Description
1. Commercial Introduction
Keep your Philips CodeMaster and HeartStart family defibrillator or monitor always ready to also treat the smallest patients. This pair of standard paediatric electrodes with external cable (reference Cahnos F7950PW) is the replacement consumable indicated for infant defibrillation with CodeMaster 100, XE, XL, XL+ equipment and the HeartStart/HeartStream family. It is sold per pair (2 units) in an individual heat-sealed package and is ready to be integrated into cardiopulmonary resuscitation protocols of emergency services, paediatric intensive care units (UCIP), ambulances, health centres and heart-safe spaces with Philips equipment.
2. Technical explanation of the equipment and procedure
Multifunction defibrillation electrodes are the interface element between the defibrillator and the patient: through them the equipment analyses the cardiac rhythm, delivers the transthoracic shock and, in many models, allows emergency electrocardiogram monitoring. In paediatric patients (under 8 years of age or weighing less than 25 kg) it is essential to attenuate the delivered energy to avoid myocardial injury; therefore this electrode has a reduced active surface of 40 cm² per pad and must be used with the equipment’s paediatric mode switching or with the reduced energy configuration indicated in the defibrillator manual.
The external cable configuration (preconnectable electrode or lead-out) leaves the connector accessible and allows the equipment to be ready for immediate connection, a decisive advantage in paediatric resuscitation. The recommended placement is anterolateral (anteroapical position), so that both pads do not come into contact with each other on the infant’s chest. The low-impedance conductive adhesive gel ensures stable adhesion and a reliable signal, while the metal foil and 1 mm thick medical foam guarantee a uniform distribution of current. They are single-use and disposable: do not reuse under any circumstances and replace after each intervention or upon reaching the expiry date printed on the packaging. The electrode allows external defibrillation, synchronized cardioversion and ECG monitoring for up to 24 h.
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Reference Cahnos (SKU) | F7950PW (Cahnos distribution code; the equivalent original factory reference is indicated in block 4) |
| Product type | Pair of standard paediatric multifunction defibrillator electrodes with external cable |
| Brand / compatible equipment | Philips – CodeMaster 100 (M2475B), CodeMaster XE (M1724A), CodeMaster XL (M1723A/B), CodeMaster XL+ (M1722A/B), HeartStart/HeartStream family |
| Target population | Paediatric (< 8 years / < 25 kg) |
| Total surface (per electrode) | 75 cm² (paediatric series) |
| Active surface (per electrode) | 40 cm² (paediatric series) |
| Adhesive ring width | 1 cm |
| Supported shocks | 50 shocks (energy 50–100 J in paediatric configuration; verify according to the equipment’s indications) |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (FOAM) 1 mm thick |
| Connection type | Safety anti-shock connector / clip with external cable |
| Functions | External defibrillation, synchronised cardioversion and ECG monitoring |
| ECG monitoring | Up to 24 h |
| Operating temperature | Between 0 °C and +50 °C |
| Use | Single-use, disposable, non-sterile; latex-free and phthalate-free |
| Presentation | Price per pair (2 units); 5 pairs per box (paediatric series) |
| Primary packaging | 1 pair in heat-sealed polyethylene and aluminium bag, with laser pre-cut and opening notch |
| Shelf life | Approx. 30 months from the date of production; expiry indicated on the packaging |
| Storage | Dry place, between +5 °C and +35 °C |
| Regulatory classification | Medical device class IIb (Directive 93/42/EEC; EU Regulation 2017/745) |
| Reference standards | ANSI/AAMI DF-80; IEC/EN 60601-1, IEC/EN 60601-2-4; ISO 10993-10 |
Note: the values for active surface (40 cm²), total area (75 cm²), discharges (50–100 J) and adhesive ring (1 cm) correspond to the series of standard paediatric electrodes with external cable in this product family; confirm them with the technical data sheet of the supplied batch and the equipment manual before use in tendering.
Compatibility with defibrillators:
| Equipment | Models | Cable / required accessories |
|---|---|---|
| Philips CodeMaster 100 | M2475B | External cable M1750A/B or M2472A with adapter 05-10200 |
| Philips CodeMaster XE | M1724A | External cable M1750A/B or M2472A with adapter 05-10200 |
| Philips CodeMaster XL / XL+ | M1723A/B · M1722A/B | External cable M1750A/B or M2472A with adapter 05-10200 |
| Philips HeartStart / HeartStream | MRx (M3535A/M3536A) · XL (M4735A) · XLT (M3500B) · XL+ (861290) · HeartStart 4000 (M5500B) | Cable M3507A (barrel connector) or M3508A (plug connector) depending on model |
Note: always check the connector fit and the cable of your equipment before clinical use.
4. Equivalences and Cross-References
The reference F7950PW is the Cahnos distribution code for this compatible electrode; it is not an official Philips reference. Philips Healthcare does not publish an F7950PW code: the equivalence with the manufacturer’s official nomenclature corresponds to the original paediatric electrodes of the family with barrel connector (M3504A and, for the infant range of 10–25 kg, M3501A) and with the alternative ordering code 989803106951 (M3504A), verified in the Philips technical specification sheet (4522 962 96291), in GUDID/FDA (DI 00884838022034) and in authorised distributors of original spare parts. The M3501A code also supports the alternative code 989803106921. Any comparison between brands should be understood as comparable at category level, not interchangeable 1:1.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
|---|---|---|---|---|
| Philips | Infant Pads with barrel connector – original paediatric electrodes for HeartStart MRx/XL/XL+ and CodeMaster family | M3504A (also 989803106951) | Comparable by category (not interchangeable 1:1) | Original factory replacement with barrel connector, conductive surface of 75 cm² and 60 cm cable; requires M3507A/M3508A or M1750A/B/M2472A cables depending on the equipment. Code confirmed in Philips technical documentation, GUDID (DI 00884838022034) and authorised distributors; there is no Philips validation authorising the substitution of the original with the compatible replacement F7950PW. |
| Philips | Adult/Child Pads with barrel connector – original adult/child electrodes (≥ 10 kg) | M3501A (also 989803106921) | Comparable by category (not interchangeable 1:1) | Original adult/child with barrel connector; also covers the paediatric range of 10–25 kg. Code confirmed in the Philips technical specification sheet and authorised distributors. |
| Cardinal Health (Covidien/Kendall) | Medi-Trace™ Cadence Pediatric RTS – radiolucent paediatric electrodes with barrel connector compatible with Philips | 22661P | Comparable by category (not interchangeable 1:1) | Paediatric radiotransparent pair for the CodeMaster XL+ family (M1722A/B, M1723A/B), HeartStream XLT, HeartStart XL, MRx and HeartStart 4000; conductive hydrogel with Ag/AgCl technology and 5 pairs per box. Code confirmed in GUDID (DI 20884527022356) and the official Cardinal Health catalogue; check connector, cable and surfaces before replacement. |
| Nissha Medical Technologies (HeartSync) | 97-DEFIB F/G PEDIATRIC-PHILIPS – paediatric patch for the HeartStart XL/T, XL+, MRx and Intrepid family | 6600066H (D321) | Comparable by category (not interchangeable 1:1) | Paediatric radiolucent pair with tin and tin-copper conductive element; total surface of 78.4 cm²; pack of one pair with external cable in heat-sealed bag. Code confirmed in the manufacturer’s official catalogue; not suitable for use with AED: check compatibility with the exact model of the equipment. |
| ZOLL Medical | Pedi-Padz II – original paediatric electrodes | 8900-0810 / 8900-0810-01 | Comparable by category (not interchangeable 1:1) | Original for AED Plus and AED Pro (preconnected, without external cable); hydrogel with tin conductive element and paediatric energy levels of 50/70/85 J. Code confirmed on the manufacturer’s website and GUDID (UDI 00847946001438). Not suitable for Philips equipment due to proprietary connector. |
| Stryker / Physio-Control | Infant/Child Reduced Energy Defibrillation Electrodes (LIFEPAK, pink connector) | 11101-000016 | Comparable by category (not interchangeable 1:1) | Paediatric electrode with energy reduction (200 J → ≈50 J) for the LIFEPAK 500, 1000, EXPRESS and CR Plus AEDs; proprietary QUIK-COMBO connector and algorithm, not suitable for Philips equipment. Code confirmed in the official Stryker store and GUDID (UDI 00721902629013). |
There is no equivalence table validated by the manufacturer authorising the substitution of original Philips electrodes with third-party pads: the connector, analysis algorithm and energy management are proprietary. Any substitution must be validated against the defibrillator’s technical data sheet and IFU; consult the Cahnos technical department before use in tenders. Within the Cahnos catalogue there are other references in the same family (standard paediatric with external cable) intended for equipment from other manufacturers, not interchangeable with each other as the connector and algorithm differ: F7961PW (Nihon Kohden), F7964PW (Weinmann MEDUCORE), F7967PW (Schiller), F7969PW (Mediana HeartOn), F7984PW (Instramed), F7986PW (Mediana D500) and F7987PW (ZOLL).
5. Selection tips and variants of interest
Confirm the equipment model: verify that your defibrillator is a Philips CodeMaster 100 (M2475B), XE (M1724A), XL (M1723A/B), XL+ (M1722A/B) or a compatible HeartStart/HeartStream and that the external cable connector fits correctly into the equipment socket before clinical use. On CodeMaster series also check the hands-free cable (M1750A/B or M2472A with adapter 05-10200) and on HeartStream/MRx the M3507A (barrel) or M3508A (plug) cable.
Do not confuse the paediatric and adult versions: this pair is for patients under 8 years of age or under 25 kg; the adult version of the same Philips connector family is supplied under reference F7950W, and the paediatric variant with internal cable under F7950P. Ensure that the equipment switches to paediatric mode or energy (reduced energy setting 50–100 J) according to the defibrillator manual; on manually adjustable models, always select it before the shock.
Check the expiry date: always check the date printed on the packaging and store in a dry place between +5 °C and +35 °C; expired electrodes or those with damaged packaging must not be used (the gel may lose conductivity). For the paediatric supply of the Philips HeartStart FR2/FR2+ AEDs, you have the limited-energy references F7950WPL (external cable type W) and F7950PL, which reproduce the 150 J → 50 J attenuation of the original M3870A. If X-rays or CT scans are anticipated during care, consider the paediatric radiotransparent series F7750P from the same connector family. Plan your replacement: as it is a single-use consumable, maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date. For volume orders or tenders, contact the Cahnos technical department stating the exact model and serial number of your equipment.