Paediatric AED defibrillator electrode with limited energy F7957PL (200 J → 50 J) – Replacement compatible with Cardiac Science Powerheart AED (series 9200/9300), FirstSave G3 and GE Responder AED / AED Pro

62,50 €

Paediatric defibrillator electrode with limited energy (ref. F7957PL) compatible with the Cardiac Science Powerheart series 9200, Powerheart G3 series 9300 (G3, G3 Plus, G3 Pro), FirstSave G3 and GE Responder AED / AED Pro AEDs. Indicated for patients under 8 years of age or weighing less than 25 kg: its integrated attenuator converts the defibrillator’s 200 J into 50 J at the patient, ensuring a safe and effective shock in accordance with paediatric CPR guidelines. Pair of disposable multifunction pads with low-impedance conductive adhesive gel, 120 cm cable and specific anti-shock connector, in heat-sealed packaging. Medical device class IIb.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7957PL

Description

1. Introduction

Paediatric defibrillator electrodes are a critical component for patient safety in healthcare and emergency settings. This model (ref. F7957PL) has been designed to offer optimal compatibility and performance with the automated defibrillators Cardiac Science Powerheart AED and GE Responder AED, the two major families that have historically shared the same infant pad connection scheme. It is the indicated solution for schools, nurseries, sports centres, paediatric practices, emergency services and any public access defibrillation point with a child population. Thanks to its integrated energy attenuator, any rescuer has a safe paediatric shock without needing to configure the device.

2. Technical explanation of the equipment and procedure

The automated external defibrillator (AED) analyses the cardiac rhythm through the multifunction electrodes and, if it detects a shockable rhythm (ventricular fibrillation or ventricular tachycardia), delivers a biphasic shock. In paediatric patients —under 8 years of age or weighing less than 25 kg— applying adult energy can be harmful to the infant myocardium. Therefore, this electrode incorporates a limited energy attenuator: the 200 J delivered by the defibrillator are reduced to 50 J at the patient, a level suitable for paediatric resuscitation in accordance with international CPR guidelines.

The pads are placed following the anatomical diagrams on the packaging (anterior-posterior position in small children) and allow, in addition to defibrillation, monitoring of the cardiac rhythm during care. They are single-use: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging.

3. Technical Specifications

Compatible brand Cardiac Science and General Electric (GE)
Compatible models Powerheart AED-9200 series, Powerheart AED G3-9300 series (G3, G3 Plus, G3 Pro), FirstSave AED G3 9300 series; GE Responder AED and Responder AED Pro
Application type Paediatric, designed for use in infant and child patients
Main function Safe and effective defibrillation in cardiac emergency situations
Field Specification
Reference F7957PL
Electrode type Limited-energy paediatric multifunction, 1 pair (2 pieces), disposable
Indicated population Under 8 years of age or weighing less than 25 kg
Energy reduction 200 J at the defibrillator → 50 J at the patient
Cable length 120 cm
Total surface (per electrode) 75 cm² (paediatric series)
Active surface (per electrode) 40 cm² (paediatric series)
Supported shocks 50–100 J (paediatric series)
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material Medical foam (1 mm thick)
Connection type Specific anti-shock safety connector
ECG monitoring Max. 24 h
Operating temperature 0 °C to +50 °C
Storage temperature +5 °C to +35 °C (extremes −30 °C to +65 °C max. 7 days)
Use Single-use, disposable; latex- and phthalate-free
Presentation 1 pair in heat-sealed polyethylene and aluminium bag, with easy-open notch
Regulatory standard Medical device class IIb (Directive 93/42/EEC); ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993
Shelf life 30 months from the date of production (see labelling)
Expiry As indicated on the packaging; do not use after the expiry date

4. Equivalences and Cross-References

The Cahnos F7957PL replacement is a paediatric multifunction electrode with limited energy (integrated attenuator from 200 J to 50 J) designed for the AEDs of the Cardiac Science Powerheart (9200/9300 series), FirstSave G3 and GE Responder AED / AED Pro families. The original factory reference for these same devices is the Powerheart Pediatric Pads 9730-002, verified in the GUDID regulatory database (FDA) as a single-use paediatric external defibrillation electrode (UDI-DI 00812394020256 / 00812394020935). For the GE Responder AED Pro, the operator’s manual prescribes the reference 2019199-003 (Pediatric Attenuated Defibrillation Electrode Pads), also verified in GUDID (UDI-DI 00812394020607). There is no equivalence table validated by the device manufacturer that authorises the exchange of pads between brands: the connector, energy attenuation and analysis algorithm are proprietary. Any comparison with other brands should be understood as comparable at category level, not interchangeable 1:1, verifying connector, energy range and algorithm before any substitution.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Cardiac Science (ZOLL) Powerheart Pediatric Pads (energy reduction ~50 J) 9730-002 Comparable by category (not interchangeable 1:1) Original OEM reference for the same Powerheart 9200/9300 models (G3, G3 Plus, G3 Pro), FirstSave G3 and GE Responder AED; integrated attenuator at ~50 J and original proprietary connector. Verified in GUDID (UDI-DI 00812394020256 / 00812394020935).
Cardiac Science / GE Healthcare Powerheart Pediatric Pads under GE reference (for Responder AED Pro) 2019199-003 Comparable by category (not interchangeable 1:1) OEM variant under GE part number, prescribed in the GE Responder AED Pro operator’s manual for patients under 8 years of age or less than 25 kg. Verified in GUDID (UDI-DI 00812394020607).
ZOLL Medical Pedi-Padz II (paediatric electrode) 8900-0810-01 Comparable by category (not interchangeable 1:1) Same paediatric range (0–8 years / <25 kg) with paediatric energy 50/70/85 J managed by the device; proprietary connector, algorithm and electronics; exclusive to ZOLL AED Plus and AED Pro. Code confirmed in the official ZOLL store.
Philips HeartStart OnSite / Home infant & child SMART Pads M5072A Comparable by category (not interchangeable 1:1) Pad cartridge with integrated attenuator that reduces the shock to ≈50 J for <8 years or <25 kg; proprietary connector Philips; only for HeartStart OnSite / Home / HS1.
Defibtech Lifeline AED Child / Pediatric Electrode Pads DDP-200P Comparable by category (not interchangeable 1:1) Paediatric electrodes with integrated energy attenuator for <8 years or <25 kg; connector, algorithm and management electronics proprietary to the Lifeline / Lifeline AUTO equipment.

There is no equivalence table validated by the equipment manufacturer; consult the Cahnos technical department before use in tenders.

5. Selection tips and variants of interest

  • Confirm the device model: this electrode corresponds to the Cardiac Science Powerheart series 9200, G3 series 9300 (G3, G3 Plus, G3 Pro), FirstSave G3 9300 and GE Responder AED / AED Pro. It is not valid for other devices with a different connector.
  • Check the reference and expiry date: before ordering, verify the code F7957PL and the expiry date on the packaging; do not force the installation of an expired electrode (the gel may lose conductivity).
  • Paediatric provision: in centres with a child population, always keep a pair of paediatric electrodes with the AED and periodically check that the device is operational with the pads in date.
  • Variants within the Cahnos catalogue: F7957WPL (same paediatric family with external lead-out cable) and, for other devices, F7950PL (Philips Heartstream FR2/FR2+), F7952PL (Physio-Control LIFEPAK 500/1000 with pink connector), F7958PL (CU Medical Paramedic CU-ER1) and F7959PL (CU Medical i-PAD NF1200), all with limited energy.
  • Maintenance: manage stock rotation by expiry date (shelf life of up to 30 months) and always replace the electrode after use or expiry. For volume orders or tenders, contact the Cahnos technical department stating the exact model and serial number of the device.

Additional information

Reference

F7957PL

Brand family

FIAB EuroDefiPads

Product type

Paediatric multifunction electrode with limited energy, 1 disposable pair

Indicated population

Children under 8 years or weighing less than 25 kg

Total surface

75 cm² per electrode (paediatric series)

Active surface

40 cm² per electrode (paediatric series)

Supported shocks

50–100 J (paediatric series)

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

Connection

Specific anti-shock safety connector

ECG monitoring

Max. 24 h

Presentation

1 pair in heat-sealed polyethylene and aluminium bag, with easy-open notch

Use

Single-use, disposable; latex- and phthalate-free

Classification

Medical device class IIb (Directive 93/42/EEC)

Regulatory standard

Medical device class IIb (Directive 93/42/EEC); ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993

Shelf life

30 months from the date of production

Expiry

As indicated on the packaging; do not use after the expiry date

Family

EuroDefiPads (FIAB SpA)

Electrode type

Limited-energy paediatric multifunction, 1 pair (2 pieces), disposable

Energy reduction

200 J at the defibrillator → 50 J at the patient

Cable length

120 cm

Total surface per electrode

75 cm²

Active surface per electrode

40 cm²

Backing material

Medical foam (1 mm thick)

Connection type

Specific anti-shock safety connector

Compatibility

Cardiac Science Powerheart AED 9200 / G3 9300 (G3, G3 Plus, G3 Pro), FirstSave G3; GE Responder AED / AED Pro

Operating temperature

0 °C to +50 °C

Storage temperature

+5 °C to +35 °C (extremes −30 °C to +65 °C max. 7 days)