Pair of adult standard defibrillator electrodes with internal cable (preconnected) – Replacement compatible with Nihon Kohden Cardiolife TEC-8250 and TEC-8251 · Ref. F7963

27,25 €

Pair of defibrillator electrodes adult standard with internal cable (preconnected), reference Cahnos F7963, replacement compatible with the defibrillator-monitors Nihon Kohden Cardiolife TEC-8250 and TEC-8251 with L200 cable (200 cm). Disposable single-use multifunction pads for adult patients (> 8 years / > 25 kg): defibrillation, synchronised cardioversion and ECG monitoring (max. 24 h), with low-impedance conductive adhesive gel, metallic foil and 1 mm medical foam backing. Active surface area of 95 cm² per electrode and up to 50 shocks (50–360 J). Direct connection to the equipment socket, with no loose cables during resuscitation. Latex-free and phthalate-free, CE medical device class IIb; price per pair (2 units). Always check the connector fit and the packaging expiry before clinical use.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7963

Description

1. Commercial Introduction

Keep your Nihon Kohden defibrillator-monitor always ready to act with this pair of standard adult defibrillator electrodes with internal cable (reference Cahnos F7963). It is the replacement consumable indicated for the equipment of the Cardiolife TEC-8250 and TEC-8251 series with model L200 cable (200 cm), the manufacturer’s pre-connected connection configuration for emergency environments, ambulances, hospitals and cardiac-protected spaces.

Its configuration with integrated internal cable provides a direct and stable connection to the equipment’s electrode socket: no loose cables during the procedure and with the connector protected until the moment of assistance. It is sold as a pair (2 units) in an individual heat-sealed package and is ready to be integrated into the cardiopulmonary resuscitation protocols of any service equipped with Nihon Kohden. Available with immediate dispatch from Cahnos and specialised technical support for compatibility verification by model and connector.

2. Technical explanation of the equipment and procedure

Multifunction defibrillation electrodes are the interface element between the defibrillator and the patient: through them the equipment analyses the cardiac rhythm, delivers the biphasic transthoracic shock, allows synchronised cardioversion and monitors the emergency electrocardiogram. This pair is indicated for adult patients (over 8 years old or weighing more than 25 kg) and connects via its integrated internal cable to the safety anti-shock connector of the TEC-8250 and TEC-8251 equipment.

The low-impedance conductive adhesive gel ensures homogeneous contact with the skin, low interface resistance and optimal transmission of the shock energy; the inner metal foil distributes the current uniformly and the 1 mm thick medical foam (FOAM) support adapts to the contours of the chest, minimising the risk of burns. The recommended placement is anterolateral (sternum-apex), following the anatomical diagrams printed on the packaging and without both patches coming into contact with each other. They are single-use and disposable: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the sachet.

3. Technical Specifications

3.1 Product identification

Parameter Specification
Reference Cahnos (SKU) F7963
Product type Pair of adult multifunction defibrillator electrodes, standard, with internal cable (pre-connected)
Compatible equipment brand Nihon Kohden – Cardiolife TEC-8250 and TEC-8251
Cable / connection Integrated internal cable (pre-connected), model L200 – length 200 cm
Presentation Price per pair (2 units); 1 pair in heat-sealed packaging; 10 pairs per box in the adult series

3.2 Compatible models

Equipment model Cable / connection
Nihon Kohden Cardiolife TEC-8250 Internal cable L200 (200 cm)
Nihon Kohden Cardiolife TEC-8251 Internal cable L200 (200 cm)

3.3 Technical features

Parameter Specification
Patient type Adult (older than 8 years / more than 25 kg)
Cable configuration Integrated / pre-connected internal cable (direct connection to the equipment socket), L200
Total surface (per electrode) 148 cm²
Active surface (per electrode) 95 cm²
Adhesive ring width 1 cm
Supported shocks Up to 50 shocks (50 to 360 J in adult configuration)
Functions External defibrillation, synchronised cardioversion and ECG monitoring
ECG monitoring Up to 24 h
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material Medical foam (FOAM) 1 mm thick
Connection type Safety anti-shock connector, with internal cable
Use Single-use, disposable, non-sterile
Latex / phthalates Latex-free and phthalate-free
Regulatory classification Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)
Reference standards ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10
Shelf life Approx. 30 months from the date of manufacture; expiry date indicated on the packaging
Storage Dry place, between +5 °C and +35 °C; operating from 0 °C to +50 °C

Technical note: the values for active surface (95 cm²), total area (148 cm²), shocks (50–360 J) and adhesive ring (1 cm) correspond to the standard adult electrode series with internal cable of this product family; confirm them with the technical data sheet of the supplied batch and the equipment manual before use in tenders. The L200 cable (200 cm) is the pre-connected configuration of this reference for the TEC-8250 and TEC-8251 models.

4. Equivalences and Cross-References

Reference F7963 is the Cahnos distribution code for this standard adult electrode with internal cable for the Nihon Kohden TEC-8250 / TEC-8251 platform; it is not an official reference of the equipment manufacturer. The connector, analysis algorithm and energy management are proprietary to each defibrillator, so equivalences with other brands are considered comparable only at category level and not interchangeable 1:1. The following cross-references have a confirmed code in the official manufacturer-technical distributor catalogue, IFU or regulatory database:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
AB Medica Group (Lessa) DEFI-PAD adult compatible with Nihon Kohden TEC-8250 / TEC-8251 99.835.34 Comparable by category (not interchangeable 1:1) Code confirmed in the official defibrillation pads catalogue of AB Medica Group (Lessa) for the TEC-8250 and TEC-8251 models; same clinical platform and adult profile. Verify connector (equipment JC-755V cable), cable configuration and measurements before replacement.
Nihon Kohden (original equipment replacement) Disposable adult/child/infant pad (factory original) P-740K Comparable by category (not interchangeable 1:1) Factory original with 1.5 m cable; reference confirmed in the manufacturer’s official IFU and authorised distributors. Covers AED-2100K/2150K/2151K/2152K, AED-3100, EMS-1052 and the TEC-5500, TEC-5600, TEC-7600, TEC-7700 and TEC-8300 series; not verified for the TEC-8250/8251 models with JC-755V cable.
Nissha Medical Technologies (HeartSync) T100AC-NIHONKOHDEN – compatible multifunction pads Nihon Kohden 6600265H Comparable by category (not interchangeable 1:1) Code confirmed in the manufacturer’s official catalogue: 2 m leads-in cable (inside the package) and radiolucent construction, for the TEC-5500, TEC-5600, TEC-7600, TEC-7700 and TEC-8300 series. Verify connector and cable (JC-755V / K342A depending on series) before replacement; not listed for TEC-8250/8251.
ZOLL Medical Stat-Padz® II – adult multifunction electrodes (AED Plus / AED Pro) 8900-0801-01 Comparable by category (not interchangeable 1:1) Factory original pre-connected with polymer conductive gel for the brand’s AEDs; code confirmed on the manufacturer’s website and GUDID. Proprietary ZOLL connector, not suitable for the electrode socket of Nihon Kohden equipment.

There is no equivalence table validated by the manufacturer (Nihon Kohden) that authorises the replacement of original electrodes with third-party patches: the connector, analysis algorithm and energy management are proprietary. Any replacement must be validated against the defibrillator’s technical data sheet and IFU, checking one by one the equipment connector, energy range, target population and package expiry. Consult the Cahnos technical department before use in tenders.

5. Selection tips and variants of interest

Confirm the equipment model: verify that your defibrillator is a Nihon Kohden Cardiolife TEC-8250 or TEC-8251 and that the L200 internal cable connector fits correctly into the equipment’s electrode socket before clinical use; if in doubt, contact the Cahnos technical department stating the model and serial number.

Do not confuse versions: this pair is for adult patients (over 8 years old or over 25 kg). For the paediatric population of the same connector family, references F7961P (internal cable) and F7961PW (external cable) are available.

Internal cable versus other configurations: the configuration with an integrated internal cable provides a direct connection with no loose cables during resuscitation. If your workflow requires leaving the connector accessible without opening the pouch, consider the external cable variant from the same Nihon Kohden connector family (F7961W for the TEC-2200/2300/5500 series with JC-765V cable); for imaging procedures (radiology, haemodynamics) there is a radiolucent version with internal cable F7761.

Storage and expiry: always check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; do not use expired electrodes or those with a damaged pouch, as the gel may lose conductivity.

Plan your replenishment: as this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date (FIFO method). For volume orders or tenders, contact the technical-commercial department at Cahnos stating the exact model and serial number of your defibrillator.

Additional information

Reference

F7963

Compatible equipment brand

Nihon Kohden

Compatibility

Cardiolife TEC-8250, TEC-8251

Patient type

Adult (older than 8 years / more than 25 kg)

Cable configuration

Integrated internal cable (pre-connected), L200 – 200 cm

Total surface

148 cm² per electrode

Active surface

95 cm² per electrode

Adhesive ring width

1 cm

Supported shocks

Up to 50 shocks (50 to 360 J)

Functions

External defibrillation, synchronised cardioversion and ECG monitoring

ECG monitoring

Up to 24 h

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

Backing material

1 mm medical foam (FOAM)

Connection type

Safety anti-shock connector with internal cable

Use

Single-use, disposable, non-sterile

Latex, phthalates

Latex-free and phthalate-free

Regulatory classification

Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10

Shelf life

Approx. 30 months from date of manufacture

Storage

Dry place, between +5 °C and +35 °C; operating from 0 °C to +50 °C

Presentation

Price per pair (2 units); 10 pairs per box in the adult series