Description
1. Introduction
The TRAINER for iPAD CU-SPR (reference 35410) is the official training device for the iPAD CU-SPR semi-automatic defibrillator family. It is designed so that life support academies, emergency services, healthcare training departments and CPR instructors can train their staff and lay users in the use of the AED, reproducing the operation of the real clinical device but without delivering a shock: a safe, realistic and repeatable solution to equip a complete simulation classroom and meet training programmes in cardio-protected areas.
2. Technical explanation of the equipment
The TRAINER replicates the operational sequence of the semi-automatic defibrillator iPAD CU-SPR: it guides the student step by step with voice prompts, LED indicators and on-screen graphics throughout the entire rescue (rhythm analysis, simulated shock indication and cardiopulmonary resuscitation). The instructor can thus assess the student’s response in each scenario and correct the technique for placing the pads and compressions without any risk. The software allows the language of the prompts to be selected from multiple options (GB English, Italian, Danish, Norwegian, Swedish, Finnish, Hungarian, Ukrainian, Russian, Korean, Japanese, Hebrew, Thai and Arabic), making it especially useful for international training and multilingual environments. It is a purely educational device: it does not perform analysis or shocks on patients and must not be used as a substitute for a clinical defibrillator.
3. Technical Specifications
Product data
| Manufacturer | GIMA |
|---|---|
| Sales unit | 1 pc |
Simulator specifications
| Model / type | TRAINER for iPAD CU-SPR (training simulator) |
|---|---|
| Manufacturer reference | 35410 (SKU Cahnos: GM35410) |
| Clinical equipment replicated | Semi-automatic external defibrillator (AED) iPAD CU-SPR |
| Selectable software languages | GB, IT, DK, NO, SE, FI, HU, UA, RU, KR, JP, IL, TH and Arabic |
| Function | Reproduces the operational sequence, voice prompts and indications of the real AED for training |
| Electric discharge | Does not release energy (simulation and training only) |
| Use | CPR and AED use training; not suitable for clinical use or on patients |
4. Equivalences and Cross-References
Within the iPAD CU-SPR family, this TRAINER (35410) is the training version of the semi-automatic defibrillator iPAD CU-SPR (35400 and variant 35401), so both must be used in a coordinated manner in the classroom: the simulator for practice and the real device as a clinical reference. There is a variant of the same TRAINER with a different language package (35411). There is no manufacturer-validated equivalence table that would allow this simulator to be replaced by trainers from other brands: the interface, scenarios and protocols are proprietary to the iPAD CU-SPR/GIMA platform. Any comparison with simulators from other manufacturers (e.g. AED trainers from other brands) should be understood as comparable at category level, not interchangeable 1:1, and must be confirmed with the technical department of Cahnos before use in tenders.
5. Selection tips and variants of interest
Before placing the order, verify that the TRAINER’s language package matches that of your training programme: this reference (35410) includes GB, IT, DK, NO, SE, FI, HU, UA, RU, KR, JP, IL, TH and Arabic; if you need another combination of languages, consult variant 35411 or other available configurations. To set up a complete training classroom on the CU-SPR platform, combine the simulator with the reference semi-automatic defibrillator iPAD CU-SPR (35400 / 35401) and its supply of pads and training battery. Remember that this device is exclusively for teaching: it must not be used in real clinical interventions. For volume orders, academy supplies or tenders, contact the technical-commercial department of Cahnos to confirm languages, configuration and delivery times.





Reviews
There are no reviews yet.