes for AED Plus / AED Pro | 8900-0810 / 8900-0810-01 | Comparable by category (not interchangeable 1:1) | Preconnected (without Snap connector), conductive hydrogel, paediatric energy 50/70/85 J adjusted by the device; not suitable for Philips/Laerdal equipment due to proprietary connector. Code confirmed in technical data sheet and GUDID. |
There is no equivalence table validated by the manufacturer that authorises the replacement of the original electrodes of the Laerdal/Philips family with third-party pads: the connector, the analysis algorithm and the energy management are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator; consult with the Cahnos technical department before use in tenders. Within the Cahnos catalogue there are other references in the same family (standard paediatric with internal cable and Snap connection) intended for equipment from other manufacturers, not interchangeable with each other: F7950P (Philips), F7972P (Marquette GE / Esaote) and F7962P (Marquette GE).
5. Selection tips and variants of interest
- Confirm the cable and the equipment model: verify that your defibrillator uses an internal Laerdal Medical cable with Snap connector (cited family: HeartStart 3000 with cables 920601/920602; MRx, FR and XL with cable 945004) and that the clip fits correctly before clinical use.
- Do not confuse the paediatric and adult versions: this pair is for patients under 8 years of age or under 25 kg; the adult version of the same connector family is supplied under reference F7970.
- Paediatric mode: make sure the equipment switches to paediatric mode or energy (reduced energy setting 50–100 J) according to the defibrillator manual; on manually adjustable models, always select it before the shock.
- Check the expiry date: check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; expired electrodes or those with damaged packaging must not be used (the gel may lose conductivity).
- Plan your replenishment: as this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date. For volume orders or tenders, contact the Cahnos technical department stating the exact model and serial number of your equipment.