Compatible disposable adult/paediatric electrodes for defibrillators Mediana HeartOn AED A15 and Tecno-Gaz Tecnoheart Plus (Ref. GM33584)

Price range: 53,20 € through 408,50 €

Set of compatible disposable adult/paediatric electrodes (pair of pads with cable and connector) for defibrillators Mediana HeartOn AED A15 and Tecno-Gaz Tecnoheart Plus (patient >10 kg). Manufactured in Italy, BSI certified and compliant with Directive 93/42/EEC as a class IIb medical device. Excellent adhesion, adequate gel thickness and latex-free. Reference GM33584 (kit of 2 units); also available reference GM55046 in a box of 10 pairs for stock management.

International shipping. Import duties and taxes are payable by the recipient.

Reference
GM33584-F

Description

1. Commercial Introduction

Keep your defibrillator Mediana HeartOn AED A15 or Tecno-Gaz Tecnoheart Plus always operational with these compatible electrodes, the essential consumable for treating both adult and paediatric patients in cardiorespiratory arrest. They are a pair of disposable pads with cable and connector ready to connect to the device, designed for cardioprotected spaces, health centres, ambulances and emergency units equipped with these manufacturers.

2. Technical explanation of the equipment and procedure

The defibrillation electrodes or pads are the interface element between the defibrillator and the patient: through them the device analyses the cardiac rhythm and delivers the transthoracic shock necessary to reverse a fatal arrhythmia. In paediatric patients, international CPR guidelines set the age limit for paediatric treatment at 8 years, which corresponds approximately to 25 kg according to standard growth curves; this set covers that range and, furthermore, the referenced models accept patients from >10 kg. The pad offers excellent adhesion and an adequate gel thickness that guarantee stable contact, correct impedance and effective energy transfer during resuscitation. They are single-use and disposable: they must be replaced after each intervention or upon reaching the expiry date printed on the packaging.

3. Technical Specifications

Parameter Specification
Manufacturer GIMA
Device type Medical device (Medical device)
Device class II B
CND C020401
Target population Adult and paediatric (>8 years / ±25 kg); compatible with patient >10 kg
Contents One pair of pads, cable and connector
Format Disposable, single-use
Maximum shelf life 30 months (24 months for ref. 33584) from the date of production
Allergenic Latex-free
Production Made in Italy (Made in Italy)
Packaging Multilingual envelope: GB, FR, IT, ES, PT, DE, NL, SE, GR, RU
Reference standards ANSI/AAMI: DF-80; IEC/EN: 60601-1, 60601-2-4; ISO: 10993-1
Conformity Directive 93/42/EEC and amendments; class IIb medical device

Available references

Reference Model Sales unit
GM33584 see also 55046 Kit of 2 units
GM55046 Compatible electrodes for defibrillator Mediana, Tecno-Gaz 10 pairs

Compatibility with defibrillators

Manufacturer Models Patient
Mediana HeartOn AED A15 >10 kg
Tecno-Gaz Tecnoheart Plus >10 kg

4. Equivalences and Cross-References

Within the catalogue, reference GM33584 is supplied as a kit of 2 pieces and finds its equivalent in the larger presentation GM55046 (box of 10 pairs), which corresponds to the same electrode (manufacturer’s original SKU 33584 / 55046). No officially validated equivalences with the original pad references from Mediana or Tecno-Gaz are published in the source, so substitution must always be validated against the technical data sheet and the defibrillator manual (connector, algorithm and energy management are proprietary to each manufacturer).

5. Selection tips and variants of interest

Confirm the exact model of your device and that the connector of these electrodes fits correctly into the defibrillator socket before clinical use. Remember that in paediatric resuscitation the age limit is 8 years (≈25 kg) and that these pads cover patients >10 kg according to the indications of the compatible models. As it is a single-use consumable, plan its replacement in duplicate per defibrillation unit and rotate stock according to the expiry date (30 months, or 24 months for ref. 33584). For provisions or volume orders, reference GM55046 (10 pairs) is the recommended presentation. In the Cahnos catalogue, compatible electrodes are available for other defibrillators on the market (Mediana HeartOn AED A10, Agilent-Philips, Defibtech, Nihon Kohden, Cardiac Science/GE, Drager-Innomed-S&W-Welch Allyn, among others); consult the Cahnos technical department indicating the exact model and serial number of your device.

Additional information

Modelo

see also 55046, COMPATIBLE PADS for defibrillator Mediana, Tecno-Gaz

Manufacturer reference

33584 / 55046

Device type

Medical device (Medical device)

CND code

C020401

Target population

Adult and paediatric (>8 years / ±25 kg); patient >10 kg

Compatibility

Mediana HeartOn AED A15; Tecno-Gaz Tecnoheart Plus (patient >10 kg)

Presentation

Kit of 2 units (GM33584); box of 10 pairs (GM55046)

Contents

Pair of pads, cable and connector

Usage type

Disposable, single-use

Shelf life

30 months (24 months for ref. 33584) from production

Production

Italy

Regulatory standard

ANSI/AAMI DF-80; IEC/EN 60601-1, 60601-2-4; ISO 10993-1

Conformity

Directive 93/42/EEC and amendments; class IIb

Certifications

BSI

Tipo dispositivo

Medical device

Clase sanitaria

II b

Latex

Latex-free

Documentation

📄 DatasheetEnglish PDF
📎 Label / packagingLabel Box PDF
📜 Declaration of conformityEnglish PDF
📜 CE certificateDownload PDF
📜 ISO 9001 / 13485 certificatesDownload PDF