We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Disposable compatible paediatric electrodes Philips Laerdal Medical (HeartStart FR2 AED) (Ref. 33606)

90,25 €

Set of disposable compatible paediatric electrodes for Philips Laerdal Medical defibrillators from the HeartStart FR2 AED family (M3841A, M3861A and versions with ECG module 3840A, 3860A). They include an energy reduction system from 150 J to 50 J, are indicated for patients up to 8 years (approximately 25 kg according to standard growth curves) and are latex-free. Manufactured in Italy as a Class II B medical device (EAN 8033695729323), in a 2-piece kit presentation with a multilingual pouch. Single-use consumable to keep your defibrillation unit equipped for a cardiorespiratory arrest in the paediatric population. For large orders you can request a quote: contact our technical-commercial team.

Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM33606

Description

1. Commercial Introduction

Keep your Philips Laerdal Medical defibrillator always ready to treat the youngest patients with this set of compatible paediatric electrodes (Ref. 33606, SKU Cahnos GM33606). It is a pair of single-use disposable pads, with a connector specific to the HeartStart FR2 AED platform, designed for cardioprotected spaces, ambulances, emergency services, schools and facilities equipped with these devices. An essential consumable to complete the paediatric capability of your AED without the need to purchase a second device.

2. Technical explanation of the equipment and procedure

The defibrillation electrodes or pads are the interface element between the defibrillator and the patient: through them, the device analyses the cardiac rhythm and delivers the transthoracic shock needed to reverse a life-threatening arrhythmia such as ventricular fibrillation. In the paediatric population (children under 8 years or approximately 25 kg according to standard growth curves), the energy delivered must be reduced to avoid myocardial damage.

This set incorporates an energy reduction system that converts the defibrillator’s 150 J output into a 50 J shock, suitable for paediatric treatment. They are disposable pads: they must be replaced after each use or upon reaching the expiry date printed on the packaging, and must never be used if the protective pouch is damaged, as the conductive gel may lose conductivity. They are latex-free and manufactured in Italy.

3. Technical specifications and tables

3.1. Available references

Reference Model Sales unit
GM33606 (33606) Compatible paediatric electrodes for Philips Laerdal Medical defibrillator (see also 55006) Kit of 2 units

3.2. Product data

Field Value
Manufacturer GIMA
Sales unit Kit of 2 units
Device type Medical device
Device class II B
CND C020401
GMDN 47055
EAN 8033695729323

3.3. Main features

Parameter Specification
Target population Paediatric: up to 8 years (approx. 25 kg according to standard growth curves)
Energy reduction system 150 J (defibrillator output) → 50 J delivered
Use Disposable, single-use
Allergenic Latex-free
Manufacture Made in Italy
Packaging Multilingual envelope: GB, FR, IT, ES, PT, DE, NL, SE, GR, RU
Conformity It complies internationally with the applicable regulations, as do the compatible adult pads.

3.4. Compatibility with defibrillators

Manufacturer Compatible models
Philips Laerdal Medical HeartStart FR2 AED M3841A and M3861A
Philips Laerdal Medical HeartStart FR2 AED with ECG module: 3840A, M3861A, 3860A

Note: always verify the exact model of your device and the correct fit of the connector into the electrode socket before clinical use.

4. Equivalences and Cross-References

This product corresponds to reference 33606, marketed by Cahnos as GM33606. The manufacturer lists as an associated reference the compatible adult pads for the same Philips Laerdal Medical platform (ref. 55006, “see also 55006”), with which it shares the connector and platform, differing in the target population and in the energy reduction system.

Within the same manufacturer’s catalogue, other pairs of paediatric electrodes compatible with other defibrillator platforms are documented: the paediatric pads for Medtronic Physio Control (Lifepak 500 AED with pink connector, Lifepak 1000 AED, Lifepak CR Plus AED and Lifepak Express AED; Ref. 33603, SKU Cahnos GM33603, with reduction from 200 J to 50 J) and the paediatric pads for Cardiac Science and GE (Powerheart AED 9200 series, G3 9300 series and GE Responder AED / AED Pro; Refs. 33604 and 55002). There is no manufacturer-validated equivalence table cross-referencing this reference with original Philips electrodes: this is a compatible consumable, not an original spare part certified by the device manufacturer. For comparisons or tenders, consult the technical department at Cahnos.

5. Selection tips and variants of interest

Verify the platform: this set is exclusive to Philips Laerdal HeartStart FR2 AED defibrillators (M3841A, M3861A and versions with ECG module 3840A, 3860A). If your equipment fleet includes other brands, consider the paediatric pairs for Medtronic Physio Control (GM33603) or for Cardiac Science/GE (GM33604). Confirm the target population: these pads are paediatric; for patients over 8 years or over 25 kg, use the adult electrodes compatible with your platform (e.g., the associated reference 55006). Plan replacement: as this is a single-use consumable, it is recommended to keep at least one spare set for each defibrillation unit, manage stock using FIFO rotation and respect the expiry date printed on the packaging; never reuse pads after a shock. For large orders you can request a quote: contact Cahnos’s technical-commercial team, indicating the exact model of your defibrillator, to formalise your quotation.

Additional information

Sales unit

kit of 2 pcs

Manufacturer reference

33606

Patient type

Paediatric (up to 8 years / approx. 25 kg)

Energy reduction system

150 J → 50 J

Use

Disposable, single-use

Unit of sale

Kit of 2 units

Manufacture

Made in Italy

Packaging

Multilingual envelope: GB, FR, IT, ES, PT, DE, NL, SE, GR, RU

Compatibility

Philips Laerdal Medical: HeartStart FR2 AED M3841A and M3861A; with ECG module 3840A, M3861A, 3860A

CND code

C020401

GMDN code

47055

EAN

8033695729323

Tipo dispositivo

Medical device

Clase sanitaria

II b

Latex

Latex-free

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesDownload PDF

Reviews

There are no reviews yet.

Be the first to review “Disposable compatible paediatric electrodes Philips Laerdal Medical (HeartStart FR2 AED) (Ref. 33606)”

Your email address will not be published. Required fields are marked *