We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Pair of paediatric defibrillation electrodes with external cable · Compatible with ZOLL AED Plus, AED Pro and AED 3

38,00 €

Pair of paediatric defibrillation electrodes with external cable for ZOLL AED Plus, AED Pro and AED 3 defibrillators. Indicated for paediatric patients up to 8 years of age or under 25 kg, with an active surface area of 40 cm² per electrode and low-impedance conductive gel. The device detects its connection and automatically adjusts the rhythm analysis and energy to paediatric mode. Single-use product in individual sterile packaging, with an approximate shelf life of 24 months. Essential replacement consumable for emergency services, ambulances, schools and centres with ZOLL equipment. Reference Cahnos: F7987PW.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7987PW

Description

1. General description

Keep your ZOLL defibrillator always ready to respond to a paediatric emergency with this pair of defibrillation electrodes with external cable, a single-use consumable designed for emergency services, ambulances, hospitals, schools and any location equipped with a ZOLL AED. Designed for paediatric patients up to 8 years old or under 25 kg, they ensure the safe and effective delivery of the shock with the attenuated energy required by a child’s body.

The price corresponds to a pair of electrodes (2 units) in an individual sterile package, ready to be integrated into your centre’s defibrillation protocols. Cahnos reference: F7987PW.

2. Technical explanation

Multifunction defibrillation electrodes are the interface element between the defibrillator and the patient: they transmit the energy of the transthoracic shock and, in many models, also allow emergency ECG monitoring. In paediatric patients it is essential to attenuate the delivered energy to avoid myocardial injury; therefore this electrode has a reduced active surface area (40 cm² per electrode) and must be used with the device’s paediatric mode switching.

On the ZOLL AED Plus and AED Pro, the connection of these paediatric electrodes is detected automatically: the device switches to a specific paediatric rhythm analysis algorithm and adjusts the energy to paediatric levels. On the ZOLL AED 3, paediatric care requires activating the device’s child mode (Child Mode); always check the connector compatibility with your exact model.

The recommended placement is anterolateral, so that both pads do not come into contact with each other on the child’s chest. They are single-use: do not reuse under any circumstances and replace after expiry or after continuous monitoring.

3. Technical Specifications

Characteristic Detail
Compatibility ZOLL AED Plus, AED Pro and AED 3 (verify connector and paediatric mode of the device)
Electrode type Standard paediatric with external cable
Target population Paediatric patients (up to 8 years / under 25 kg)
Total surface (per electrode) 75 cm²
Active surface (per electrode) 40 cm²
Cable length 120 cm
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material Medical foam (FOAM) 1 mm thick
Supported shocks Up to 50 shocks (paediatric energy)
Type of use Single-use, disposable
Sterility / presentation Individual sterile package; price per pair (2 units)
Paediatric mode detection Automatic on AED Plus and AED Pro; child mode on AED 3
Shelf life Approximately 24 months from manufacture
Latex / phthalates Latex-free
Regulatory classification Medical device class IIb (Directive 93/42/EEC)
Reference standards ANSI/AAMI DF-80; IEC/EN 60601-1; IEC/EN 60601-2-4; ISO 10993

Specifications corresponding to the family of standard electrodes with external cable; consult the labelling of the supplied batch before clinical use.

4. Equivalences and Cross-References

This electrode belongs to the family of standard paediatric consumables with external cable compatible with ZOLL AEDs. The original spare parts from the device manufacturer (ZOLL Medical Corporation), verified on the official ZOLL website and in the GUDID regulatory database, are listed below:

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
ZOLL Medical Corporation Pedi·padz® II (original paediatric electrodes) 8900-0810 / 8900-0810-01 Comparable by category (not interchangeable 1:1) Original preconnected spare part (Preconnect™) for AED Plus and AED Pro: no external cable. Automatic paediatric mode detection with 50/70/85 J energy. Verified on the manufacturer’s website and GUDID (00847946001438).
ZOLL Medical Corporation CPR Uni-padz® / CPR Uni-padz® III (for AED 3) 8900-000260 / 8900-000280-01 Comparable by category (not interchangeable 1:1) Universal adult/paediatric electrodes exclusive to the ZOLL AED 3: in a paediatric patient they are repositioned and child mode is selected manually. They are not a dedicated paediatric electrode and do not have an external cable. Verified on the manufacturer’s website.

Within the Cahnos catalogue there are other references in the same family (standard paediatric with external cable) intended for equipment from other manufacturers, so they are not interchangeable with each other: F7964PW (Weinmann MEDUCORE), F7961PW (Nihon Kohden), F7967PW (Schiller), F7969PW (Mediana HeartOn), F7984PW (Instramed) and F7986PW (Mediana D500). The adult version for the same ZOLL device is F7987W.

There is no equivalence table validated by the manufacturer; consult the technical department before use in tenders.

5. Selection tips and variants of interest

  • Confirm the exact model of the device: verify that your defibrillator is a ZOLL AED Plus, AED Pro or AED 3 and that the external cable connector fits correctly into the device socket before clinical use.
  • Paediatric mode: on AED Plus and AED Pro detection is automatic; on AED 3 remember to activate child mode (Child Mode) according to the manual.
  • Do not confuse the paediatric and adult versions: the paediatric version is indicated for children under 8 years old or under 25 kg; for adult patients use reference F7987W.
  • Storage and expiry: always check the expiry date (approx. 24 months from manufacture) and the condition of the packaging; expired electrodes or those with damaged packaging must not be used.
  • Plan your replacement: as this is a single-use consumable, it is recommended to maintain a minimum stock per defibrillation unit and rotate stock according to the expiry date.

Additional information

Compatibility

ZOLL AED Plus / AED Pro / AED 3 (verify connector)

Patient type

Paediatric (up to 8 years / < 25 kg)

Electrode type

Standard with external cable

Cable length

120 cm

Total surface per electrode

75 cm²

Active surface per electrode

40 cm²

Backing material

1 mm medical foam (FOAM)

Conductive material

Metal foil

Conductive gel

Low-impedance conductive adhesive gel

Supported shocks

Up to 50 shocks (paediatric energy)

ECG monitoring

Up to 24 h

Use

Single-use, disposable

Regulatory classification

Medical device class IIb (Directive 93/42/EEC)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1; IEC/EN 60601-2-4; ISO 10993

Storage

Dry place, between +5 °C and +35 °C

Presentation

Price per pair of electrodes (2 units)

Paediatric mode detection

Automatic on AED Plus / AED Pro; child mode on AED 3

Sterility

Individual sterile packaging

Shelf life

Approx. 24 months from manufacture

Latex

Latex-free