We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Limited-energy paediatric AED electrode 200 J → 50 J with external 120 cm lead-out cable – Compatible replacement for Cardiac Science Powerheart G3 (series 9200/9300), FirstSave G3 and GE Responder AED / AED Pro – Ref. F7957WPL

72,50 €

Limited-energy paediatric AED electrode (ref. F7957WPL, 1 disposable pair) with external cable 120 cm lead-out: the AED is pre-connected and operational in seconds, without opening the sealed pouch. Its integrated attenuator converts the defibrillator’s 200 J into 50 J delivered to the patient, the recommended dose for children under 8 years of age or weighing less than 25 kg. Compatible with Cardiac Science Powerheart AED series 9200 and G3 series 9300 (G3, G3 Plus, G3 Pro), FirstSave G3 and GE Responder AED / AED Pro. Multifunction pads with low-impedance conductive adhesive gel, active surface area of 40 cm² per electrode and ECG monitoring for up to 24 h. Medical device class IIb, latex-free and phthalate-free; price per pair.

International shipping. Import duties and taxes are payable by the recipient.

Reference
F7957WPL

Description

1. Commercial Introduction

Ensure the safe care of the smallest patients at any heart-safe location with this pair of paediatric AED electrodes with limited energy, reference F7957WPL, with external lead-out cable to keep the defibrillator pre-connected and operational within seconds. It is the clinical replacement indicated for schools, nurseries, sports centres, paediatric practices, emergency services and public-access defibrillation areas with a high number of children: its integrated attenuator delivers a shock adapted to paediatric physiology without compromising the equipment’s response speed. A reliable, cost-optimised solution compliant with European medical device standards for paediatric resuscitation.

2. Technical explanation of the equipment and procedure

The automated external defibrillator (AED) analyses the cardiac rhythm through the multifunction electrodes and, if it detects a shockable rhythm (ventricular fibrillation or ventricular tachycardia), delivers a biphasic shock. In paediatric patients —under 8 years of age or weighing less than 25 kg— applying adult energy can be harmful to the child’s myocardium. This electrode therefore incorporates an integrated limited-energy attenuator: the 200 J delivered by the defibrillator is reduced to 50 J at the patient, a level suitable for paediatric resuscitation in accordance with international CPR guidelines.

Thanks to the external lead-out cable variant, the connector remains accessible without opening the sealed pouch, so the equipment stays in stand-by with the pair installed and ready within seconds. The pads are placed following the anatomical diagrams on the packaging (anterior-posterior position in small children) and also allow, in addition to defibrillation, cardiac rhythm monitoring during care (max. 24 h). They incorporate low-impedance conductive adhesive gel on a medical foam backing with a conductive metal foil, ensuring a reliable signal and uniform current distribution. They are single-use: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging.

3. Technical Specifications

Paediatric multifunction electrode with limited energy from the EuroDefiPads series, designed for direct connection to Cardiac Science Powerheart and GE Responder AED / AED Pro defibrillators, in its external lead-out cable variant.

Field Specification
Reference Cahnos (SKU) F7957WPL
Electrode type Limited-energy paediatric multifunction, 1 pair (2 pieces), disposable
Indicated population Children under 8 years or weighing less than 25 kg (55 lb)
Energy reduction 200 J at the defibrillator → 50 J at the patient (integrated attenuator)
Supported shocks 50–100 J (paediatric series)
Cable length 120 cm, external (lead-out / preconnected)
Total surface (per electrode) 75 cm² (paediatric series)
Active surface (per electrode) 40 cm² (paediatric series)
Conductive gel Low-impedance conductive adhesive gel
Conductive material Metal foil
Backing material Medical foam (1 mm thick)
Connection type Specific safety anti-shock connector, external cable (lead-out)
ECG monitoring Max. 24 h
Use Single-use, disposable; latex- and phthalate-free
Presentation 1 pair in heat-sealed polyethylene and aluminium pouch; 5 pairs per box (paediatric series)
Shelf life Approx. 30 months from the production date (check the printed expiry date)
Classification Medical device class IIb (Directive 93/42/EEC; current catalogue compliant with MDR 2017/745)
Regulatory standard ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993

Compatible equipment:

Brand Compatible models
Cardiac Science Powerheart AED series 9200; Powerheart AED G3 series 9300 (G3, G3 Plus, G3 Pro); FirstSave AED G3 series 9300
General Electric (GE) GE Responder AED and GE Responder AED Pro

Technical note: the limited-energy function requires connection of the paediatric pad to the corresponding AED port; check the connector fit on your equipment before replacement and observe the expiry date printed on the packaging.

4. Equivalences and Cross-References

This electrode (SKU F7957WPL) is a consumable compatible with Cardiac Science Powerheart G3 and GE Responder AED / AED Pro defibrillators, not an original factory replacement. The correspondence with the equipment manufacturer’s references and with other brands in the sector is as follows; any comparison between brands should be understood as comparable at category level, not 1:1 interchangeable.

Manufacturer / Brand Family / Model Reference code / SKU Equivalence level Technical differences / Remarks
Cardiac Science (ZOLL) Powerheart Pediatric Pads (energy reduction ≈50 J) 9730-002 Comparable by category (not interchangeable 1:1) Original equipment manufacturer (OEM) reference for the same Powerheart G3 series 9200/9300 and GE Responder AED equipment: integrated attenuator at ≈50 J and original proprietary connector, for children under 8 years or <25 kg. Code verified with authorised distributors, ZOLL official store and GUDID.
GE (General Electric) Pediatric Attenuated Defibrillation Electrode Pads (Responder AED Pro) 2019199-003 Comparable by category (not interchangeable 1:1) OEM reference documented in the GE Responder AED Pro operator manual for patients under 8 years or <25 kg (Cardiac Science part under GE number); verify the equipment connector fit before any replacement.
ZOLL Medical Pedi-Padz II (paediatric AED Plus / AED Pro electrodes) 8900-0810-01 Comparable by category (not interchangeable 1:1) Same paediatric range (<8 years / <25 kg) and automatic switch to paediatric energy (50/70/85 J), but with ZOLL proprietary connector, algorithm and management electronics; exclusive to AED Plus and AED Pro.

No manufacturer-validated equivalence table authorises the replacement of original references 9730-002 / 2019199-003 with third-party pads: the connector, attenuator and analysis algorithm are proprietary. Any replacement must be validated against the defibrillator’s technical data sheet and IFU. Within the Cahnos catalogue there are comparable families for other equipment in the same category (paediatric AED electrodes with limited energy), such as F7950WPL (Philips), F7952WPL (Physio-Control), F7959WPL (CU Medical i-PAD) or F7966WPL (Defibtech), all comparable by category and not 1:1 interchangeable with each other. Consult the Cahnos technical department before use in tenders.

5. Selection tips and variants of interest

  • Confirm the equipment model: this electrode corresponds to Cardiac Science Powerheart series 9200, G3 series 9300 (G3, G3 Plus, G3 Pro), FirstSave G3 and GE Responder AED / AED Pro AEDs. It is not valid for other equipment with a different connector.
  • Check the reference and expiry date: verify the F7957WPL code and expiry date on the packaging; do not force the installation of an expired electrode (the gel may lose conductivity) nor reuse a pair after an intervention.
  • Paediatric provision: in centres with a child population always keep a pair of paediatric electrodes with the AED; the energy is reduced automatically when the limited-energy pad is connected, with no manual configuration.
  • Variants within the Cahnos catalogue: F7957PL (same paediatric family with 120 cm internal cable and the same 200 J → 50 J reduction) and, for other equipment, F7950WPL (Philips HeartStart FR2/FR2+), F7952WPL (Physio-Control LIFEPAK with pink connector), F7959WPL (CU Medical i-PAD NF1200/NF1201) and F7966WPL (Defibtech Lifeline), all with limited energy.
  • Maintenance: manage stock rotation by expiry date (approx. 30 months) and always replace the electrode after use or expiry. For volume orders or tenders, contact the Cahnos technical department stating the exact model and serial number of the equipment.

Additional information

Reference

F7957WPL

Brand family

EuroDefiPads (compatible with Cardiac Science / GE)

Product type

Limited-energy paediatric multifunction electrode, 1 disposable pair, external cable (lead-out)

Indicated population

Children under 8 years or weighing less than 25 kg (55 lb)

Total surface

75 cm² per electrode (paediatric series)

Active surface

40 cm² per electrode (paediatric series)

Supported shocks

50–100 J (paediatric series)

Conductive gel

Low-impedance conductive adhesive gel

Conductive material

Metal foil

Connection

Specific safety anti-shock connector, external cable (lead-out)

ECG monitoring

Max. 24 h

Presentation

1 pair in heat-sealed polyethylene and aluminium pouch; 5 pairs per box (paediatric series)

Use

Single-use, disposable; latex- and phthalate-free

Classification

Medical device class IIb (Directive 93/42/EEC; current catalogue compliant with MDR 2017/745)

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993

Shelf life

Approx. 30 months from the production date (check the printed expiry date)

Expiry

As indicated on the packaging; do not use after the expiry date

Sales format

Price per pair of electrodes

Family

EuroDefiPads

Electrode type

Limited-energy paediatric multifunction, 1 pair (2 pieces), disposable

Energy reduction

200 J at the defibrillator → 50 J at the patient (integrated attenuator)

Cable length

120 cm, external (lead-out / preconnected)

Total surface per electrode

75 cm² (paediatric series)

Active surface per electrode

40 cm² (paediatric series)

Backing material

Medical foam (1 mm thick)

Connection type

Specific safety anti-shock connector, external cable (lead-out)

Compatibility

Cardiac Science Powerheart AED series 9200; Powerheart AED G3 series 9300 (G3, G3 Plus, G3 Pro); FirstSave AED G3; GE Responder AED and GE Responder AED Pro