Description
1. Commercial Introduction
Ensure safe and effective cardiopulmonary resuscitation in the smallest patients with this pair of standard paediatric defibrillator electrodes with internal cable (reference Cahnos F7951P), a replacement consumable compatible with ZOLL Medical defibrillators and monitors from the PD, E, M and R series. It is the ideal solution for emergency services, paediatric intensive care units (PICU), ambulances, medical transport and any cardioprotected location equipped with ZOLL that cares for children: a single pair of disposable pads keeps the equipment ready to act in cardiorespiratory arrest. Available with immediate dispatch from Cahnos and specialised technical support for compatibility verification by model and connector.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface between the defibrillator and the patient: through them the equipment analyses the cardiac rhythm, delivers the transthoracic shock and, in many models, allows emergency ECG monitoring. In paediatric patients (under 8 years of age or weighing less than 25 kg) it is essential to attenuate the delivered energy to avoid myocardial injury; therefore this electrode has a reduced active surface of 40 cm² per electrode and must be used with the equipment’s paediatric mode switching or with the reduced energy setting (50–100 J) indicated in the defibrillator manual.
The integrated internal cable configuration provides a stable and direct connection to the equipment’s electrode socket, without loose cables during resuscitation. The recommended placement is anterolateral (sternum-apex position), maintaining a minimum separation between both pads on the child’s chest. The low-impedance conductive adhesive gel ensures stable adhesion and a reliable signal, while the metal foil and medical foam (FOAM) of 1 mm thickness guarantee a uniform distribution of the current. They are single-use: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the packaging.
3. Technical Specifications
Standard multifunction paediatric electrode from the paediatric defibrillator pad series, in its variant with integrated internal cable of 100 cm.
| Field | Specification |
|---|---|
| Reference Cahnos (SKU) | F7951P |
| Product type | Pair of standard multifunction paediatric defibrillator electrodes with internal cable (100 cm) |
| Indicated population | Children under 8 years or weighing less than 25 kg |
| Functions | External defibrillation, synchronised cardioversion and ECG monitoring (max. 24 h) |
| Supported shocks | 50 to 100 J (paediatric series) |
| Total surface (per electrode) | 75 cm² |
| Active area (per electrode) | 40 cm² |
| Adhesive ring width | 0.7 cm |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (FOAM) 1 mm thick |
| Connection type | Safety anti-shock connector, with integrated internal cable |
| Use | Single-use, disposable; latex-free and phthalate-free |
| Presentation | 1 pair in heat-sealed polyethylene and aluminium pouch; 5 pairs per box (paediatric series) |
| Shelf life | Approx. 30 months from date of manufacture (check printed expiry date) |
| Conditions of use and storage | Operating temperature from 0 °C to +50 °C; store in a dry place between +5 °C and +35 °C |
| Classification | Class IIb medical device (Directive 93/42/EEC and amendments; EU Regulation 2017/745) |
| Regulatory standard | ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993-10 |
Compatibility with defibrillators and monitors
| Equipment manufacturer | Compatible models |
|---|---|
| ZOLL Medical | PD 1200, PD 1400, PD 1600, PD 1700, PD 2000 |
| ZOLL Medical | E Series, M Series, R Series |
Technical note: always verify the correct insertion of the connector into the equipment socket before clinical use. The values for active surface (40 cm²), total area (75 cm²), shocks (50–100 J) and adhesive ring (0.7 cm) correspond to the standard paediatric electrode series with internal cable of this product family; confirm them with the technical data sheet of the supplied batch and the equipment manual before use in tendering.
4. Equivalences and Cross-References
This electrode (SKU F7951P) is a consumable compatible with the aforementioned ZOLL equipment, not an original factory spare part. The correspondence with references from other manufacturers is as follows; any comparison between brands must be understood as comparable at category level, not interchangeable 1:1, verifying one by one the equipment connector, paediatric energy range and algorithm before any replacement.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| ZOLL Medical | Pedi·Padz II — multifunction paediatric electrodes (original equipment) | 8900-0810-01 | Comparable by category (not interchangeable 1:1) | Factory original pre-connected for AED Plus and AED Pro; in M/E/R Series it is used in manual mode. Hydrogel with tin conductive element, paediatric range 0–8 years / <25 kg with levels of 50/70/85 J. Code confirmed in the official ZOLL store and in GUDID (UDI 00847946001438). |
| Leonhard Lang | Skintact® Easibeat paediatric multifunction (<25 kg) — ZOLL connector | DF30G | Comparable by category (not interchangeable 1:1) | Multifunction paediatric electrode for defibrillation, pacing and monitoring with ZOLL connector (M-, E-, R- and X-Series); cable of 1.2 m. Code confirmed in the official Leonhard Lang catalogue and in authorised distributors. |
| Stryker / Physio-Control | Infant/Child Reduced Energy Defibrillation Electrodes (for LIFEPAK with pink connector) | 11101-000016 | Comparable by category (not interchangeable 1:1) | Paediatric electrode with energy reduction (200 J → ≈50 J) for the LIFEPAK 500, 1000, EXPRESS and CR Plus AEDs; proprietary QUIK-COMBO connector and algorithm, not suitable for ZOLL equipment. Code confirmed in the official Stryker store and in GUDID (UDI 00721902629013). |
| Defibtech | Lifeline AED Child / Pediatric Electrode Pads | DDP-200P | Comparable by category (not interchangeable 1:1) | Paediatric electrodes with integrated energy attenuation for children under 8 years of age or less than 25 kg; connector, algorithm and electronics proprietary to Lifeline equipment. GUDID/FDA UDI-DI registration 00815098020430. |
There is no equivalence table validated by ZOLL Medical that authorises the replacement of the original Pedi·Padz electrodes with third-party pads: the connector, the analysis algorithm and the energy management are proprietary. Any replacement must be validated against the technical data sheet and IFU of the defibrillator. Consult the technical department of Cahnos before use in tenders.
5. Selection tips and variants of interest
Confirm the model and connector of the device: this pair corresponds to the ZOLL defibrillators and monitors PD 1200, PD 1400, PD 1600, PD 1700, PD 2000, E Series, M Series and R Series. Check the reference and expiry date printed on the packaging before replacement; do not use an expired electrode or reuse a pair after a procedure.
Choose the variant according to your workflow: the internal cable of this model provides a clean and robust connection during resuscitation; if you prefer to leave the device pre-connected and ready in seconds, you have the reference F7951PW (same standard paediatric series with external cable). For an image requirement without artefacts in X-rays or CT scans, consider the radiolucent series F7751P (internal cable) or F7751PW (external cable), with the same ZOLL compatibility. The adult version of this same family is the F7951W.
Paediatric mode: ensure that the device switches to paediatric mode or energy (reduced energy setting 50–100 J) according to the defibrillator manual; on manual adjustment models (M/E/R Series), always select it before the shock.
Storage and expiry: always check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; expired electrodes or those with damaged packaging must not be used because the gel may lose conductivity. As this is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date.
Variants of the same Cahnos family (not interchangeable with each other due to proprietary connector): F7950P (Philips), F7952P (Physio-Control / Bexen Cardio / Cardioline / Mindray), F7958P (CU Medical Systems), F7959P (CMOS Drake), F7961P (Nihon Kohden), F7967P (Schiller), F7981P (GE Responder) and F7986P (Mediana D500). For volume orders or tenders, contact the technical department of Cahnos indicating the exact model and serial number of the defibrillator.