Description
1. Introduction
Paediatric defibrillator electrodes are a critical component for patient safety in healthcare and emergency settings. This model (ref. F7957PL) has been designed to offer optimal compatibility and performance with the automated defibrillators Cardiac Science Powerheart AED and GE Responder AED, the two major families that have historically shared the same infant pad connection scheme. It is the indicated solution for schools, nurseries, sports centres, paediatric practices, emergency services and any public access defibrillation point with a child population. Thanks to its integrated energy attenuator, any rescuer has a safe paediatric shock without needing to configure the device.
2. Technical explanation of the equipment and procedure
The automated external defibrillator (AED) analyses the cardiac rhythm through the multifunction electrodes and, if it detects a shockable rhythm (ventricular fibrillation or ventricular tachycardia), delivers a biphasic shock. In paediatric patients —under 8 years of age or weighing less than 25 kg— applying adult energy can be harmful to the infant myocardium. Therefore, this electrode incorporates a limited energy attenuator: the 200 J delivered by the defibrillator are reduced to 50 J at the patient, a level suitable for paediatric resuscitation in accordance with international CPR guidelines.
The pads are placed following the anatomical diagrams on the packaging (anterior-posterior position in small children) and allow, in addition to defibrillation, monitoring of the cardiac rhythm during care. They are single-use: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging.
3. Technical Specifications
| Compatible brand | Cardiac Science and General Electric (GE) |
| Compatible models | Powerheart AED-9200 series, Powerheart AED G3-9300 series (G3, G3 Plus, G3 Pro), FirstSave AED G3 9300 series; GE Responder AED and Responder AED Pro |
| Application type | Paediatric, designed for use in infant and child patients |
| Main function | Safe and effective defibrillation in cardiac emergency situations |
| Field | Specification |
| Reference | F7957PL |
| Electrode type | Limited-energy paediatric multifunction, 1 pair (2 pieces), disposable |
| Indicated population | Under 8 years of age or weighing less than 25 kg |
| Energy reduction | 200 J at the defibrillator → 50 J at the patient |
| Cable length | 120 cm |
| Total surface (per electrode) | 75 cm² (paediatric series) |
| Active surface (per electrode) | 40 cm² (paediatric series) |
| Supported shocks | 50–100 J (paediatric series) |
| Conductive gel | Low-impedance conductive adhesive gel |
| Conductive material | Metal foil |
| Backing material | Medical foam (1 mm thick) |
| Connection type | Specific anti-shock safety connector |
| ECG monitoring | Max. 24 h |
| Operating temperature | 0 °C to +50 °C |
| Storage temperature | +5 °C to +35 °C (extremes −30 °C to +65 °C max. 7 days) |
| Use | Single-use, disposable; latex- and phthalate-free |
| Presentation | 1 pair in heat-sealed polyethylene and aluminium bag, with easy-open notch |
| Regulatory standard | Medical device class IIb (Directive 93/42/EEC); ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993 |
| Shelf life | 30 months from the date of production (see labelling) |
| Expiry | As indicated on the packaging; do not use after the expiry date |
4. Equivalences and Cross-References
The Cahnos F7957PL replacement is a paediatric multifunction electrode with limited energy (integrated attenuator from 200 J to 50 J) designed for the AEDs of the Cardiac Science Powerheart (9200/9300 series), FirstSave G3 and GE Responder AED / AED Pro families. The original factory reference for these same devices is the Powerheart Pediatric Pads 9730-002, verified in the GUDID regulatory database (FDA) as a single-use paediatric external defibrillation electrode (UDI-DI 00812394020256 / 00812394020935). For the GE Responder AED Pro, the operator’s manual prescribes the reference 2019199-003 (Pediatric Attenuated Defibrillation Electrode Pads), also verified in GUDID (UDI-DI 00812394020607). There is no equivalence table validated by the device manufacturer that authorises the exchange of pads between brands: the connector, energy attenuation and analysis algorithm are proprietary. Any comparison with other brands should be understood as comparable at category level, not interchangeable 1:1, verifying connector, energy range and algorithm before any substitution.
| Manufacturer / Brand | Family / Model | Reference code / SKU | Equivalence level | Technical differences / Remarks |
| Cardiac Science (ZOLL) | Powerheart Pediatric Pads (energy reduction ~50 J) | 9730-002 | Comparable by category (not interchangeable 1:1) | Original OEM reference for the same Powerheart 9200/9300 models (G3, G3 Plus, G3 Pro), FirstSave G3 and GE Responder AED; integrated attenuator at ~50 J and original proprietary connector. Verified in GUDID (UDI-DI 00812394020256 / 00812394020935). |
| Cardiac Science / GE Healthcare | Powerheart Pediatric Pads under GE reference (for Responder AED Pro) | 2019199-003 | Comparable by category (not interchangeable 1:1) | OEM variant under GE part number, prescribed in the GE Responder AED Pro operator’s manual for patients under 8 years of age or less than 25 kg. Verified in GUDID (UDI-DI 00812394020607). |
| ZOLL Medical | Pedi-Padz II (paediatric electrode) | 8900-0810-01 | Comparable by category (not interchangeable 1:1) | Same paediatric range (0–8 years / <25 kg) with paediatric energy 50/70/85 J managed by the device; proprietary connector, algorithm and electronics; exclusive to ZOLL AED Plus and AED Pro. Code confirmed in the official ZOLL store. |
| Philips | HeartStart OnSite / Home infant & child SMART Pads | M5072A | Comparable by category (not interchangeable 1:1) | Pad cartridge with integrated attenuator that reduces the shock to ≈50 J for <8 years or <25 kg; proprietary connector Philips; only for HeartStart OnSite / Home / HS1. |
| Defibtech | Lifeline AED Child / Pediatric Electrode Pads | DDP-200P | Comparable by category (not interchangeable 1:1) | Paediatric electrodes with integrated energy attenuator for <8 years or <25 kg; connector, algorithm and management electronics proprietary to the Lifeline / Lifeline AUTO equipment. |
There is no equivalence table validated by the equipment manufacturer; consult the Cahnos technical department before use in tenders.
5. Selection tips and variants of interest
- Confirm the device model: this electrode corresponds to the Cardiac Science Powerheart series 9200, G3 series 9300 (G3, G3 Plus, G3 Pro), FirstSave G3 9300 and GE Responder AED / AED Pro. It is not valid for other devices with a different connector.
- Check the reference and expiry date: before ordering, verify the code F7957PL and the expiry date on the packaging; do not force the installation of an expired electrode (the gel may lose conductivity).
- Paediatric provision: in centres with a child population, always keep a pair of paediatric electrodes with the AED and periodically check that the device is operational with the pads in date.
- Variants within the Cahnos catalogue: F7957WPL (same paediatric family with external lead-out cable) and, for other devices, F7950PL (Philips Heartstream FR2/FR2+), F7952PL (Physio-Control LIFEPAK 500/1000 with pink connector), F7958PL (CU Medical Paramedic CU-ER1) and F7959PL (CU Medical i-PAD NF1200), all with limited energy.
- Maintenance: manage stock rotation by expiry date (shelf life of up to 30 months) and always replace the electrode after use or expiry. For volume orders or tenders, contact the Cahnos technical department stating the exact model and serial number of the device.