Pair of standard paediatric defibrillation electrodes with external cable – Compatible replacement for Philips CodeMaster 100 (M2475B), XE (M1724A), XL (M1723A/B), XL+ (M1722A/B) and HeartStart/HeartStream family · Ref. F7950PW · Original function M3504A

39,75 €

Pair of standard paediatric defibrillation electrodes with external cable (ref. F7950PW), compatible replacement consumable for Philips CodeMaster 100 (M2475B), XE (M1724A), XL (M1723A/B), XL+ (M1722A/B) defibrillators and monitors and the HeartStart/HeartStream family (MRx, XL, XLT and HeartStart 4000). Indicated for patients under 8 years of age or under 25 kg, with reduced active surface of 40 cm² per electrode, low-impedance conductive adhesive gel, metal foil and 1 mm medical foam backing. Single-use, latex-free and phthalate-free, class IIb and ECG monitoring up to 24 h. Reproduces the function of the original Philips M3504A / 989803106951 electrode; check the connector fit and expiry date before use.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7950PW

Description

1. Commercial Introduction

Keep your Philips CodeMaster and HeartStart family defibrillator or monitor always ready to also treat the smallest patients. This pair of standard paediatric electrodes with external cable (reference Cahnos F7950PW) is the replacement consumable indicated for infant defibrillation with CodeMaster 100, XE, XL, XL+ equipment and the HeartStart/HeartStream family. It is sold per pair (2 units) in an individual heat-sealed package and is ready to be integrated into cardiopulmonary resuscitation protocols of emergency services, paediatric intensive care units (UCIP), ambulances, health centres and heart-safe spaces with Philips equipment.

2. Technical explanation of the equipment and procedure

Multifunction defibrillation electrodes are the interface element between the defibrillator and the patient: through them the equipment analyses the cardiac rhythm, delivers the transthoracic shock and, in many models, allows emergency electrocardiogram monitoring. In paediatric patients (under 8 years of age or weighing less than 25 kg) it is essential to attenuate the delivered energy to avoid myocardial injury; therefore this electrode has a reduced active surface of 40 cm² per pad and must be used with the equipment’s paediatric mode switching or with the reduced energy configuration indicated in the defibrillator manual.

The external cable configuration (preconnectable electrode or lead-out) leaves the connector accessible and allows the equipment to be ready for immediate connection, a decisive advantage in paediatric resuscitation. The recommended placement is anterolateral (anteroapical position), so that both pads do not come into contact with each other on the infant’s chest. The low-impedance conductive adhesive gel ensures stable adhesion and a reliable signal, while the metal foil and 1 mm thick medical foam guarantee a uniform distribution of current. They are single-use and disposable: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the packaging. The electrode allows external defibrillation, synchronized cardioversion and ECG monitoring for up to 24 h.

3. Technical Specifications

Parameter Specification
Reference Cahnos (SKU) F7950PW (Cahnos distribution code; the equivalent original factory reference is indicated in block 4)
Product type Pair of standard paediatric multifunction defibrillator electrodes with external cable
Brand / compatible equipment Philips – CodeMaster 100 (M2475B), CodeMaster XE (M1724A), CodeMaster XL (M1723A/B), CodeMaster XL+ (M1722A/B), HeartStart/HeartStream family
Target population Paediatric (< 8 years / < 25 kg)
Total surface (per electrode) 75 cm² (paediatric series)
Active surface (per electrode) 40 cm² (paediatric series)
Adhesive ring width 1 cm
Supported shocks 50 shocks (energy 50–100 J in paediatric configuration; verify according to the equipment’s indications)
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material Medical foam (FOAM) 1 mm thick
Connection type Safety anti-shock connector / clip with external cable
Functions External defibrillation, synchronised cardioversion and ECG monitoring
ECG monitoring Up to 24 h
Operating temperature Between 0 °C and +50 °C
Use Single-use, disposable, non-sterile; latex-free and phthalate-free
Presentation Price per pair (2 units); 5 pairs per box (paediatric series)
Primary packaging 1 pair in heat-sealed polyethylene and aluminium bag, with laser pre-cut and opening notch
Shelf life Approx. 30 months from the date of production; expiry indicated on the packaging
Storage Dry place, between +5 °C and +35 °C
Regulatory classification Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)
Reference standards ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10

Note: the values for active surface (40 cm²), total area (75 cm²), discharges (50–100 J) and adhesive ring (1 cm) correspond to the series of standard paediatric electrodes with external cable in this product family; confirm them with the technical data sheet of the supplied batch and the equipment manual before use in tendering.

Compatibility with defibrillators:

Equipment Models Cable / required accessories
Philips CodeMaster 100 M2475B External cable M1750A/B or M2472A with adapter 05-10200
Philips CodeMaster XE M1724A External cable M1750A/B or M2472A with adapter 05-10200
Philips CodeMaster XL / XL+ M1723A/B · M1722A/B External cable M1750A/B or M2472A with adapter 05-10200
Philips HeartStart / HeartStream MRx (M3535A/M3536A) · XL (M4735A) · XLT (M3500B) · XL+ (861290) · HeartStart 4000 (M5500B) Cable M3507A (barrel connector) or M3508A (plug connector) depending on model

Note: always check the connector fit and the cable of your equipment before clinical use.

4. Equivalences and Cross-References

The reference F7950PW is the Cahnos distribution code for this compatible electrode; it is not an official Philips reference. Philips Healthcare does not publish an F7950PW code: the equivalence with the manufacturer’s official nomenclature corresponds to the original paediatric electrodes of the family with barrel connector (M3504A and, for the infant range of 10–25 kg, M3501A) and with the alternative ordering code 989803106951 (M3504A), verified in the Philips technical specification sheet (4522 962 96291), in GUDID/FDA (DI 00884838022034) and in authorised distributors of original spare parts. The M3501A code also supports the alternative code 989803106921. Any comparison between brands should be understood as comparable at category level, not interchangeable 1:1.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Philips Infant Pads with barrel connector – original paediatric electrodes for HeartStart MRx/XL/XL+ and CodeMaster family M3504A (also 989803106951) Comparable by category (not interchangeable 1:1) Original factory replacement with barrel connector, conductive surface of 75 cm² and 60 cm cable; requires M3507A/M3508A or M1750A/B/M2472A cables depending on the equipment. Code confirmed in Philips technical documentation, GUDID (DI 00884838022034) and authorised distributors; there is no Philips validation authorising the substitution of the original with the compatible replacement F7950PW.
Philips Adult/Child Pads with barrel connector – original adult/child electrodes (≥ 10 kg) M3501A (also 989803106921) Comparable by category (not interchangeable 1:1) Original adult/child with barrel connector; also covers the paediatric range of 10–25 kg. Code confirmed in the Philips technical specification sheet and authorised distributors.
Cardinal Health (Covidien/Kendall) Medi-Trace™ Cadence Pediatric RTS – radiolucent paediatric electrodes with barrel connector compatible with Philips 22661P Comparable by category (not interchangeable 1:1) Paediatric radiotransparent pair for the CodeMaster XL+ family (M1722A/B, M1723A/B), HeartStream XLT, HeartStart XL, MRx and HeartStart 4000; conductive hydrogel with Ag/AgCl technology and 5 pairs per box. Code confirmed in GUDID (DI 20884527022356) and the official Cardinal Health catalogue; check connector, cable and surfaces before replacement.
Nissha Medical Technologies (HeartSync) 97-DEFIB F/G PEDIATRIC-PHILIPS – paediatric patch for the HeartStart XL/T, XL+, MRx and Intrepid family 6600066H (D321) Comparable by category (not interchangeable 1:1) Paediatric radiolucent pair with tin and tin-copper conductive element; total surface of 78.4 cm²; pack of one pair with external cable in heat-sealed bag. Code confirmed in the manufacturer’s official catalogue; not suitable for use with AED: check compatibility with the exact model of the equipment.
ZOLL Medical Pedi-Padz II – original paediatric electrodes 8900-0810 / 8900-0810-01 Comparable by category (not interchangeable 1:1) Original for AED Plus and AED Pro (preconnected, without external cable); hydrogel with tin conductive element and paediatric energy levels of 50/70/85 J. Code confirmed on the manufacturer’s website and GUDID (UDI 00847946001438). Not suitable for Philips equipment due to proprietary connector.
Stryker / Physio-Control Infant/Child Reduced Energy Defibrillation Electrodes (LIFEPAK, pink connector) 11101-000016 Comparable by category (not interchangeable 1:1) Paediatric electrode with energy reduction (200 J → ≈50 J) for the LIFEPAK 500, 1000, EXPRESS and CR Plus AEDs; proprietary QUIK-COMBO connector and algorithm, not suitable for Philips equipment. Code confirmed in the official Stryker store and GUDID (UDI 00721902629013).

There is no equivalence table validated by the manufacturer authorising the substitution of original Philips electrodes with third-party pads: the connector, analysis algorithm and energy management are proprietary. Any substitution must be validated against the defibrillator’s technical data sheet and IFU; consult the Cahnos technical department before use in tenders. Within the Cahnos catalogue there are other references in the same family (standard paediatric with external cable) intended for equipment from other manufacturers, not interchangeable with each other as the connector and algorithm differ: F7961PW (Nihon Kohden), F7964PW (Weinmann MEDUCORE), F7967PW (Schiller), F7969PW (Mediana HeartOn), F7984PW (Instramed), F7986PW (Mediana D500) and F7987PW (ZOLL).

5. Selection tips and variants of interest

Confirm the equipment model: verify that your defibrillator is a Philips CodeMaster 100 (M2475B), XE (M1724A), XL (M1723A/B), XL+ (M1722A/B) or a compatible HeartStart/HeartStream and that the external cable connector fits correctly into the equipment socket before clinical use. On CodeMaster series also check the hands-free cable (M1750A/B or M2472A with adapter 05-10200) and on HeartStream/MRx the M3507A (barrel) or M3508A (plug) cable.

Do not confuse the paediatric and adult versions: this pair is for patients under 8 years of age or under 25 kg; the adult version of the same Philips connector family is supplied under reference F7950W, and the paediatric variant with internal cable under F7950P. Ensure that the equipment switches to paediatric mode or energy (reduced energy setting 50–100 J) according to the defibrillator manual; on manually adjustable models, always select it before the shock.

Check the expiry date: always check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; expired electrodes or those with damaged packaging must not be used (the gel may lose conductivity). For the paediatric supply of the Philips HeartStart FR2/FR2+ AEDs, you have the limited-energy references F7950WPL (external cable type W) and F7950PL, which reproduce the 150 J → 50 J attenuation of the original M3870A. If X-rays or CT scans are anticipated during care, consider the paediatric radiotransparent series F7750P from the same connector family. Plan your replacement: as it is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date. For volume orders or tenders, contact the Cahnos technical department stating the exact model and serial number of your equipment.

Additional information

Manufacturer reference

Philips M3504A / 989803106951 (Infant Pads with barrel connector); M3501A (Adult/Child)

Compatibility

Philips – CodeMaster 100 (M2475B), XE (M1724A), XL (M1723A/B), XL+ (M1722A/B), HeartStart/HeartStream family (MRx, XL, XLT, HeartStart 4000)

Required cables

M1750A/B or M2472A with adapter 05-10200 (CodeMaster); M3507A barrel or M3508A plug (HeartStream/MRx)

Target population

Paediatric (< 8 years / < 25 kg)

Total surface per electrode

75 cm²

Active surface per electrode

40 cm²

Adhesive ring width

1 cm

Supported shocks

50 discharges (paediatric energy 50–100 J)

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

Backing material

1 mm medical foam (FOAM)

Connection type

Safety anti-shock connector / clip with external cable

ECG monitoring

Up to 24 h

Use

Single-use, disposable, non-sterile

Latex-free and phthalate-free

Yes

Presentation

Price per pair (2 units); 5 pairs per box (paediatric series)

Shelf life

Approx. 30 months from the date of production; expiry indicated on the packaging

Storage

Dry place, between +5 °C and +35 °C

Regulatory classification

Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10

Original manufacturer code

Philips M3504A / 989803106951 (original paediatric electrodes with barrel connector)

Product type

Pair of standard paediatric multifunction defibrillator electrodes with external cable

Patient type

Paediatric (

External cable

Yes (preconnectable / lead-out)

Functions

External defibrillation, synchronised cardioversion and ECG monitoring

Operating temperature

0 °C to +50 °C

Cables and accessories

M1750A/B or M2472A with adapter 05-10200 (CodeMaster); M3507A (barrel) or M3508A (plug) depending on HeartStart/HeartStream model