Standard paediatric defibrillator electrode with internal cable for Nihon Kohden Cardiolife TEC-2200, TEC-2300 and TEC-5500 (pair) – Ref. F7961P

32,25 €

Pair of standard paediatric defibrillator electrodes with internal cable (reference Cahnos F7961P), compatible replacement for Nihon Kohden defibrillators of the Cardiolife TEC-2200, TEC-2300 and TEC-5500 series with JC-765V cable. Designed for patients under 8 years of age or weighing less than 25 kg, with a reduced active surface of 40 cm² per electrode, low-impedance conductive adhesive gel, metal foil and 1 mm medical foam (FOAM) backing. Up to 50 discharges in paediatric configuration, ECG monitoring for up to 24 h and safety anti-shock connector. Single-use medical device, latex-free and phthalate-free, class IIb. Sold as a pair with immediate dispatch and technical support for compatibility verification by model and connector.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7961P

Description

1. Commercial Introduction

Ensure safe and effective cardiopulmonary resuscitation in the smallest patients with this pair of standard paediatric defibrillator electrodes with internal cable (reference Cahnos F7961P), a replacement consumable compatible with Nihon Kohden defibrillators from the Cardiolife TEC-2200, TEC-2300 and TEC-5500 series with JC-765V cable. It is the ideal solution for emergency departments, paediatric intensive care units (PICU), ambulances and any clinical setting that cares for children: a single pair of disposable pads keeps the equipment ready to act in cardiorespiratory arrest. Available with immediate dispatch from Cahnos and specialised technical support for compatibility verification by model and connector.

2. Technical explanation of the equipment and procedure

Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the device analyses the cardiac rhythm, delivers the transthoracic shock and monitors the emergency electrocardiogram. In paediatric patients (under 8 years of age or weighing less than 25 kg) it is essential to attenuate the delivered energy to avoid myocardial injury; therefore this electrode incorporates a reduced active surface area of 40 cm² per electrode and must be used with the device’s paediatric mode switching or with the reduced energy configuration indicated in the defibrillator manual.

The integrated internal cable configuration provides a stable, direct connection to the device’s electrode socket, with no loose cables during resuscitation. The low-impedance conductive adhesive gel ensures stable adhesion and a reliable signal, while the metal foil and 1 mm medical foam (FOAM) guarantee a uniform distribution of current over the infant chest. The recommended placement is anterolateral (sternum-apex position), maintaining a minimum separation between the two pads. They are single-use: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the packaging.

3. Technical specifications and compatibility

Reference Cahnos (SKU) F7961P
Brand / compatible equipment Nihon Kohden – Cardiolife TEC-2200 Series, TEC-2300 Series and TEC-5500 Series
Cable type Internal cable JC-765V (direct connection to the electrode socket)
Product type Standard multifunction paediatric electrode pair with internal cable
Presentation Price per pair (2 units); 5 pairs per box (paediatric series)
Parameter Specification
Target population Paediatric (< 8 years / < 25 kg)
Cable configuration Integrated internal cable (direct connection to the equipment electrode socket)
Total surface (per electrode) 75 cm²
Active surface (per electrode) 40 cm²
Adhesive ring width 1 cm
Supported shocks Up to 50 discharges (energy 50–100 J in paediatric configuration; verify according to the device indications)
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material Medical foam (FOAM) 1 mm thick
Connection type Safety anti-shock connector with internal cable
ECG monitoring Up to 24 h
Use Single-use, disposable, non-sterile; latex-free and phthalate-free
Regulatory classification Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)
Reference standards ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10
Shelf life Approx. 30 months from the date of production; expiry indicated on the packaging
Storage Dry place, between +5 °C and +35 °C

Note: the values for active surface area (40 cm²), total area (75 cm²), discharges (50–100 J) and adhesive ring (1 cm) correspond to the standard paediatric electrode series with internal cable in this product family; confirm them with the technical data sheet of the supplied batch and the device manual before use in tendering.

Compatibility with defibrillators

Equipment brand Compatible models Required cable
Nihon Kohden Cardiolife TEC-2200 Series Internal cable JC-765V
Nihon Kohden Cardiolife TEC-2300 Series Internal cable JC-765V
Nihon Kohden Cardiolife TEC-5500 Series Internal cable JC-765V

Note: always verify the correct fit of the connector in the device’s electrode socket before clinical use.

4. Equivalences and Cross-References

Reference F7961P is the Cahnos distribution code for this electrode compatible with Nihon Kohden; it is not an official reference of the equipment manufacturer. The connector and energy management of the Cardiolife TEC defibrillators are proprietary to Nihon Kohden, so equivalences with other brands are comparable only at category level and are not interchangeable 1:1. After verifying authorised distribution catalogues, the following cross-references with code confirmed in public sources have been identified. In no case is there an official equivalence table validated by the manufacturer for this reference.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Nihon Kohden Disposable defibrillation electrodes adult/child/infant (original P-740K) P-740K Comparable by category (not interchangeable 1:1) Factory original with 1.5 m cable, for adults and children; confirmed in authorised distributors of original spare parts. Covers AED-2100, AED-3100 and TEC-5600, TEC-7700 and TEC-8300 families; not verified for the TEC-2200/2300 series with internal JC-765V cable. Connector and labelling proprietary to Nihon Kohden; verify paediatric size and fit before replacement.
Nihon Kohden Disposable AED electrodes adult/child/infant (original P-711) P-711 (order code H329) Comparable by category (not interchangeable 1:1) Factory original with 1.5 m cable, for adult, child and infant; confirmed in authorised distributors. Aimed at the Cardiolife AED and TEC-8300K families; not verified for the TEC-2200/2300/5500 series with JC-765V cable. Verify compatibility before replacement.

No verifiable original Nihon Kohden paediatric electrode specific to the TEC-2200/2300 series with internal JC-765V cable has been found in public sources; the manufacturer publishes electrodes with paediatric capability aimed at its AED and TEC-8300 families (P-711/H329, P-713/H330 for infant and P-740K). There is no equivalence table validated by the manufacturer that authorises the replacement of original electrodes with third-party pads: the connector and energy management of each defibrillator are proprietary. Any replacement must be validated against the defibrillator’s technical data sheet and instructions for use; consult the Cahnos technical department before use in tendering.

5. Selection tips and variants of interest

Confirm the equipment model: verify that your defibrillator is a Nihon Kohden Cardiolife TEC-2200, TEC-2300 or TEC-5500 and that the internal cable connector JC-765V fits correctly into the electrode socket of the equipment before clinical use; if in doubt, contact the technical department of Cahnos stating the model and serial number.

Do not confuse the paediatric and adult versions: this pair is for patients under 8 years of age or weighing less than 25 kg. For adult patients of the same connector family, Nihon Kohden offers the standard adult version with internal cable of the same series.

Energy in paediatric mode: always select the paediatric or reduced energy setting (50–100 J) indicated in the equipment manual; do not manually modify energy levels without protocol indication.

Variants of the same Cahnos family: version with external cable for Nihon Kohden (F7961PW, for TEC-5500, TEC-5600 and TEC-7600), standard multi-brand version with internal cable (F7955P) or with external cable (F7955PW), and radiotransparent version with internal cable (F7755P) if X-rays or CT scans are anticipated during care. In the internal cable family for other equipment, not interchangeable with each other due to proprietary connector: F7981P (GE Responder), F7986P (Mediana D500), F7985P (Instramed CardioMax) and F7951P (ZOLL).

Storage and expiry: always check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; expired electrodes or those with damaged packaging must not be used because the gel may lose conductivity. As this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date. For volume orders or tenders, contact the technical department of Cahnos stating the exact model and serial number of your equipment.

Additional information

Compatibility

Nihon Kohden – Cardiolife TEC-2200, TEC-2300 and TEC-5500

Product type

Standard paediatric defibrillator electrode pair with internal cable, multifunction

Patient type

Paediatric (< 8 years / < 25 kg)

Cable type

Internal cable JC-765V (direct connection to the electrode socket)

Total surface per electrode

75 cm²

Active surface per electrode

40 cm²

Adhesive ring width

1 cm

Supported shocks

Up to 50 (50–100 J in paediatric configuration)

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

Backing material

1 mm medical foam (FOAM)

Connection type

Safety anti-shock connector with internal cable

ECG monitoring

Up to 24 h

Use

Single-use, disposable, non-sterile

Latex-free and phthalate-free

Yes

Regulatory classification

Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10

Shelf life

Approx. 30 months from production; expiry on the packaging

Storage

Dry place, between +5 °C and +35 °C

Presentation

Price per pair (2 units); 5 pairs per box (paediatric series)