We use our own and third-party cookies to analyse the use of the website and show you advertising related to your preferences, based on a profile built from your browsing habits (for example, pages visited). More information

Cahnos.com Compare invoice

Compatible paediatric electrodes for Philips Laerdal Medical HeartStart FR2 defibrillator – Reduced energy 150 J / 200 J to 50 J – Ref. 55006 (Single-use)

361,00 €

Disposable paediatric electrodes compatible with the Philips Laerdal Medical HeartStart FR2 AED (M3841A and M3861A) and HeartStart FR2 AED with ECG module (3840A, M3861A, 3860A). They incorporate an energy reduction system that attenuates the device output from 150 J (ref. 33606) or 200 J (ref. 33603) to 50 J at the patient, the dose recommended by CPR guidelines for paediatric treatment (up to 8 years, equivalent to approximately 25 kg according to standard growth curves). Multilingual packaging, latex-free and manufactured in Italy. Presentation: 5 pairs.

Sales unit: 5 pares
Minimum order for products shipped from Italy: 150,00 € excluding VAT (can be combined)

Delivery time: 15 days

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM55006

Description

1. Commercial Introduction

Ensure the safe care of the smallest patients with these compatible paediatric electrodes, the ideal replacement solution for the Philips Laerdal Medical defibrillators of the HeartStart FR2 and FR2+ family. Designed as a disposable paediatric pad, they keep your AED ready to act in paediatric cardiac arrest in schools, nurseries, paediatric practices, ambulances and cardio-protected spaces with children present. They are sold in packs of 5 pairs, with multilingual packaging and manufactured in Italy.

2. Technical explanation of the equipment and procedure

Disposable multifunction electrodes are the interface between the defibrillator and the patient: through them the device analyses the rhythm, delivers the shock and monitors the electrocardiographic response. In paediatric patients it is essential to attenuate the delivered energy to avoid myocardial injury; international CPR guidelines set 8 years as the age limit for paediatric treatment, which corresponds to approximately 25 kg according to standard growth curves.

These pads incorporate an energy reduction system: the defibrillator output of 150 J (ref. 33606) or 200 J (ref. 33603) is reduced to 50 J at the patient, delivering a dose adapted to paediatric physiology. They comply with applicable international regulations, just like the compatible adult pads. They are single-use, latex-free and manufactured in Italy.

3. Technical Specifications

Product data

Manufacturer GIMA
Sales unit 5 pairs
Device type Medical device
Device class II B
CND C020401
GMDN 47055

Available references

SKU Cahnos GM55006
Manufacturer reference 55006

Technical features

Target population Paediatric: up to 8 years (approx. 25 kg according to standard growth curves)
Energy reduction system Reduces the defibrillator output from 150 J (33606) or 200 J (33603) to 50 J
Use Single-use (disposable)
Latex Latex-free
Manufacture Italy
Packaging Multilingual: GB, FR, IT, ES, PT, DE, NL, SE, GR, RU

Compatibility with defibrillators

Brand / Family Model
Philips Laerdal Medical HeartStart FR2 AED – M3841A and M3861A
Philips Laerdal Medical HeartStart FR2 AED, with ECG module – 3840A, M3861A, 3860A

Note: always verify the exact model of the device and the fit of the connector before use.

4. Equivalences and Cross-References

This electrode (SKU GM55006, manufacturer ref. Ref. 55006) is a paediatric consumable compatible with the HeartStart FR2/FR2+ family. Any comparison with other brands should be understood as comparable at category level, not interchangeable 1:1, verifying connector, energy range and algorithm before any replacement.

Manufacturer / Brand Product Reference Equivalence level Observations
Philips Healthcare Infant/Child Reduced-Energy Defibrillator Pads (HeartStart FR2 / FR2+) M3870A (also 989803108851) Comparable by category (not interchangeable 1:1) Original manufacturer replacement for FR2 (M3840A/M3841A) and FR2+ (M3860A/M3861A); same energy reduction from 150 J to 50 J. Code verified in GUDID (UDI-DI 00884838023734) and on the official Philips website.
Cahnos (own catalogue) Paediatric AED electrodes with limited energy – Philips family F7950WPL Comparable by category (not interchangeable 1:1) Same family of limited-energy paediatric electrodes for Philips devices; verify exact model and connector.

There is no equivalence table validated by the manufacturer for this reference; consult the technical department of Cahnos before using in a tender.

5. Selection tips and variants of interest

  • Confirm the device model: verify that you have a Philips Laerdal Medical HeartStart FR2 AED (M3841A, M3861A) or HeartStart FR2 AED with ECG module (3840A, M3861A, 3860A) and that the connector fits correctly into the electrode socket.
  • Paediatric population: these pads are for children up to 8 years (approx. 25 kg). For adult patients use the adult pads corresponding to your device.
  • Automatic reduced energy: the integrated reduction system attenuates the shock from 150 J (33606) or 200 J (33603) to 50 J, without manual configuration.
  • Variants within the Cahnos catalogue: for defibrillator-monitors of the Philips / Agilent Hewlett-Packard / Laerdal Medical family (CodeMaster 100, XE, XL, XL+ and HeartStart 4000) the references F7953P (internal cable) and F7953PW (external cable) are available.
  • Storage and expiry: check the date printed on the packaging and store in a dry place; do not use expired electrodes or those with damaged packaging, as the gel may lose conductivity. As they are single-use, replace the pair after each use.

Additional information

Sales unit

5 pairs

Manufacturer reference

55006

Product type

Pair of disposable paediatric electrodes with energy reduction system

Target population

Paediatric (up to 8 years / approx. 25 kg)

Energy reduction system

Reduces the defibrillator output from 150 J (33606) or 200 J (33603) to 50 J

Compatibility

Philips Laerdal Medical – HeartStart FR2 AED (M3841A, M3861A) and HeartStart FR2 AED with ECG module (3840A, M3861A, 3860A)

Unit of sale

5 pairs

Use

Single-use (disposable)

Packaging

Multilingual (GB, FR, IT, ES, PT, DE, NL, SE, GR, RU)

CND code

C020401

GMDN code

47055

Tipo dispositivo

Medical device

Clase sanitaria

II b

Latex

Latex-free

Pais fabricacion

Italy

Documentation

📄 DatasheetEnglish PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesDownload PDF

Reviews

There are no reviews yet.

Be the first to review “Compatible paediatric electrodes for Philips Laerdal Medical HeartStart FR2 defibrillator – Reduced energy 150 J / 200 J to 50 J – Ref. 55006 (Single-use)”

Your email address will not be published. Required fields are marked *