1. Commercial Introduction
The iPad CU-SP1 – automatic is the latest generation of intelligent public-access automated external defibrillators (AEDs), designed to provide an immediate and safe response to cardiac arrest. It is the ideal equipment for businesses, schools, sports centres, public facilities, clinics and emergency services that need a high-performance, easy-to-use device with minimal maintenance.
Thanks to its fully automatic operation, once connected to the patient the device analyses the electrocardiogram and, if it detects a shockable rhythm, it charges itself and delivers the shock without any intervention from the rescuer: you only need to follow the voice instructions, the light indicators and the graphics that guide the entire rescue procedure, including CPR compressions.
2. Technical explanation of the equipment and procedure
The CU-SP1 is an automated external defibrillator (AED) that, connected to the patient via multifunction electrodes, acquires and analyses the electrocardiogram (ECG) to detect the presence of ventricular fibrillation or ventricular tachycardia (shockable rhythms). If a shockable rhythm is detected, the device charges automatically and, once charging is complete, delivers the electric shock automatically, without the rescuer having to press any button.
It incorporates innovative functions to maximise the chances of survival:
- Automatic volume adjustment: detects ambient noise and adjusts the volume of the instructions so that they are always audible.
- Smart electrodes (Smart pads): the pre-connected electrodes are stored in a quick-access compartment at the bottom; the front indicator shows whether they are within their service life and warns when there are 3 months left before expiry.
- CPR detection: the device detects whether resuscitation is being performed and, if not, encourages the rescuer to perform it.
- Communication with CU-EX1 software: allows reviewing and analysing the device’s usage history (power-on time, heart rhythm and delivered shocks).
3. Technical Specifications
Defibrillator
| Operating mode | Fully automatic |
| Waveform | biphasic e-Cube (truncated exponential type) |
| Energy | Adult: nominal 150 J between 25 and 175 ohm; Paediatric: nominal 50 J at 50 ohm |
| Charge control | Controlled by the automatic patient analysis system |
| Weight-bearing time | In less than 10 seconds from the voice instruction |
| Protection | Resistant to water jet IPX5 and dust IP5X according to IEC 60529 (IP55) |
| Dimensions and weight | 260 x 256 x 69.5 mm – 2.4 kg (includes electrodes and battery) |
User interface
| User support | Detailed voice instructions and flashing light indicators |
| CPR guidance | Voice instructions for performing CPR on adults and children |
| Controls | On/off button and “i” button |
| Indicator | LCD screen (device status, battery status, electrode status) |
| Detection | Electrode expiry date and electrode connection status |
Data recording and transmission
| Ports | IrDA port / SD card for PC communication |
| Internal memory | Multiple recording: 5 individual events / maximum 3 hours |
| Review software | CU-EX1 (for PC) |
Patient analysis system
| Analysis | Shockable rhythms: ventricular fibrillation and ventricular tachycardia |
| Sensitivity/specificity | Complies with AAMI DF80 guideline |
High-capacity disposable battery
| Type | Standard: DC 12 V 4.2 Ah, lithium manganese dioxide |
| Capacity | Minimum 200 shocks or 8 hours of operation |
Operating altitude range
| Altitude | 0–4,570 m (0–15,000 ft) |
Available references
| Reference | Language | Sales unit |
|---|---|---|
| GM35338 | GB, SE, FI, NO, DK, LT, PL, CZ, UA, KR (specify language when ordering) | 1 pc |
| GM35339 | GB, FR, IT, ES, PT, DE, NL, GR, US, KR (specify language when ordering) | 1 pc |
Voice software: US, PL, CZ, DK, SE, FI, NO, LT, UA, KR. Online manual: GB, CZ, DK, SE, NO, KR (*languages included only in “Voice” have an English manual). Paper manual only for GB, IT.
Included accessories
- Adult electrodes
- Carry bag
- Disposable lithium battery pack
- Paper manual (GB, IT)
Product data
| Manufacturer | GIMA |
|---|---|
| Model | CU-SP1 – automatic |
| Sales unit | 1 pc |
| Device type | Medical device (medical device) |
| Device class | II B |
4. Equivalences and Cross-References
The iPad CU-SP1 is the fully automatic version of the public-access defibrillator family that it distributes, together with the semi-automatic variant of the same platform. The manufacturer’s catalogue references are 35338 and 35339, which differ only in the software and manual languages included.
Within the Cahnos catalogue, the consumables and spare parts related to this family of CU Medical Systems (i-PAD) equipment include: GM33441 (disposable adult electrodes for i-PAD), the battery CUSA0601F (12 V / 4.2 Ah, original i-PAD reference, available at Cahnos as 88888831) and the limited-energy paediatric electrodes from the compatible series. There is no 1:1 equivalence table validated by the manufacturer that authorises third-party spare parts for this device: the connector, the analysis algorithm and the energy management are proprietary to the platform; always verify exact compatibility with the model and reference before replacement.
5. Selection tips and variants of interest
Confirm the reference and language: the GM35338 reference includes voice software in GB, SE, FI, NO, DK, LT, PL, CZ, UA, KR, and the GM35339 in GB, FR, IT, ES, PT, DE, NL, GR, US, KR. Specify the desired voice language when placing the order.
Scheduled maintenance: periodically check the front indicator of the smart electrodes (which warns when 3 months of life remain) and the battery status using the device’s self-tests; replace consumables before their expiry date with FIFO stock rotation.
Complete provision: always keep a pair of adult electrodes operational and in date and, if attending to children, provide the reduced-energy paediatric electrodes suitable for this platform, together with the spare battery (original reference CUSA0601F).
Data analysis: with the CU-EX1 software you can review the device’s usage and shock history, useful for audits and protocol improvement. For volume orders, tenders or defibrillator fleets, contact the Cahnos technical department indicating the exact model and the necessary references.